Audit on titanium reconstruction of mandibular defects for jaw lesions

Aims: The aim of the study is to audit the titanium reconstruction of jaw defects in benign conditions in Christian Medical College and Hospital , Vellore. Methods and Material: A retrospective study of titanium reconstruction of mandibular defects due to jaw lesions at Christian Medical College and...

Full description

Bibliographic Details
Main Authors: S Arun Paul, A Kaneesh Karthik, Rabin Chacko, Whinny Karunya
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2014-01-01
Series:Journal of Pharmacy and Bioallied Sciences
Subjects:
Online Access:http://www.jpbsonline.org/article.asp?issn=0975-7406;year=2014;volume=6;issue=5;spage=39;epage=43;aulast=Paul
Description
Summary:Aims: The aim of the study is to audit the titanium reconstruction of jaw defects in benign conditions in Christian Medical College and Hospital , Vellore. Methods and Material: A retrospective study of titanium reconstruction of mandibular defects due to jaw lesions at Christian Medical College and Hospital, Vellore, India, between May 2008 and May 2011. Results: Mouth opening, facial symmetry, occlusion, chewing ability, plate exposure and patient satisfaction were used as outcome measures. Conclusions: The three-dimensional titanium plate is a reasonable material for immediate mandible reconstruction after surgical resection of benign jaw pathologies.