Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire

Introduction: The health and integrity of the dental pulp following orthodontic therapy is of major importance for tooth survival. EPT is a conventional method for evaluation of pulp vitality. Aim: The aim of the study was to evaluate sensibility of the dental pulp to EPT in the teeth under fixed or...

Full description

Bibliographic Details
Main Authors: Elham Khoshbin, Sepideh SohEilifar, Zakiyeh Donyavi, Nazanin Shahsavand
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2019-01-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/12459/37722_CE[Ra1]_F(SHU)_PF1(AB_SL)_PN(SL).pdf
_version_ 1819212146645401600
author Elham Khoshbin
Sepideh SohEilifar
Zakiyeh Donyavi
Nazanin Shahsavand
author_facet Elham Khoshbin
Sepideh SohEilifar
Zakiyeh Donyavi
Nazanin Shahsavand
author_sort Elham Khoshbin
collection DOAJ
description Introduction: The health and integrity of the dental pulp following orthodontic therapy is of major importance for tooth survival. EPT is a conventional method for evaluation of pulp vitality. Aim: The aim of the study was to evaluate sensibility of the dental pulp to EPT in the teeth under fixed orthodontic treatment with 0.014 and 0.012 initial NiTi archwire. Materials and Methods: In this study, 516 teeth (maxillary central and lateral incisors) were studied prospectively in 129 patients assigned to three groups: the 0.012 NiTi archwire, the 0.014 NiTi archwire and the control group. The aligning forces were administered using initial NiTi archwires of 0.012 and 0.014 ligated on fixed appliances by using the MBT straight wire technique. Stimulation of electrical sensibility threshold was done by EPT and was measured pre-bonding (EPT0), immediately upon initiation (EPT1) and one month post orthodontic therapy (EPT2). The data were analysed by paired sample t-test and one-way ANOVA test (p<0.05). Results: The mean values of sensibility threshold for all the experimental and control maxillary incisors at EPT0, EPT1, and EPT2 times were 28.5, 40.8, and 38.0, and 23.2, 23.5, and 22.7 units respectively. The mean values of sensibility threshold for all experimental teeth at EPT0, EPT1 and EPT2 times were statistically different by using Paired sample t-test (p<0.05). Statistical analysis using one-way ANOVA shows that there is a statistically significant difference between sensibility threshold when groups were compared with the control group (p<0.05). Conclusion: Following application of orthodontic forces, physiological changes of the dental pulp could affect the neural response. Response thresholds to electrical stimulation are also increased and consequently the EPT may not initiate a response. This finding is not an indication of loss of pulp vitality because after a few weeks the response threshold decreases. Therefore, the results of electrical pulp testing need to be carefully interpreted and closely scrutinised in orthodontics.
first_indexed 2024-12-23T06:38:20Z
format Article
id doaj.art-5693026717bf43e4930a10b18db1ca3a
institution Directory Open Access Journal
issn 2249-782X
0973-709X
language English
last_indexed 2024-12-23T06:38:20Z
publishDate 2019-01-01
publisher JCDR Research and Publications Private Limited
record_format Article
series Journal of Clinical and Diagnostic Research
spelling doaj.art-5693026717bf43e4930a10b18db1ca3a2022-12-21T17:56:44ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2019-01-01131ZC16ZC1910.7860/JCDR/2019/37722.12459Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi ArchwireElham Khoshbin0Sepideh SohEilifar1Zakiyeh Donyavi2Nazanin Shahsavand3Assistant Professor, Department of Endodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.Assistant Professor, Department of Endodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.Assistant Professor, Department of Endodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.Resident, Department of Endodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.Introduction: The health and integrity of the dental pulp following orthodontic therapy is of major importance for tooth survival. EPT is a conventional method for evaluation of pulp vitality. Aim: The aim of the study was to evaluate sensibility of the dental pulp to EPT in the teeth under fixed orthodontic treatment with 0.014 and 0.012 initial NiTi archwire. Materials and Methods: In this study, 516 teeth (maxillary central and lateral incisors) were studied prospectively in 129 patients assigned to three groups: the 0.012 NiTi archwire, the 0.014 NiTi archwire and the control group. The aligning forces were administered using initial NiTi archwires of 0.012 and 0.014 ligated on fixed appliances by using the MBT straight wire technique. Stimulation of electrical sensibility threshold was done by EPT and was measured pre-bonding (EPT0), immediately upon initiation (EPT1) and one month post orthodontic therapy (EPT2). The data were analysed by paired sample t-test and one-way ANOVA test (p<0.05). Results: The mean values of sensibility threshold for all the experimental and control maxillary incisors at EPT0, EPT1, and EPT2 times were 28.5, 40.8, and 38.0, and 23.2, 23.5, and 22.7 units respectively. The mean values of sensibility threshold for all experimental teeth at EPT0, EPT1 and EPT2 times were statistically different by using Paired sample t-test (p<0.05). Statistical analysis using one-way ANOVA shows that there is a statistically significant difference between sensibility threshold when groups were compared with the control group (p<0.05). Conclusion: Following application of orthodontic forces, physiological changes of the dental pulp could affect the neural response. Response thresholds to electrical stimulation are also increased and consequently the EPT may not initiate a response. This finding is not an indication of loss of pulp vitality because after a few weeks the response threshold decreases. Therefore, the results of electrical pulp testing need to be carefully interpreted and closely scrutinised in orthodontics.https://jcdr.net/articles/PDF/12459/37722_CE[Ra1]_F(SHU)_PF1(AB_SL)_PN(SL).pdfmaxillary incisorsorthodontic forcespulp tissue
spellingShingle Elham Khoshbin
Sepideh SohEilifar
Zakiyeh Donyavi
Nazanin Shahsavand
Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire
Journal of Clinical and Diagnostic Research
maxillary incisors
orthodontic forces
pulp tissue
title Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire
title_full Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire
title_fullStr Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire
title_full_unstemmed Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire
title_short Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire
title_sort evaluation of sensibility threshold of dental pulp to electric pulp test ept in the teeth under fixed orthodontic treatment with 0 014 and 0 012 initial niti archwire
topic maxillary incisors
orthodontic forces
pulp tissue
url https://jcdr.net/articles/PDF/12459/37722_CE[Ra1]_F(SHU)_PF1(AB_SL)_PN(SL).pdf
work_keys_str_mv AT elhamkhoshbin evaluationofsensibilitythresholdofdentalpulptoelectricpulptesteptintheteethunderfixedorthodontictreatmentwith0014and0012initialnitiarchwire
AT sepidehsoheilifar evaluationofsensibilitythresholdofdentalpulptoelectricpulptesteptintheteethunderfixedorthodontictreatmentwith0014and0012initialnitiarchwire
AT zakiyehdonyavi evaluationofsensibilitythresholdofdentalpulptoelectricpulptesteptintheteethunderfixedorthodontictreatmentwith0014and0012initialnitiarchwire
AT nazaninshahsavand evaluationofsensibilitythresholdofdentalpulptoelectricpulptesteptintheteethunderfixedorthodontictreatmentwith0014and0012initialnitiarchwire