Analysis and Estimation of Core Damage Frequency of Flow Blockage and Loss of Coolant Accident: A Case Study of a 10 MW Water-Water Research Reactor-PSA Level 1
Fault trees (FT) and event trees (ET) are widely used in industry to model and evaluate the reliability of safety systems. This work seeks to analyze and estimate the core damage frequency (CDF) due to flow blockage (FB) and loss of coolant accident (LOCA) due to large rupture of primary circuit pip...
Main Authors: | F. Ameyaw, R. Abrefah, S. Yamoah, S. Birikorang |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2021-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2021/9423176 |
Similar Items
-
Pressurized water reactor loss-of-coolant accidents by hypothetical vessel rupture
by: Doan, Phung Lien, et al.
Published: (2014) -
Temperature Transients of Fusion-fission Hybrid Reactors in Loss of Coolant Accidents
by: Tang, Vincent, et al.
Published: (2015) -
Prediction of peak cladding temperature in a three-loop pressurised water reactor with accident- tolerant fuel during loss-of-coolant accident
by: Agung, Alexander
Published: (2018) -
Analysis of forces on core structures during a loss-of-coolant accident
by: Griggs, D. P.
Published: (2011) -
Flow Blockage Accident Analysis of Tehran Research Reactor Fuel Assembly
by: J. Jafari, et al.
Published: (2011-02-01)