An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion

Abstract The colloidal borescope, using colloidal particle motion, is used to monitor the flow velocities and directions of groundwater. It integrates advanced techniques such as microscopy, high-speed photography, and big data computing and enjoys high sensitivity at the micron level. However, In t...

Full description

Bibliographic Details
Main Authors: Fei Hu, Chang-Sheng Huang, Ji-Hong Han, Wei Huang, Xuan Li, Bao-Quan Hou, Waseem Akram, Long Li, Xue-Hao Liu, Wei Chen, Zi-Liang Zhao, Jia Zhan, Lian-Shan Xu, Hua Shan, Xiao-Zhe Li, Wen-Jing Han, Zhi-Bin Yin, Zhong-Zhong Wang, Tang-Fu Xiao
Format: Article
Language:English
Published: Nature Portfolio 2024-04-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-024-58235-z
_version_ 1797219795367624704
author Fei Hu
Chang-Sheng Huang
Ji-Hong Han
Wei Huang
Xuan Li
Bao-Quan Hou
Waseem Akram
Long Li
Xue-Hao Liu
Wei Chen
Zi-Liang Zhao
Jia Zhan
Lian-Shan Xu
Hua Shan
Xiao-Zhe Li
Wen-Jing Han
Zhi-Bin Yin
Zhong-Zhong Wang
Tang-Fu Xiao
author_facet Fei Hu
Chang-Sheng Huang
Ji-Hong Han
Wei Huang
Xuan Li
Bao-Quan Hou
Waseem Akram
Long Li
Xue-Hao Liu
Wei Chen
Zi-Liang Zhao
Jia Zhan
Lian-Shan Xu
Hua Shan
Xiao-Zhe Li
Wen-Jing Han
Zhi-Bin Yin
Zhong-Zhong Wang
Tang-Fu Xiao
author_sort Fei Hu
collection DOAJ
description Abstract The colloidal borescope, using colloidal particle motion, is used to monitor the flow velocities and directions of groundwater. It integrates advanced techniques such as microscopy, high-speed photography, and big data computing and enjoys high sensitivity at the micron level. However, In the same well, the groundwater flow velocity monitored by colloidal hole mirror is varies greatly from that obtained by conventional hydrogeological monitoring, such as pumping test. In order to solve this problem, the stability catcher and stratified packer are designed to control the interference of the vertical flow in drilling, and to monitor the flow velocity and direction of groundwater velocity at the target aquifer and target fracture. Five wells with different aquifers and different groundwater types were selected for monitoring in south-central China. The instantaneous velocity and direction are converted into east–west component and north–south component, the average velocity and direction is calculated according to the time of 10 min, and the particle trajectory diagram is established. Based on these results, it proposed a concept of cumulative flow velocity. Using curve-fitting equations, the limits of cumulative flow velocities as the monitoring time tends to infinity were then calculated as the actual flow velocities of the groundwater. The permeability coefficient of aquifer is calculated by using the fissure ratio of aquifer, hydraulic slope and flow velocity, and compared with the permeability coefficient obtained by pumping test. The results are as follows: (1) The variation coefficient of the instantaneous flow velocity measured at the same depth in the same well at different times is greater than that of the time average flow velocity and greater than that of the cumulative flow velocity. The variation coefficient of the actual velocity is the smallest, indicating that the risk of using the actual flow velocity is lower. (2) The variation coefficient of the flow rate monitored at different depths in the same well is mainly controlled by the properties of the aquifer. The more uniform water storage space in the aquifer, the smaller the variation coefficient. (3) The comparison between the permeability coefficient obtained by monitoring and the permeability coefficient obtained by pumping test shows that the flow of structural fissure water controlled by planar fissure is more surface flow, and the results are consistent. When the groundwater flow is controlled by pores and solution gaps, the flow channel is complicated, which is easy to produce turbulent flow, and the result consistency is poor. (4) According to different research accuracy requirements, different monitoring and calculation methods can be selected for different aquifers and groundwater types. Researches show that, the permeability coefficient calculated for the actual flow velocity in well DR01 is the same as that calculated for the pumping test. The aquifer characteristics reflected by the coefficient of variation of the actual flow velocity in the same aquifer are more realistic. The pumping test method obtains the comprehensive parameters of a certain aquifer, and this method can be used to monitor a certain fissure. In this paper, the new technology developed for monitoring, and the new algorithm established for data processing, can accurately obtain the flow velocity and direction of groundwater, using capsule hole mirror monitoring method. The key parameters of hydrogeology can be obtained by using one well, which can reduce the time and cost input and improve the work efficiency.
first_indexed 2024-04-24T12:39:19Z
format Article
id doaj.art-5be6f2742089493b9132a2fa81b1b581
institution Directory Open Access Journal
issn 2045-2322
language English
last_indexed 2024-04-24T12:39:19Z
