BackgroundDetection of antibodies to extractable nuclear antigens (ENAs) is needed for the diagnosis in systemic autoimmune diseases. In this study, we compared three reagents using line immunoblot assay (LIA) or multiplex bead immunoassay for detecting the anti-ENAs. MethodsA total of 89 sera were...

Full description

Bibliographic Details
Main Authors: Namhee Kim, In-Suk Kim, Chulhun L Chang, Hyung-Hoi Kim, Eun Yup Lee
Format: Article
Language:English
Published: Kosin University College of Medicine 2018-01-01
Series:Kosin Medical Journal
Subjects:
Online Access:http://www.kosinmedj.org/upload/pdf/ksmc033-03-04.pdf
_version_ 1811192736022265856
author Namhee Kim
In-Suk Kim
Chulhun L Chang
Hyung-Hoi Kim
Eun Yup Lee
author_facet Namhee Kim
In-Suk Kim
Chulhun L Chang
Hyung-Hoi Kim
Eun Yup Lee
author_sort Namhee Kim
collection DOAJ
description BackgroundDetection of antibodies to extractable nuclear antigens (ENAs) is needed for the diagnosis in systemic autoimmune diseases. In this study, we compared three reagents using line immunoblot assay (LIA) or multiplex bead immunoassay for detecting the anti-ENAs. MethodsA total of 89 sera were tested by 3 different assays: EUROASSAY Anti-ENA Profile (Euroimmune, Germany), Polycheck Autoimmune Test (Biocheck GmbH, Germany), and FIDIS™ Connective Profile (Biomedical Diagnostics, France). The following individual ENAs were investigated: Sm, SS-A (Ro), SS-B (La), Scl-70, Jo-1 and RNP. We reviewed medical records to investigate the discrepant results among three methods. ResultsOverall percent agreements were 96.1% between EUROASSAY Anti-ENA Profile and FIDIS™ Connective profile; 90.4% between EUROASSAY Anti-ENA Profile and Polycheck Autoimmune Test using the manufacturers’ cutoff; 96.4% between EUROASSAY Anti-ENA Profile and Polycheck Autoimmune Test using a upward cutoff; 90.4% between FIDIS™ Connective profile and Polycheck Autoimmune Test the manufacturers’ cutoff; and 96.4% between FIDIS™ Connective profile and Polycheck Autoimmune Test a upward cutoff. ConclusionsThe three assays showed excellent agreement with each other. With appropriate cutoff, the all three assays for six of the anti-ENA tests investigated in this study can be used in clinical laboratories for detecting the anti-ENAs.
first_indexed 2024-04-11T23:56:18Z
format Article
id doaj.art-58f3f9ca27db4938a7aaee2c25c907d7
institution Directory Open Access Journal
issn 2005-9531
2586-7024
language English
last_indexed 2024-04-11T23:56:18Z
publishDate 2018-01-01
publisher Kosin University College of Medicine
record_format Article
series Kosin Medical Journal
spelling doaj.art-58f3f9ca27db4938a7aaee2c25c907d72022-12-22T03:56:21ZengKosin University College of MedicineKosin Medical Journal2005-95312586-70242018-01-0133330731710.7180/kmj.2018.33.3.307209Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective ProfileNamhee Kim0In-Suk Kim1Chulhun L Chang2Hyung-Hoi Kim3Eun Yup Lee4Department of Laboratory Medicine, School of Medicine, Pusan National University, Busan, KoreaDepartment of Laboratory Medicine, School of Medicine, Pusan National University, Busan, KoreaDepartment of Laboratory Medicine, School of Medicine, Pusan National University, Busan, KoreaDepartment of Laboratory Medicine, School of Medicine, Pusan National University, Busan, KoreaDepartment of Laboratory Medicine, School of Medicine, Pusan National University, Busan, KoreaBackgroundDetection of antibodies to extractable nuclear antigens (ENAs) is needed for the diagnosis in systemic autoimmune diseases. In this study, we compared three reagents using line immunoblot assay (LIA) or multiplex bead immunoassay for detecting the anti-ENAs. MethodsA total of 89 sera were tested by 3 different assays: EUROASSAY Anti-ENA Profile (Euroimmune, Germany), Polycheck Autoimmune Test (Biocheck GmbH, Germany), and FIDIS™ Connective Profile (Biomedical Diagnostics, France). The following individual ENAs were investigated: Sm, SS-A (Ro), SS-B (La), Scl-70, Jo-1 and RNP. We reviewed medical records to investigate the discrepant results among three methods. ResultsOverall percent agreements were 96.1% between EUROASSAY Anti-ENA Profile and FIDIS™ Connective profile; 90.4% between EUROASSAY Anti-ENA Profile and Polycheck Autoimmune Test using the manufacturers’ cutoff; 96.4% between EUROASSAY Anti-ENA Profile and Polycheck Autoimmune Test using a upward cutoff; 90.4% between FIDIS™ Connective profile and Polycheck Autoimmune Test the manufacturers’ cutoff; and 96.4% between FIDIS™ Connective profile and Polycheck Autoimmune Test a upward cutoff. ConclusionsThe three assays showed excellent agreement with each other. With appropriate cutoff, the all three assays for six of the anti-ENA tests investigated in this study can be used in clinical laboratories for detecting the anti-ENAs.http://www.kosinmedj.org/upload/pdf/ksmc033-03-04.pdfanti-extractable nuclear antigen antibodiesantinuclear antibodiesautoimmunity
spellingShingle Namhee Kim
In-Suk Kim
Chulhun L Chang
Hyung-Hoi Kim
Eun Yup Lee
Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective Profile
Kosin Medical Journal
anti-extractable nuclear antigen antibodies
antinuclear antibodies
autoimmunity
title Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective Profile
title_full Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective Profile
title_fullStr Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective Profile
title_full_unstemmed Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective Profile
title_short Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FID Connective Profile
title_sort agreement of three commercial anti extractable nuclear antigen tests euroassay anti ena profile polycheck autoimmune test and fid connective profile
topic anti-extractable nuclear antigen antibodies
antinuclear antibodies
autoimmunity
url http://www.kosinmedj.org/upload/pdf/ksmc033-03-04.pdf
work_keys_str_mv AT namheekim agreementofthreecommercialantiextractablenuclearantigentestseuroassayantienaprofilepolycheckautoimmunetestandfidconnectiveprofile
AT insukkim agreementofthreecommercialantiextractablenuclearantigentestseuroassayantienaprofilepolycheckautoimmunetestandfidconnectiveprofile
AT chulhunlchang agreementofthreecommercialantiextractablenuclearantigentestseuroassayantienaprofilepolycheckautoimmunetestandfidconnectiveprofile
AT hyunghoikim agreementofthreecommercialantiextractablenuclearantigentestseuroassayantienaprofilepolycheckautoimmunetestandfidconnectiveprofile
AT eunyuplee agreementofthreecommercialantiextractablenuclearantigentestseuroassayantienaprofilepolycheckautoimmunetestandfidconnectiveprofile