Aortic graft infection with enteric organism after embolization of late type II endoleak

An 82-year-old man with a history of endovascular repair for ruptured abdominal aortic aneurysm 6 years ago presented with a type II endoleak and enlarging sac. He had successful transabdominal direct sac puncture embolization but developed fever 2 days postoperatively. Contrast-enhanced computed to...

Full description

Bibliographic Details
Main Authors: Ben Li, BHSc, Kong Teng Tan, MD, Mary Elizabeth MacDonald, MD, PhD, John Byrne, MB BCh, MD
Format: Article
Language:English
Published: Elsevier 2019-03-01
Series:Journal of Vascular Surgery Cases and Innovative Techniques
Online Access:http://www.sciencedirect.com/science/article/pii/S2468428718301370
_version_ 1828428670662868992
author Ben Li, BHSc
Kong Teng Tan, MD
Mary Elizabeth MacDonald, MD, PhD
John Byrne, MB BCh, MD
author_facet Ben Li, BHSc
Kong Teng Tan, MD
Mary Elizabeth MacDonald, MD, PhD
John Byrne, MB BCh, MD
author_sort Ben Li, BHSc
collection DOAJ
description An 82-year-old man with a history of endovascular repair for ruptured abdominal aortic aneurysm 6 years ago presented with a type II endoleak and enlarging sac. He had successful transabdominal direct sac puncture embolization but developed fever 2 days postoperatively. Contrast-enhanced computed tomography showed a rim-enhancing collection, and sac aspiration was positive for enteric organisms, confirming endograft infection. The patient underwent graft explantation and neoaortic reconstruction using superficial femoral veins. Three months postoperatively, computed tomography showed complete resolution of fluid collection and no signs of graft infection. This report illustrates direct puncture embolization complicated by endograft infection from enteric bacteria. Keywords: Abdominal aortic aneurysm, Endovascular aneurysm repair, Graft infection, Endoleak embolization, Aortic reconstruction
first_indexed 2024-12-10T17:21:23Z
format Article
id doaj.art-5883c2979a7b4e0a972a76f0833bdc78
institution Directory Open Access Journal
issn 2468-4287
language English
last_indexed 2024-12-10T17:21:23Z
publishDate 2019-03-01
publisher Elsevier
record_format Article
series Journal of Vascular Surgery Cases and Innovative Techniques
spelling doaj.art-5883c2979a7b4e0a972a76f0833bdc782022-12-22T01:39:58ZengElsevierJournal of Vascular Surgery Cases and Innovative Techniques2468-42872019-03-01516164Aortic graft infection with enteric organism after embolization of late type II endoleakBen Li, BHSc0Kong Teng Tan, MD1Mary Elizabeth MacDonald, MD, PhD2John Byrne, MB BCh, MD3Division of Vascular Surgery, Department of Surgery, Toronto General Hospital, University Health Network, University of Toronto, Toronto, Ontario, CanadaDivision of Vascular and Interventional Radiology, Department of Medical Imaging, Toronto General Hospital, University Health Network, University of Toronto, Toronto, Ontario, CanadaDivision of Vascular Surgery, Department of Surgery, Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, CanadaDivision of Vascular Surgery, Department of Surgery, Toronto General Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada; Correspondence: John Byrne, MB BCh, MD, Assistant Professor, Division of Vascular Surgery, 6EN-214, Toronto General Hospital, 200 Elizabeth St, Toronto, Ontario, Canada M5G 2C4An 82-year-old man with a history of endovascular repair for ruptured abdominal aortic aneurysm 6 years ago presented with a type II endoleak and enlarging sac. He had successful transabdominal direct sac puncture embolization but developed fever 2 days postoperatively. Contrast-enhanced computed tomography showed a rim-enhancing collection, and sac aspiration was positive for enteric organisms, confirming endograft infection. The patient underwent graft explantation and neoaortic reconstruction using superficial femoral veins. Three months postoperatively, computed tomography showed complete resolution of fluid collection and no signs of graft infection. This report illustrates direct puncture embolization complicated by endograft infection from enteric bacteria. Keywords: Abdominal aortic aneurysm, Endovascular aneurysm repair, Graft infection, Endoleak embolization, Aortic reconstructionhttp://www.sciencedirect.com/science/article/pii/S2468428718301370
spellingShingle Ben Li, BHSc
Kong Teng Tan, MD
Mary Elizabeth MacDonald, MD, PhD
John Byrne, MB BCh, MD
Aortic graft infection with enteric organism after embolization of late type II endoleak
Journal of Vascular Surgery Cases and Innovative Techniques
title Aortic graft infection with enteric organism after embolization of late type II endoleak
title_full Aortic graft infection with enteric organism after embolization of late type II endoleak
title_fullStr Aortic graft infection with enteric organism after embolization of late type II endoleak
title_full_unstemmed Aortic graft infection with enteric organism after embolization of late type II endoleak
title_short Aortic graft infection with enteric organism after embolization of late type II endoleak
title_sort aortic graft infection with enteric organism after embolization of late type ii endoleak
url http://www.sciencedirect.com/science/article/pii/S2468428718301370
work_keys_str_mv AT benlibhsc aorticgraftinfectionwithentericorganismafterembolizationoflatetypeiiendoleak
AT kongtengtanmd aorticgraftinfectionwithentericorganismafterembolizationoflatetypeiiendoleak
AT maryelizabethmacdonaldmdphd aorticgraftinfectionwithentericorganismafterembolizationoflatetypeiiendoleak
AT johnbyrnembbchmd aorticgraftinfectionwithentericorganismafterembolizationoflatetypeiiendoleak