Electron streams in air during magnetic-resonance image-guided radiation therapy.

To investigate the undesired irradiations outside of the treatment field by electron streams in air (air-electron-stream) during magnetic-resonance image-guided radiation therapy (MR-IGRT). A custom-made support phantom adjusting angles between the beam central axis (CAX) and the phantom surface (te...

Full description

Bibliographic Details
Main Authors: Hyun Joon An, Jung-In Kim, Jong Min Park
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0216965
_version_ 1818590275340075008
author Hyun Joon An
Jung-In Kim
Jong Min Park
author_facet Hyun Joon An
Jung-In Kim
Jong Min Park
author_sort Hyun Joon An
collection DOAJ
description To investigate the undesired irradiations outside of the treatment field by electron streams in air (air-electron-stream) during magnetic-resonance image-guided radiation therapy (MR-IGRT). A custom-made support phantom adjusting angles between the beam central axis (CAX) and the phantom surface (termed phantom-angles), were used. Using the ViewRay system, a rectangular parallelepiped phantom placed on the support phantom, was irradiated with field sizes of 6.3 cm × 6.3 cm (FS6.3) and 12.6 cm × 12.6 cm (FS12.6) at gantry angles of 0°, 30°, and 330°, and phantom-angles of 10°, 20°, and 30°. For each beam delivery, the isocenter was located at the center of mass of the phantom and 3 Gy was delivered to the isocenter (prescription dose = 3 Gy). The doses given by the air-electron-streams were measured using the EBT3 films on the panels placed orthogonal to the direction of the magnetic field at distances of 10 and 17 cm from CAX. Two dose distributions per irradiation were measured on the panel facing the phantom surface of the incident beam (front panel) and on the panel facing the phantom surface of the beam exit (end panel). We investigated the doses by the air-electron-streams by calculating the average doses inside the circles drawn around a point of the maximum dose with radii of x cm (DRx) from the dose distributions on the panels (x = 1-5 cm). The largest value of DRx was DR1 (1.64 Gy, 55% of the prescription dose) at 10 cm distance from CAX, with FS12.6, at 30° phantom-angle and 330° gantry angle. The average difference of the DR1 at the end panels (FS12.6) between the calculations and measurements was 1.36 Gy. The average global gamma passing rate with 3%/3 mm on the dose distributions at the end panels (FS12.6) was 40.3%. The calculated dose distributions on both panels were not coincident with the measured dose distributions. The Spearman's rank correlation coefficients between the projected areas and the DRx values were always higher than 0.75 (all with p < 0.001). The doses by the air-electron-streams increased with the projected areas of the cross-sections of the treatment beams on the panels.
first_indexed 2024-12-16T09:53:57Z
format Article
id doaj.art-5aa4a6072faf49e9bfc8b6fbfd1d3f68
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-16T09:53:57Z
publishDate 2019-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-5aa4a6072faf49e9bfc8b6fbfd1d3f682022-12-21T22:35:58ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-01145e021696510.1371/journal.pone.0216965Electron streams in air during magnetic-resonance image-guided radiation therapy.Hyun Joon AnJung-In KimJong Min ParkTo investigate the undesired irradiations outside of the treatment field by electron streams in air (air-electron-stream) during magnetic-resonance image-guided radiation therapy (MR-IGRT). A custom-made support phantom adjusting angles between the beam central axis (CAX) and the phantom surface (termed phantom-angles), were used. Using the ViewRay system, a rectangular parallelepiped phantom placed on the support phantom, was irradiated with field sizes of 6.3 cm × 6.3 cm (FS6.3) and 12.6 cm × 12.6 cm (FS12.6) at gantry angles of 0°, 30°, and 330°, and phantom-angles of 10°, 20°, and 30°. For each beam delivery, the isocenter was located at the center of mass of the phantom and 3 Gy was delivered to the isocenter (prescription dose = 3 Gy). The doses given by the air-electron-streams were measured using the EBT3 films on the panels placed orthogonal to the direction of the magnetic field at distances of 10 and 17 cm from CAX. Two dose distributions per irradiation were measured on the panel facing the phantom surface of the incident beam (front panel) and on the panel facing the phantom surface of the beam exit (end panel). We investigated the doses by the air-electron-streams by calculating the average doses inside the circles drawn around a point of the maximum dose with radii of x cm (DRx) from the dose distributions on the panels (x = 1-5 cm). The largest value of DRx was DR1 (1.64 Gy, 55% of the prescription dose) at 10 cm distance from CAX, with FS12.6, at 30° phantom-angle and 330° gantry angle. The average difference of the DR1 at the end panels (FS12.6) between the calculations and measurements was 1.36 Gy. The average global gamma passing rate with 3%/3 mm on the dose distributions at the end panels (FS12.6) was 40.3%. The calculated dose distributions on both panels were not coincident with the measured dose distributions. The Spearman's rank correlation coefficients between the projected areas and the DRx values were always higher than 0.75 (all with p < 0.001). The doses by the air-electron-streams increased with the projected areas of the cross-sections of the treatment beams on the panels.https://doi.org/10.1371/journal.pone.0216965
spellingShingle Hyun Joon An
Jung-In Kim
Jong Min Park
Electron streams in air during magnetic-resonance image-guided radiation therapy.
PLoS ONE
title Electron streams in air during magnetic-resonance image-guided radiation therapy.
title_full Electron streams in air during magnetic-resonance image-guided radiation therapy.
title_fullStr Electron streams in air during magnetic-resonance image-guided radiation therapy.
title_full_unstemmed Electron streams in air during magnetic-resonance image-guided radiation therapy.
title_short Electron streams in air during magnetic-resonance image-guided radiation therapy.
title_sort electron streams in air during magnetic resonance image guided radiation therapy
url https://doi.org/10.1371/journal.pone.0216965
work_keys_str_mv AT hyunjoonan electronstreamsinairduringmagneticresonanceimageguidedradiationtherapy
AT junginkim electronstreamsinairduringmagneticresonanceimageguidedradiationtherapy
AT jongminpark electronstreamsinairduringmagneticresonanceimageguidedradiationtherapy