Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit

Laboratory unit was designed to simulate (T2) line in Alrustamyia station for sewage treatment southern part of Baghdad city . The work involved two stages, before and after prearation tank and primary settling tank. Storage wastewater samples problem was overcome through using rotary cooling system...

Full description

Bibliographic Details
Main Author: Ali. S.Ahmed
Format: Article
Language:English
Published: Unviversity of Technology- Iraq 2013-04-01
Series:Engineering and Technology Journal
Subjects:
Online Access:https://etj.uotechnology.edu.iq/article_84150_002f884de66e4d5ad3b77664acae20f4.pdf
_version_ 1827358544339402752
author Ali. S.Ahmed
author_facet Ali. S.Ahmed
author_sort Ali. S.Ahmed
collection DOAJ
description Laboratory unit was designed to simulate (T2) line in Alrustamyia station for sewage treatment southern part of Baghdad city . The work involved two stages, before and after prearation tank and primary settling tank. Storage wastewater samples problem was overcome through using rotary cooling system at 2 C . The encouraging results obtained from previous work (new chemical treatment of prearated wastewater) were employed for the completion of our continuous feeding experiments on a laboratory unit scale . The flow rate was used as a control factor for monitoring the concentration of pollutants in the treated wastewater treated . The selected flow rate included the basic design flow rate of the T2 line (1X) and new flow rates (2X and 4X). The our new techniques involved the continuous feeding were reduced the concentrations ofBiological Oxygen Demand (BOD), Total Suspended Solid (TSS), liberated the entrapped oil and greases as well as reducing other pollutants. It was found that 2X flow rate was the best flow rate which doubled the quantity of wastewater treated and reduced the resident time of treatment to the half.
first_indexed 2024-03-08T06:12:22Z
format Article
id doaj.art-5624c2fcd2784ace937f3d0e4f2713ee
institution Directory Open Access Journal
issn 1681-6900
2412-0758
language English
last_indexed 2024-03-08T06:12:22Z
publishDate 2013-04-01
publisher Unviversity of Technology- Iraq
record_format Article
series Engineering and Technology Journal
spelling doaj.art-5624c2fcd2784ace937f3d0e4f2713ee2024-02-04T17:34:57ZengUnviversity of Technology- IraqEngineering and Technology Journal1681-69002412-07582013-04-01314 B41041810.30684/etj.31.4B.184150Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory UnitAli. S.AhmedLaboratory unit was designed to simulate (T2) line in Alrustamyia station for sewage treatment southern part of Baghdad city . The work involved two stages, before and after prearation tank and primary settling tank. Storage wastewater samples problem was overcome through using rotary cooling system at 2 C . The encouraging results obtained from previous work (new chemical treatment of prearated wastewater) were employed for the completion of our continuous feeding experiments on a laboratory unit scale . The flow rate was used as a control factor for monitoring the concentration of pollutants in the treated wastewater treated . The selected flow rate included the basic design flow rate of the T2 line (1X) and new flow rates (2X and 4X). The our new techniques involved the continuous feeding were reduced the concentrations ofBiological Oxygen Demand (BOD), Total Suspended Solid (TSS), liberated the entrapped oil and greases as well as reducing other pollutants. It was found that 2X flow rate was the best flow rate which doubled the quantity of wastewater treated and reduced the resident time of treatment to the half.https://etj.uotechnology.edu.iq/article_84150_002f884de66e4d5ad3b77664acae20f4.pdfsewageprearation tankprimary settling tankmodified chemical treatmentlaboratory system
spellingShingle Ali. S.Ahmed
Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit
Engineering and Technology Journal
sewage
prearation tank
primary settling tank
modified chemical treatment
laboratory system
title Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit
title_full Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit
title_fullStr Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit
title_full_unstemmed Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit
title_short Additional Processes in Prearation Tank and Primary Settling Tank for Wastewater Treatment Using Laboratory Unit
title_sort additional processes in prearation tank and primary settling tank for wastewater treatment using laboratory unit
topic sewage
prearation tank
primary settling tank
modified chemical treatment
laboratory system
url https://etj.uotechnology.edu.iq/article_84150_002f884de66e4d5ad3b77664acae20f4.pdf
work_keys_str_mv AT alisahmed additionalprocessesinprearationtankandprimarysettlingtankforwastewatertreatmentusinglaboratoryunit