A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation
Transvenous pacemaker or implantable cardioverter defibrillator (ICD) implantation procedures are usually performed under local anesthetic, and prilocaine is the most common agent to be used. The data regarding methemoglobinemia after cardiac device implantation are scarce. Thus, presently described...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
KARE Publishing
2017-09-01
|
Series: | Türk Kardiyoloji Derneği Arşivi |
Subjects: | |
Online Access: | https://jag.journalagent.com/z4/download_fulltext.asp?pdir=tkd&un=TKDA-34801 |
_version_ | 1797917865088647168 |
---|---|
author | Uğur Canpolat Nihan Bahadır Levent Şahiner Kudret Aytemir |
author_facet | Uğur Canpolat Nihan Bahadır Levent Şahiner Kudret Aytemir |
author_sort | Uğur Canpolat |
collection | DOAJ |
description | Transvenous pacemaker or implantable cardioverter defibrillator (ICD) implantation procedures are usually performed under local anesthetic, and prilocaine is the most common agent to be used. The data regarding methemoglobinemia after cardiac device implantation are scarce. Thus, presently described is the case of a 47-year-old female patient with arrhythmogenic right ventricular cardiomyopathy/dysplasia who underwent ICD implantation for secondary prophylaxis and developed cyanosis as a result of prilocaine-associated methemoglobinemia. Prilocaine was administered during the procedure. To our knowledge, this is the second case in the literature presenting methemoglobinemia due to local anesthetic after transvenous cardiac device implantation. |
first_indexed | 2024-04-10T13:20:11Z |
format | Article |
id | doaj.art-58b8d733b89c42a7ae6deb0161054bc7 |
institution | Directory Open Access Journal |
issn | 1016-5169 |
language | English |
last_indexed | 2024-04-10T13:20:11Z |
publishDate | 2017-09-01 |
publisher | KARE Publishing |
record_format | Article |
series | Türk Kardiyoloji Derneği Arşivi |
spelling | doaj.art-58b8d733b89c42a7ae6deb0161054bc72023-02-15T16:12:05ZengKARE PublishingTürk Kardiyoloji Derneği Arşivi1016-51692017-09-0145656056210.5543/tkda.2017.34801TKDA-34801A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantationUğur Canpolat0Nihan Bahadır1Levent Şahiner2Kudret Aytemir3Department of Cardiology, Hacettepe University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Hacettepe University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Hacettepe University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Hacettepe University Faculty of Medicine, Ankara, TurkeyTransvenous pacemaker or implantable cardioverter defibrillator (ICD) implantation procedures are usually performed under local anesthetic, and prilocaine is the most common agent to be used. The data regarding methemoglobinemia after cardiac device implantation are scarce. Thus, presently described is the case of a 47-year-old female patient with arrhythmogenic right ventricular cardiomyopathy/dysplasia who underwent ICD implantation for secondary prophylaxis and developed cyanosis as a result of prilocaine-associated methemoglobinemia. Prilocaine was administered during the procedure. To our knowledge, this is the second case in the literature presenting methemoglobinemia due to local anesthetic after transvenous cardiac device implantation.https://jag.journalagent.com/z4/download_fulltext.asp?pdir=tkd&un=TKDA-34801cardiovascular electronic devicecomplicationmethemoglobinemia. |
spellingShingle | Uğur Canpolat Nihan Bahadır Levent Şahiner Kudret Aytemir A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation Türk Kardiyoloji Derneği Arşivi cardiovascular electronic device complication methemoglobinemia. |
title | A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation |
title_full | A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation |
title_fullStr | A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation |
title_full_unstemmed | A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation |
title_short | A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation |
title_sort | rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation |
topic | cardiovascular electronic device complication methemoglobinemia. |
url | https://jag.journalagent.com/z4/download_fulltext.asp?pdir=tkd&un=TKDA-34801 |
work_keys_str_mv | AT ugurcanpolat ararecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT nihanbahadır ararecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT leventsahiner ararecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT kudretaytemir ararecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT ugurcanpolat rarecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT nihanbahadır rarecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT leventsahiner rarecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation AT kudretaytemir rarecauseofcyanosisandhypoxiathatshouldnotbeforgottenafterimplantablecardioverterdefibrillatorimplantation |