Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]

Objective: To verify the presence of anti-rotavirus serotype G9P[5] SIgA and the virus neutralization capacity of milk samples from Brazilian women. Methods: SIgA antibody levels reactive to rotavirus G9 were determined in 30 maternal milk samples by enzyme-linked immunosorbent assay (ELISA) using p...

Full description

Bibliographic Details
Main Authors: Simone M.R. Santos, Thalita L. Ferreira, Virgínia S. Quintal, Solange B. Carbonare, Milene Tino-De-Franco
Format: Article
Language:English
Published: Elsevier 2013-09-01
Series:Jornal de Pediatria
Online Access:http://www.sciencedirect.com/science/article/pii/S0021755713001162
_version_ 1798002768733011968
author Simone M.R. Santos
Thalita L. Ferreira
Virgínia S. Quintal
Solange B. Carbonare
Milene Tino-De-Franco
author_facet Simone M.R. Santos
Thalita L. Ferreira
Virgínia S. Quintal
Solange B. Carbonare
Milene Tino-De-Franco
author_sort Simone M.R. Santos
collection DOAJ
description Objective: To verify the presence of anti-rotavirus serotype G9P[5] SIgA and the virus neutralization capacity of milk samples from Brazilian women. Methods: SIgA antibody levels reactive to rotavirus G9 were determined in 30 maternal milk samples by enzyme-linked immunosorbent assay (ELISA) using purified virus suspensions. The samples’ capacity to neutralize rotavirus G9P[5] was analyzed using the MA-104 cells neutralization assay. Results: Great individual variations were observed regarding the SIgA levels and neutralization titers, but all samples showed some G9P[5] neutralizing ability. A highly significant positive correlation was observed between antibody levels and neutralization titers. Conclusions: The high correlation between anti-rotavirus antibody levels and neutralizing capacity of the milk samples suggests a possible protective role of these antibodies against infection. These results also support the encouragement of the breast-feeding practice. Resumo: Objetivo: Verificar a presença de SIgA anti-rotavírus sorotipo G9P[5] e a capacidade de neutralização do vírus de amostras de leite de mulheres brasileiras. Métodos: Foram determinados os níveis de anticorpos IgAS reativos contra rotavírus G9 em 30 amostras de leite materno por ELISA usando suspensões purificadas do vírus. A capacidade das amostras de neutralizarem o rotavírus G9P[5] foi analisada em ensaio de neutralização utilizando células MA-104. Resultados: Foram observadas grandes variações individuais referentes aos níveis de IgAS e títulos de neutralização, mas todas as amostras mostraram certa capacidade de neutralizar o G9P[5]. Verificamos uma correlação positiva altamente significativa entre os níveis de anticorpos e os títulos de neutralização. Conclusões: A alta correlação entre níveis de anticorpos anti-rotavírus e a capacidade neutralizante das amostras de leite sugere um possível papel protetor desses anticorpos contra a infecção. Esses resultados também apoiam o incentivo à prática do aleitamento materno. Keywords: Human milk, Rotavirus, Secretory IgA, Rotavirus neutralization, Palavras-chave: Leite humano, Rotavírus, IgA secretora, Neutralização do rotavírus
first_indexed 2024-04-11T11:58:26Z
format Article
id doaj.art-580754f246c741bcb8babdad350a782a
institution Directory Open Access Journal
issn 0021-7557
language English
last_indexed 2024-04-11T11:58:26Z
publishDate 2013-09-01
publisher Elsevier
record_format Article
series Jornal de Pediatria
