Redundant ADS and INS High Sensitivity Fault Detection Method

The fault detection function of GLT method is approximately proportional to the square of fault value, the value of the fault detection function is lower than the detection threshold when the soft fault is small, which leads to the low sensitivity of soft fault detection and the high rate of missing...

Full description

Bibliographic Details
Format: Article
Language:zho
Published: EDP Sciences 2020-10-01
Series:Xibei Gongye Daxue Xuebao
Subjects:
Online Access:https://www.jnwpu.org/articles/jnwpu/full_html/2020/05/jnwpu2020385p971/jnwpu2020385p971.html
_version_ 1797426782893244416
collection DOAJ
description The fault detection function of GLT method is approximately proportional to the square of fault value, the value of the fault detection function is lower than the detection threshold when the soft fault is small, which leads to the low sensitivity of soft fault detection and the high rate of missing detection. The IM-SPRT method rapidly increases the value of fault detection function above the threshold of fault detection by accumulating small soft fault values, so it has high sensitivity for soft fault detection, however, the end time of the fault cannot be judged timely, resulting in a high false alarm for fault detection. In view of the above problems, this paper proposes a high-sensitivity fault detection method for redundant systems based on GLT/IM-SPRT. This method uses the IM-SPRT method to detect weak and soft faults and sets the IM-SPRT method fault detection function value to zero by the GLT fault detection result, and isolates the fault with GLT. On this basis, a framework of high-sensitivity fault detection and isolation methods for redundant ADS and INS systems is designed. The simulation results of soft and hard fault detection and isolation of three-redundancy ADS subsystem level and INS sensor level show that the method in this paper can improve the sensitivity of fault detection and reduce the rate of missed detection.
first_indexed 2024-03-09T08:35:52Z
format Article
id doaj.art-5b352abc865f47b6ae365f1b963ffa62
institution Directory Open Access Journal
issn 1000-2758
2609-7125
language zho
last_indexed 2024-03-09T08:35:52Z
publishDate 2020-10-01
publisher EDP Sciences
record_format Article
series Xibei Gongye Daxue Xuebao
spelling doaj.art-5b352abc865f47b6ae365f1b963ffa622023-12-02T18:21:42ZzhoEDP SciencesXibei Gongye Daxue Xuebao1000-27582609-71252020-10-0138597197610.1051/jnwpu/20203850971jnwpu2020385p971Redundant ADS and INS High Sensitivity Fault Detection Method012School of Automation, Northwestern Polytechnical UniversitySchool of Automation, Northwestern Polytechnical UniversitySchool of Automation, Northwestern Polytechnical UniversityThe fault detection function of GLT method is approximately proportional to the square of fault value, the value of the fault detection function is lower than the detection threshold when the soft fault is small, which leads to the low sensitivity of soft fault detection and the high rate of missing detection. The IM-SPRT method rapidly increases the value of fault detection function above the threshold of fault detection by accumulating small soft fault values, so it has high sensitivity for soft fault detection, however, the end time of the fault cannot be judged timely, resulting in a high false alarm for fault detection. In view of the above problems, this paper proposes a high-sensitivity fault detection method for redundant systems based on GLT/IM-SPRT. This method uses the IM-SPRT method to detect weak and soft faults and sets the IM-SPRT method fault detection function value to zero by the GLT fault detection result, and isolates the fault with GLT. On this basis, a framework of high-sensitivity fault detection and isolation methods for redundant ADS and INS systems is designed. The simulation results of soft and hard fault detection and isolation of three-redundancy ADS subsystem level and INS sensor level show that the method in this paper can improve the sensitivity of fault detection and reduce the rate of missed detection.https://www.jnwpu.org/articles/jnwpu/full_html/2020/05/jnwpu2020385p971/jnwpu2020385p971.htmlredundant ads and insglt methodim-sprt methodsoft faultsimulationfault detection
spellingShingle Redundant ADS and INS High Sensitivity Fault Detection Method
Xibei Gongye Daxue Xuebao
redundant ads and ins
glt method
im-sprt method
soft fault
simulation
fault detection
title Redundant ADS and INS High Sensitivity Fault Detection Method
title_full Redundant ADS and INS High Sensitivity Fault Detection Method
title_fullStr Redundant ADS and INS High Sensitivity Fault Detection Method
title_full_unstemmed Redundant ADS and INS High Sensitivity Fault Detection Method
title_short Redundant ADS and INS High Sensitivity Fault Detection Method
title_sort redundant ads and ins high sensitivity fault detection method
topic redundant ads and ins
glt method
im-sprt method
soft fault
simulation
fault detection
url https://www.jnwpu.org/articles/jnwpu/full_html/2020/05/jnwpu2020385p971/jnwpu2020385p971.html