Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment

Significant fire and explosion accident on spherical tanks for Liquefied Petroleum Gas (LPG) storage was induced by the strong ground motion of the 2011 Great East Japan Earthquake. Steel pipe braces were broken due to the strong seismic inertia force, and then buckling of support legs occurred. To...

Full description

Bibliographic Details
Main Authors: Takashi OHNO, Nobuyuki KOBAYASHI, Osamu FURUYA, Kenji OYAMADA
Format: Article
Language:Japanese
Published: The Japan Society of Mechanical Engineers 2015-12-01
Series:Nihon Kikai Gakkai ronbunshu
Subjects:
Online Access:https://www.jstage.jst.go.jp/article/transjsme/82/833/82_15-00486/_pdf/-char/en
_version_ 1798015248879321088
author Takashi OHNO
Nobuyuki KOBAYASHI
Osamu FURUYA
Kenji OYAMADA
author_facet Takashi OHNO
Nobuyuki KOBAYASHI
Osamu FURUYA
Kenji OYAMADA
author_sort Takashi OHNO
collection DOAJ
description Significant fire and explosion accident on spherical tanks for Liquefied Petroleum Gas (LPG) storage was induced by the strong ground motion of the 2011 Great East Japan Earthquake. Steel pipe braces were broken due to the strong seismic inertia force, and then buckling of support legs occurred. To prevent recurrence, reinforcing the intersection of braces was needed. Currently, in the Japanese seismic resistance design standard for high pressure equipment including spherical tanks for storage, when subjected to a large earthquake, it is allowed to occur a certain degree of plastic deformation, witch way not lead to release high pressure gases. When receiving a high-level seismic motion, seismic response of high pressure equipment could be non-linear due to plastic deformation and the mechanical damping could be increased as well. On the other hand, a vibration test for spherical tank has not conducted in the past. Deformation behavior of the spherical tank and pipe braces was not clear against real ground motion. In addition, there are not many precedent studies done on the effectiveness of the reinforcement of pipe braced supporting frame against high-level ground motion. In this study, we conducted vibration tests using small models of spherical tank and examined non-linear response characteristics and failure mode due to plastic deformation. From the test results, it was concluded the effectiveness of reinforcement and the response characteristic of the pipe braced supporting frame of a spherical tank as follows; (1) The natural frequency indicates substantially the same value with or without reinforcement, because a large difference in the response characteristics of the whole structure was not observed. (2) In a case of brace intersection was reinforced, the maximum response acceleration increased at collapse. (3) In a case of brace intersection was reinforced there is no reinforcement to brace intersection, structural strength indicated the lowest at the load direction acting tensile force on long brace, cross section of long brace were deformed largely.
first_indexed 2024-04-11T15:30:21Z
format Article
id doaj.art-598b704eeac443e89752417e7bed044a
institution Directory Open Access Journal
issn 2187-9761
language Japanese
last_indexed 2024-04-11T15:30:21Z
publishDate 2015-12-01
publisher The Japan Society of Mechanical Engineers
record_format Article
series Nihon Kikai Gakkai ronbunshu
spelling doaj.art-598b704eeac443e89752417e7bed044a2022-12-22T04:16:09ZjpnThe Japan Society of Mechanical EngineersNihon Kikai Gakkai ronbunshu2187-97612015-12-018283315-0048615-0048610.1299/transjsme.15-00486transjsmeEvaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experimentTakashi OHNO0Nobuyuki KOBAYASHI1Osamu FURUYA2Kenji OYAMADA3Graduate School of Aoyama Gakuin UniversityAoyama Gakuin University, College of Science and EngineeringTokyo City University, Faculty of EngineeringThe High Pressure Gas Safety Institute of JapanSignificant fire and explosion accident on spherical tanks for Liquefied Petroleum Gas (LPG) storage was induced by the strong ground motion of the 2011 Great East Japan Earthquake. Steel pipe braces were broken due to the strong seismic inertia force, and then buckling of support legs occurred. To prevent recurrence, reinforcing the intersection of braces was needed. Currently, in the Japanese seismic resistance design standard for high pressure equipment including spherical tanks for storage, when subjected to a large earthquake, it is allowed to occur a certain degree of plastic deformation, witch way not lead to release high pressure gases. When receiving a high-level seismic motion, seismic response of high pressure equipment could be non-linear due to plastic deformation and the mechanical damping could be increased as well. On the other hand, a vibration test for spherical tank has not conducted in the past. Deformation behavior of the spherical tank and pipe braces was not clear against real ground motion. In addition, there are not many precedent studies done on the effectiveness of the reinforcement of pipe braced supporting frame against high-level ground motion. In this study, we conducted vibration tests using small models of spherical tank and examined non-linear response characteristics and failure mode due to plastic deformation. From the test results, it was concluded the effectiveness of reinforcement and the response characteristic of the pipe braced supporting frame of a spherical tank as follows; (1) The natural frequency indicates substantially the same value with or without reinforcement, because a large difference in the response characteristics of the whole structure was not observed. (2) In a case of brace intersection was reinforced, the maximum response acceleration increased at collapse. (3) In a case of brace intersection was reinforced there is no reinforcement to brace intersection, structural strength indicated the lowest at the load direction acting tensile force on long brace, cross section of long brace were deformed largely.https://www.jstage.jst.go.jp/article/transjsme/82/833/82_15-00486/_pdf/-char/enspherical tankseismic performancepipe braceshaking testfem analysis
spellingShingle Takashi OHNO
Nobuyuki KOBAYASHI
Osamu FURUYA
Kenji OYAMADA
Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
Nihon Kikai Gakkai ronbunshu
spherical tank
seismic performance
pipe brace
shaking test
fem analysis
title Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
title_full Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
title_fullStr Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
title_full_unstemmed Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
title_short Evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
title_sort evaluation of seismic resistance capacity on pipe braced supporting frame of spherical tank by shaking experiment
topic spherical tank
seismic performance
pipe brace
shaking test
fem analysis
url https://www.jstage.jst.go.jp/article/transjsme/82/833/82_15-00486/_pdf/-char/en
work_keys_str_mv AT takashiohno evaluationofseismicresistancecapacityonpipebracedsupportingframeofsphericaltankbyshakingexperiment
AT nobuyukikobayashi evaluationofseismicresistancecapacityonpipebracedsupportingframeofsphericaltankbyshakingexperiment
AT osamufuruya evaluationofseismicresistancecapacityonpipebracedsupportingframeofsphericaltankbyshakingexperiment
AT kenjioyamada evaluationofseismicresistancecapacityonpipebracedsupportingframeofsphericaltankbyshakingexperiment