spelling doaj.art-580754f246c741bcb8babdad350a782a2022-12-22T04:25:02ZengElsevierJornal de Pediatria0021-75572013-09-01895510513Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]Simone M.R. Santos0Thalita L. Ferreira1Virgínia S. Quintal2Solange B. Carbonare3Milene Tino-De-Franco4MD. Laboratório de Imunogenética, Instituto Butantan, São Paulo, SP, BrazilMD. Laboratório de Imunogenética, Instituto Butantan, São Paulo, SP, BrazilPhD. Banco de Leite Humano, Hospital Universitário da Universidade de São Paulo, São Paulo, SP, BrazilPhD. Laboratório de Imunogenética, Instituto Butantan, São Paulo, SP, BrazilPhD. Laboratório de Imunogenética, Instituto Butantan, São Paulo, SP, Brazil; Corresponding author.Objective: To verify the presence of anti-rotavirus serotype G9P[5] SIgA and the virus neutralization capacity of milk samples from Brazilian women. Methods: SIgA antibody levels reactive to rotavirus G9 were determined in 30 maternal milk samples by enzyme-linked immunosorbent assay (ELISA) using purified virus suspensions. The samples’ capacity to neutralize rotavirus G9P[5] was analyzed using the MA-104 cells neutralization assay. Results: Great individual variations were observed regarding the SIgA levels and neutralization titers, but all samples showed some G9P[5] neutralizing ability. A highly significant positive correlation was observed between antibody levels and neutralization titers. Conclusions: The high correlation between anti-rotavirus antibody levels and neutralizing capacity of the milk samples suggests a possible protective role of these antibodies against infection. These results also support the encouragement of the breast-feeding practice. Resumo: Objetivo: Verificar a presença de SIgA anti-rotavírus sorotipo G9P[5] e a capacidade de neutralização do vírus de amostras de leite de mulheres brasileiras. Métodos: Foram determinados os níveis de anticorpos IgAS reativos contra rotavírus G9 em 30 amostras de leite materno por ELISA usando suspensões purificadas do vírus. A capacidade das amostras de neutralizarem o rotavírus G9P[5] foi analisada em ensaio de neutralização utilizando células MA-104. Resultados: Foram observadas grandes variações individuais referentes aos níveis de IgAS e títulos de neutralização, mas todas as amostras mostraram certa capacidade de neutralizar o G9P[5]. Verificamos uma correlação positiva altamente significativa entre os níveis de anticorpos e os títulos de neutralização. Conclusões: A alta correlação entre níveis de anticorpos anti-rotavírus e a capacidade neutralizante das amostras de leite sugere um possível papel protetor desses anticorpos contra a infecção. Esses resultados também apoiam o incentivo à prática do aleitamento materno. Keywords: Human milk, Rotavirus, Secretory IgA, Rotavirus neutralization, Palavras-chave: Leite humano, Rotavírus, IgA secretora, Neutralização do rotavírushttp://www.sciencedirect.com/science/article/pii/S0021755713001162
spellingShingle Simone M.R. Santos
Thalita L. Ferreira
Virgínia S. Quintal
Solange B. Carbonare
Milene Tino-De-Franco
Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]
Jornal de Pediatria
title Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]
title_full Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]
title_fullStr Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]
title_full_unstemmed Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]
title_short Milk from Brazilian women presents secretory IgA antibodies and neutralizes rotavirus G9P[5]
title_sort milk from brazilian women presents secretory iga antibodies and neutralizes rotavirus g9p 5
url http://www.sciencedirect.com/science/article/pii/S0021755713001162
work_keys_str_mv AT simonemrsantos milkfrombrazilianwomenpresentssecretoryigaantibodiesandneutralizesrotavirusg9p5
AT thalitalferreira milkfrombrazilianwomenpresentssecretoryigaantibodiesandneutralizesrotavirusg9p5
AT virginiasquintal milkfrombrazilianwomenpresentssecretoryigaantibodiesandneutralizesrotavirusg9p5
AT solangebcarbonare milkfrombrazilianwomenpresentssecretoryigaantibodiesandneutralizesrotavirusg9p5
AT milenetinodefranco milkfrombrazilianwomenpresentssecretoryigaantibodiesandneutralizesrotavirusg9p5