Stator fault diagnosis in induction motors using the leakage axial flux
This work shows the importance of a predictive maintenance program, the diagnosis techniques and the experimental results obtained from the measurement of the leakage axial flux to diagnosis in order to detect stator winding faults in induction motors. The types of coils designed to capture the axi...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidad de Antioquia
2004-11-01
|
Series: | Revista Facultad de Ingeniería Universidad de Antioquia |
Subjects: | |
Online Access: | https://revistas.udea.edu.co/index.php/ingenieria/article/view/344371 |
Summary: | This work shows the importance of a predictive maintenance program, the diagnosis techniques and the experimental results obtained from the measurement of the leakage axial flux to diagnosis in order to detect stator winding faults in induction motors. The types of coils designed to capture the axial flux signal and economic considerations to implement this diagnosis technique are also described.
|
---|---|