Analysis and Estimation of Core Damage Frequency of Flow Blockage and Loss of Coolant Accident: A Case Study of a 10 MW Water-Water Research Reactor-PSA Level 1

Fault trees (FT) and event trees (ET) are widely used in industry to model and evaluate the reliability of safety systems. This work seeks to analyze and estimate the core damage frequency (CDF) due to flow blockage (FB) and loss of coolant accident (LOCA) due to large rupture of primary circuit pip...

Full description

Bibliographic Details
Main Authors: F. Ameyaw, R. Abrefah, S. Yamoah, S. Birikorang
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2021/9423176