Effect of a Pylon Mounted Cavity-Based Flameholder on ‎the Combustor Flow Characteristics

This paper aims to study the effect of a pylon mounted cavity-based flameholder on the combustor flow ‎characteristics. Computational analysis of two different models of flameholder configurations is ‎performed. The novel cavity design 110_90 has a fore-wall ramp angle of 110 degrees and an aft-wall...

Full description

Bibliographic Details
Main Authors: S. Nayal, D. Sahoo
Format: Article
Language:English
Published: Isfahan University of Technology 2021-01-01
Series:Journal of Applied Fluid Mechanics
Subjects:
Online Access:http://jafmonline.net/JournalArchive/download?file_ID=56646&issue_ID=1015
Description
Summary:This paper aims to study the effect of a pylon mounted cavity-based flameholder on the combustor flow ‎characteristics. Computational analysis of two different models of flameholder configurations is ‎performed. The novel cavity design 110_90 has a fore-wall ramp angle of 110 degrees and an aft-wall ‎ramp angle of 90 degrees and this design which shows a comparatively better combustor performance is ‎adopted and mounted with a pylon. The flow features over the high performance base cavity 110_90 is ‎compared with the flow features obtained by adding a pylon on the upstream of the base cavity. The two ‎cases are compared qualitatively as well as quantitatively based on the temperature distribution, pressure ‎distribution, recirculation zones and drag experienced by the model. These compared parameters helped ‎us to identify whether the mentioned combination is favorable and augments the flameholder ‎performance‎‎.