Study on Calibration of Chromlum(VI) Analyzer

This article presents a novel metrological calibration method for trace chromium(VI) analyzer. The study identifies all factors that affect the accuracy of chromium(VI) analyzers, and proposes calibration items and method for the analyzer based on its working principle. The calibration items include...

Full description

Bibliographic Details
Main Authors: Peng Jianchun, Li Xianhong, Liu Ying, Ren Tingting, Mo Hongbo
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/22/e3sconf_isesce2023_02020.pdf
_version_ 1797829404590604288
author Peng Jianchun
Li Xianhong
Liu Ying
Ren Tingting
Mo Hongbo
author_facet Peng Jianchun
Li Xianhong
Liu Ying
Ren Tingting
Mo Hongbo
author_sort Peng Jianchun
collection DOAJ
description This article presents a novel metrological calibration method for trace chromium(VI) analyzer. The study identifies all factors that affect the accuracy of chromium(VI) analyzers, and proposes calibration items and method for the analyzer based on its working principle. The calibration items include pump set flow error and pump flow stability, set temperature error and temperature control stability of column oven, baseline noise and drift, minimum detection concentration, linear range, and qualitative and quantitative repeatability. Experimental results shows that, the presented method can meet the requirements for the metrological performance evaluation of chromium(VI) analyzer. The calibration method is scientific and feasible.
first_indexed 2024-04-09T13:19:51Z
format Article
id doaj.art-55ce25a279d34093b9df9f10ea9af075
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-04-09T13:19:51Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-55ce25a279d34093b9df9f10ea9af0752023-05-11T09:09:12ZengEDP SciencesE3S Web of Conferences2267-12422023-01-013850202010.1051/e3sconf/202338502020e3sconf_isesce2023_02020Study on Calibration of Chromlum(VI) AnalyzerPeng Jianchun0Li Xianhong1Liu Ying2Ren Tingting3Mo Hongbo4Chongqing Academy of Metrology and Quality InspectionChongqing Academy of Metrology and Quality InspectionChongqing Academy of Metrology and Quality InspectionChongqing Academy of Metrology and Quality InspectionChongqing Academy of Metrology and Quality InspectionThis article presents a novel metrological calibration method for trace chromium(VI) analyzer. The study identifies all factors that affect the accuracy of chromium(VI) analyzers, and proposes calibration items and method for the analyzer based on its working principle. The calibration items include pump set flow error and pump flow stability, set temperature error and temperature control stability of column oven, baseline noise and drift, minimum detection concentration, linear range, and qualitative and quantitative repeatability. Experimental results shows that, the presented method can meet the requirements for the metrological performance evaluation of chromium(VI) analyzer. The calibration method is scientific and feasible.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/22/e3sconf_isesce2023_02020.pdf
spellingShingle Peng Jianchun
Li Xianhong
Liu Ying
Ren Tingting
Mo Hongbo
Study on Calibration of Chromlum(VI) Analyzer
E3S Web of Conferences
title Study on Calibration of Chromlum(VI) Analyzer
title_full Study on Calibration of Chromlum(VI) Analyzer
title_fullStr Study on Calibration of Chromlum(VI) Analyzer
title_full_unstemmed Study on Calibration of Chromlum(VI) Analyzer
title_short Study on Calibration of Chromlum(VI) Analyzer
title_sort study on calibration of chromlum vi analyzer
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/22/e3sconf_isesce2023_02020.pdf
work_keys_str_mv AT pengjianchun studyoncalibrationofchromlumvianalyzer
AT lixianhong studyoncalibrationofchromlumvianalyzer
AT liuying studyoncalibrationofchromlumvianalyzer
AT rentingting studyoncalibrationofchromlumvianalyzer
AT mohongbo studyoncalibrationofchromlumvianalyzer