Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
<p>Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibratio...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Copernicus Publications
2024-01-01
|
Series: | Journal of Sensors and Sensor Systems |
Online Access: | https://jsss.copernicus.org/articles/13/1/2024/jsss-13-1-2024.pdf |
_version_ | 1827373717177499648 |
---|---|
author | Y. Sperling R. B. Bergmann R. B. Bergmann |
author_facet | Y. Sperling R. B. Bergmann R. B. Bergmann |
author_sort | Y. Sperling |
collection | DOAJ |
description | <p>Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibration. Geometric calibration can be performed by inserting a planar mirror into the setup that brings all camera fields of view to overlap on an active pattern display. The mirror is tilted to multiple positions and each time the cameras capture the displayed images, which yields sufficient data to obtain the relative camera positions and the positions of the mirror. In this article, we give a more detailed description of PMD–ADR and its calibration. We also implement a laser-tracker-based reference method to measure the mirror positions and use its result to expose systematic errors in the geometric calibration.</p> |
first_indexed | 2024-03-08T11:21:22Z |
format | Article |
id | doaj.art-5a0f19b9b1374d52a4d059aef218e0a7 |
institution | Directory Open Access Journal |
issn | 2194-8771 2194-878X |
language | English |
last_indexed | 2024-03-08T11:21:22Z |
publishDate | 2024-01-01 |
publisher | Copernicus Publications |
record_format | Article |
series | Journal of Sensors and Sensor Systems |
spelling | doaj.art-5a0f19b9b1374d52a4d059aef218e0a72024-01-26T09:21:13ZengCopernicus PublicationsJournal of Sensors and Sensor Systems2194-87712194-878X2024-01-01131710.5194/jsss-13-1-2024Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registrationY. Sperling0R. B. Bergmann1R. B. Bergmann2BIAS – Bremer Institut für angewandte Strahltechnik, Klagenfurter Str. 5, 28359 Bremen, GermanyBIAS – Bremer Institut für angewandte Strahltechnik, Klagenfurter Str. 5, 28359 Bremen, GermanyFaculty 1: Physics and Electrical Engineering, University of Bremen, Otto Hahn Allee 1, 28359 Bremen, Germany<p>Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibration. Geometric calibration can be performed by inserting a planar mirror into the setup that brings all camera fields of view to overlap on an active pattern display. The mirror is tilted to multiple positions and each time the cameras capture the displayed images, which yields sufficient data to obtain the relative camera positions and the positions of the mirror. In this article, we give a more detailed description of PMD–ADR and its calibration. We also implement a laser-tracker-based reference method to measure the mirror positions and use its result to expose systematic errors in the geometric calibration.</p>https://jsss.copernicus.org/articles/13/1/2024/jsss-13-1-2024.pdf |
spellingShingle | Y. Sperling R. B. Bergmann R. B. Bergmann Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration Journal of Sensors and Sensor Systems |
title | Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration |
title_full | Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration |
title_fullStr | Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration |
title_full_unstemmed | Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration |
title_short | Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration |
title_sort | laser tracker based reference measurement for geometric calibration of phase measuring deflectometry with active display registration |
url | https://jsss.copernicus.org/articles/13/1/2024/jsss-13-1-2024.pdf |
work_keys_str_mv | AT ysperling lasertrackerbasedreferencemeasurementforgeometriccalibrationofphasemeasuringdeflectometrywithactivedisplayregistration AT rbbergmann lasertrackerbasedreferencemeasurementforgeometriccalibrationofphasemeasuringdeflectometrywithactivedisplayregistration AT rbbergmann lasertrackerbasedreferencemeasurementforgeometriccalibrationofphasemeasuringdeflectometrywithactivedisplayregistration |