Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias

(1) Background: Near-infrared spectroscopy (NIRS) is an innovative and non-invasive technology used to investigate muscular oxygenation. The aim of this study is to assess the within- and between-session reliability of the NIRS Portamon (Artinis, Elst, Netherlands) device following three sets of ind...

Full description

Bibliographic Details
Main Authors: Julien Desanlis, Dan Gordon, Camille Calveyrac, François Cottin, Marie Gernigon
Format: Article
Language:English
Published: MDPI AG 2022-07-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/22/14/5165
_version_ 1827626877711286272
author Julien Desanlis
Dan Gordon
Camille Calveyrac
François Cottin
Marie Gernigon
author_facet Julien Desanlis
Dan Gordon
Camille Calveyrac
François Cottin
Marie Gernigon
author_sort Julien Desanlis
collection DOAJ
description (1) Background: Near-infrared spectroscopy (NIRS) is an innovative and non-invasive technology used to investigate muscular oxygenation. The aim of this study is to assess the within- and between-session reliability of the NIRS Portamon (Artinis, Elst, Netherlands) device following three sets of induced muscle ischemia. (2) Methods: Depending on the experimental group (G1, G2 or G3), a cuff was inflated three times on the left upper arm to 50 mmHg (G1), systolic blood pressure (SBP) + 50 mmHg (G2) or 250 mmHg (G3). Maximum, minimum and reoxygenation rate values were assessed after each occlusion phase, using a Portamon device placed on the left brachioradialis. Reliability was assessed with intraclass correlation coefficient (ICC) value and ICC 95% confidence interval (CI-95%), coefficient of variation (CV) and standard error of measurement (SEM) (3) Results: Our results showed a good to excellent reliability for maximums and minimums within-session. However, the reoxygenation rate within sessions as well as measurements between sessions cannot predominantly show good reliability. (4) Conclusions: Multiple measurements of maximums and minimums within a single session appeared to be reliable which shows that only one measurement is necessary to assess these parameters. However, it is necessary to be cautious with a comparison of maximum, minimum and reoxygenation rate values between sessions.
first_indexed 2024-03-09T13:03:42Z
format Article
id doaj.art-5914e0cd32614430aef170803d67e9c2
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-09T13:03:42Z
publishDate 2022-07-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-5914e0cd32614430aef170803d67e9c22023-11-30T21:50:51ZengMDPI AGSensors1424-82202022-07-012214516510.3390/s22145165Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle IschemiasJulien Desanlis0Dan Gordon1Camille Calveyrac2François Cottin3Marie Gernigon4CIAMS, Université Paris-Saclay, CEDEX, 91405 Orsay, FranceAnglia Ruskin University, Cambridge CB1 1PT, UKCIAMS, Université Paris-Saclay, CEDEX, 91405 Orsay, FranceCIAMS, Université Paris-Saclay, CEDEX, 91405 Orsay, FranceCIAMS, Université Paris-Saclay, CEDEX, 91405 Orsay, France(1) Background: Near-infrared spectroscopy (NIRS) is an innovative and non-invasive technology used to investigate muscular oxygenation. The aim of this study is to assess the within- and between-session reliability of the NIRS Portamon (Artinis, Elst, Netherlands) device following three sets of induced muscle ischemia. (2) Methods: Depending on the experimental group (G1, G2 or G3), a cuff was inflated three times on the left upper arm to 50 mmHg (G1), systolic blood pressure (SBP) + 50 mmHg (G2) or 250 mmHg (G3). Maximum, minimum and reoxygenation rate values were assessed after each occlusion phase, using a Portamon device placed on the left brachioradialis. Reliability was assessed with intraclass correlation coefficient (ICC) value and ICC 95% confidence interval (CI-95%), coefficient of variation (CV) and standard error of measurement (SEM) (3) Results: Our results showed a good to excellent reliability for maximums and minimums within-session. However, the reoxygenation rate within sessions as well as measurements between sessions cannot predominantly show good reliability. (4) Conclusions: Multiple measurements of maximums and minimums within a single session appeared to be reliable which shows that only one measurement is necessary to assess these parameters. However, it is necessary to be cautious with a comparison of maximum, minimum and reoxygenation rate values between sessions.https://www.mdpi.com/1424-8220/22/14/5165test–retestarterial occlusionblood flow restrictionischemic preconditioninghyperemia
spellingShingle Julien Desanlis
Dan Gordon
Camille Calveyrac
François Cottin
Marie Gernigon
Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
Sensors
test–retest
arterial occlusion
blood flow restriction
ischemic preconditioning
hyperemia
title Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
title_full Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
title_fullStr Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
title_full_unstemmed Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
title_short Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
title_sort intra and inter day reliability of the nirs portamon device after three induced muscle ischemias
topic test–retest
arterial occlusion
blood flow restriction
ischemic preconditioning
hyperemia
url https://www.mdpi.com/1424-8220/22/14/5165
work_keys_str_mv AT juliendesanlis intraandinterdayreliabilityofthenirsportamondeviceafterthreeinducedmuscleischemias
AT dangordon intraandinterdayreliabilityofthenirsportamondeviceafterthreeinducedmuscleischemias
AT camillecalveyrac intraandinterdayreliabilityofthenirsportamondeviceafterthreeinducedmuscleischemias
AT francoiscottin intraandinterdayreliabilityofthenirsportamondeviceafterthreeinducedmuscleischemias
AT mariegernigon intraandinterdayreliabilityofthenirsportamondeviceafterthreeinducedmuscleischemias