Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration

<p>Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibratio...

Full description

Bibliographic Details
Main Authors: Y. Sperling, R. B. Bergmann
Format: Article
Language:English
Published: Copernicus Publications 2024-01-01
Series:Journal of Sensors and Sensor Systems
Online Access:https://jsss.copernicus.org/articles/13/1/2024/jsss-13-1-2024.pdf
_version_ 1827373717177499648
author Y. Sperling
R. B. Bergmann
R. B. Bergmann
author_facet Y. Sperling
R. B. Bergmann
R. B. Bergmann
author_sort Y. Sperling
collection DOAJ
description <p>Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibration. Geometric calibration can be performed by inserting a planar mirror into the setup that brings all camera fields of view to overlap on an active pattern display. The mirror is tilted to multiple positions and each time the cameras capture the displayed images, which yields sufficient data to obtain the relative camera positions and the positions of the mirror. In this article, we give a more detailed description of PMD–ADR and its calibration. We also implement a laser-tracker-based reference method to measure the mirror positions and use its result to expose systematic errors in the geometric calibration.</p>
first_indexed 2024-03-08T11:21:22Z
format Article
id doaj.art-5a0f19b9b1374d52a4d059aef218e0a7
institution Directory Open Access Journal
issn 2194-8771
2194-878X
language English
last_indexed 2024-03-08T11:21:22Z
publishDate 2024-01-01
publisher Copernicus Publications
record_format Article
series Journal of Sensors and Sensor Systems
spelling doaj.art-5a0f19b9b1374d52a4d059aef218e0a72024-01-26T09:21:13ZengCopernicus PublicationsJournal of Sensors and Sensor Systems2194-87712194-878X2024-01-01131710.5194/jsss-13-1-2024Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registrationY. Sperling0R. B. Bergmann1R. B. Bergmann2BIAS – Bremer Institut für angewandte Strahltechnik, Klagenfurter Str. 5, 28359 Bremen, GermanyBIAS – Bremer Institut für angewandte Strahltechnik, Klagenfurter Str. 5, 28359 Bremen, GermanyFaculty 1: Physics and Electrical Engineering, University of Bremen, Otto Hahn Allee 1, 28359 Bremen, Germany<p>Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibration. Geometric calibration can be performed by inserting a planar mirror into the setup that brings all camera fields of view to overlap on an active pattern display. The mirror is tilted to multiple positions and each time the cameras capture the displayed images, which yields sufficient data to obtain the relative camera positions and the positions of the mirror. In this article, we give a more detailed description of PMD–ADR and its calibration. We also implement a laser-tracker-based reference method to measure the mirror positions and use its result to expose systematic errors in the geometric calibration.</p>https://jsss.copernicus.org/articles/13/1/2024/jsss-13-1-2024.pdf
spellingShingle Y. Sperling
R. B. Bergmann
R. B. Bergmann
Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
Journal of Sensors and Sensor Systems
title Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
title_full Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
title_fullStr Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
title_full_unstemmed Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
title_short Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration
title_sort laser tracker based reference measurement for geometric calibration of phase measuring deflectometry with active display registration
url https://jsss.copernicus.org/articles/13/1/2024/jsss-13-1-2024.pdf
work_keys_str_mv AT ysperling lasertrackerbasedreferencemeasurementforgeometriccalibrationofphasemeasuringdeflectometrywithactivedisplayregistration
AT rbbergmann lasertrackerbasedreferencemeasurementforgeometriccalibrationofphasemeasuringdeflectometrywithactivedisplayregistration
AT rbbergmann lasertrackerbasedreferencemeasurementforgeometriccalibrationofphasemeasuringdeflectometrywithactivedisplayregistration