Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance
Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was t...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-05-01
|
Series: | Dentistry Journal |
Subjects: | |
Online Access: | https://www.mdpi.com/2304-6767/10/5/75 |
_version_ | 1797500434123849728 |
---|---|
author | Adityakrisna Yoshi Putra Wigianto Yuichi Ishida Takashi Matsuda Takaharu Goto Megumi Watanabe Tetsuo Ichikawa |
author_facet | Adityakrisna Yoshi Putra Wigianto Yuichi Ishida Takashi Matsuda Takaharu Goto Megumi Watanabe Tetsuo Ichikawa |
author_sort | Adityakrisna Yoshi Putra Wigianto |
collection | DOAJ |
description | Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use. |
first_indexed | 2024-03-10T03:03:46Z |
format | Article |
id | doaj.art-578a264c5a944fab999334100ce7b7bb |
institution | Directory Open Access Journal |
issn | 2304-6767 |
language | English |
last_indexed | 2024-03-10T03:03:46Z |
publishDate | 2022-05-01 |
publisher | MDPI AG |
record_format | Article |
series | Dentistry Journal |
spelling | doaj.art-578a264c5a944fab999334100ce7b7bb2023-11-23T10:37:53ZengMDPI AGDentistry Journal2304-67672022-05-011057510.3390/dj10050075Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic PerformanceAdityakrisna Yoshi Putra Wigianto0Yuichi Ishida1Takashi Matsuda2Takaharu Goto3Megumi Watanabe4Tetsuo Ichikawa5Department of Prosthodontics & Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto, Tokushima 770-8504, JapanDepartment of Prosthodontics & Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto, Tokushima 770-8504, JapanDepartment of Prosthodontics & Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto, Tokushima 770-8504, JapanDepartment of Prosthodontics & Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto, Tokushima 770-8504, JapanDepartment of Prosthodontics & Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto, Tokushima 770-8504, JapanDepartment of Prosthodontics & Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto, Tokushima 770-8504, JapanRecently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.https://www.mdpi.com/2304-6767/10/5/75dental magnetoverdenturemagnetic retentiondenture retentiondenture attachment |
spellingShingle | Adityakrisna Yoshi Putra Wigianto Yuichi Ishida Takashi Matsuda Takaharu Goto Megumi Watanabe Tetsuo Ichikawa Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance Dentistry Journal dental magnet overdenture magnetic retention denture retention denture attachment |
title | Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance |
title_full | Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance |
title_fullStr | Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance |
title_full_unstemmed | Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance |
title_short | Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance |
title_sort | novel magnetic attachment system manufactured using high frequency heat treatment and stamp technique introduction and basic performance |
topic | dental magnet overdenture magnetic retention denture retention denture attachment |
url | https://www.mdpi.com/2304-6767/10/5/75 |
work_keys_str_mv | AT adityakrisnayoshiputrawigianto novelmagneticattachmentsystemmanufacturedusinghighfrequencyheattreatmentandstamptechniqueintroductionandbasicperformance AT yuichiishida novelmagneticattachmentsystemmanufacturedusinghighfrequencyheattreatmentandstamptechniqueintroductionandbasicperformance AT takashimatsuda novelmagneticattachmentsystemmanufacturedusinghighfrequencyheattreatmentandstamptechniqueintroductionandbasicperformance AT takaharugoto novelmagneticattachmentsystemmanufacturedusinghighfrequencyheattreatmentandstamptechniqueintroductionandbasicperformance AT megumiwatanabe novelmagneticattachmentsystemmanufacturedusinghighfrequencyheattreatmentandstamptechniqueintroductionandbasicperformance AT tetsuoichikawa novelmagneticattachmentsystemmanufacturedusinghighfrequencyheattreatmentandstamptechniqueintroductionandbasicperformance |