publishDate 2024-04-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj.art-5be6f2742089493b9132a2fa81b1b5812024-04-07T11:18:41ZengNature PortfolioScientific Reports2045-23222024-04-0114111910.1038/s41598-024-58235-zAn improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motionFei Hu0Chang-Sheng Huang1Ji-Hong Han2Wei Huang3Xuan Li4Bao-Quan Hou5Waseem Akram6Long Li7Xue-Hao Liu8Wei Chen9Zi-Liang Zhao10Jia Zhan11Lian-Shan Xu12Hua Shan13Xiao-Zhe Li14Wen-Jing Han15Zhi-Bin Yin16Zhong-Zhong Wang17Tang-Fu Xiao18School of Environmental Science and Engineering, Guangzhou UniversityWuhan Center, China Geological SurveyWuhan Center, China Geological SurveyGuangdong Geological Survey InstituteWuhan Center, China Geological SurveyTianjin Municipal Engineering Design & Research InstituteWuhan Center, China Geological SurveyWuhan Center, China Geological SurveyWuhan Center, China Geological SurveyFourth Geological Team of Hubei Geological BureauFourth Geological Team of Hubei Geological BureauFourth Geological Team of Hubei Geological BureauThe Institute of Hydrogeologic and Engineering Geological of Wuhan, Hubei Province Geological SurveyThe Institute of Hydrogeologic and Engineering Geological of Wuhan, Hubei Province Geological SurveyWuhan Center, China Geological SurveyWuhan Center, China Geological SurveyWuhan Center, China Geological SurveyGuangdong Geological Survey InstituteSchool of Environmental Science and Engineering, Guangzhou UniversityAbstract The colloidal borescope, using colloidal particle motion, is used to monitor the flow velocities and directions of groundwater. It integrates advanced techniques such as microscopy, high-speed photography, and big data computing and enjoys high sensitivity at the micron level. However, In the same well, the groundwater flow velocity monitored by colloidal hole mirror is varies greatly from that obtained by conventional hydrogeological monitoring, such as pumping test. In order to solve this problem, the stability catcher and stratified packer are designed to control the interference of the vertical flow in drilling, and to monitor the flow velocity and direction of groundwater velocity at the target aquifer and target fracture. Five wells with different aquifers and different groundwater types were selected for monitoring in south-central China. The instantaneous velocity and direction are converted into east–west component and north–south component, the average velocity and direction is calculated according to the time of 10 min, and the particle trajectory diagram is established. Based on these results, it proposed a concept of cumulative flow velocity. Using curve-fitting equations, the limits of cumulative flow velocities as the monitoring time tends to infinity were then calculated as the actual flow velocities of the groundwater. The permeability coefficient of aquifer is calculated by using the fissure ratio of aquifer, hydraulic slope and flow velocity, and compared with the permeability coefficient obtained by pumping test. The results are as follows: (1) The variation coefficient of the instantaneous flow velocity measured at the same depth in the same well at different times is greater than that of the time average flow velocity and greater than that of the cumulative flow velocity. The variation coefficient of the actual velocity is the smallest, indicating that the risk of using the actual flow velocity is lower. (2) The variation coefficient of the flow rate monitored at different depths in the same well is mainly controlled by the properties of the aquifer. The more uniform water storage space in the aquifer, the smaller the variation coefficient. (3) The comparison between the permeability coefficient obtained by monitoring and the permeability coefficient obtained by pumping test shows that the flow of structural fissure water controlled by planar fissure is more surface flow, and the results are consistent. When the groundwater flow is controlled by pores and solution gaps, the flow channel is complicated, which is easy to produce turbulent flow, and the result consistency is poor. (4) According to different research accuracy requirements, different monitoring and calculation methods can be selected for different aquifers and groundwater types. Researches show that, the permeability coefficient calculated for the actual flow velocity in well DR01 is the same as that calculated for the pumping test. The aquifer characteristics reflected by the coefficient of variation of the actual flow velocity in the same aquifer are more realistic. The pumping test method obtains the comprehensive parameters of a certain aquifer, and this method can be used to monitor a certain fissure. In this paper, the new technology developed for monitoring, and the new algorithm established for data processing, can accurately obtain the flow velocity and direction of groundwater, using capsule hole mirror monitoring method. The key parameters of hydrogeology can be obtained by using one well, which can reduce the time and cost input and improve the work efficiency.https://doi.org/10.1038/s41598-024-58235-zGroundwater flow velocities and directionsFissure waterHydrogeologyMonitoring and calculation methodsLimit equation method
spellingShingle Fei Hu
Chang-Sheng Huang
Ji-Hong Han
Wei Huang
Xuan Li
Bao-Quan Hou
Waseem Akram
Long Li
Xue-Hao Liu
Wei Chen
Zi-Liang Zhao
Jia Zhan
Lian-Shan Xu
Hua Shan
Xiao-Zhe Li
Wen-Jing Han
Zhi-Bin Yin
Zhong-Zhong Wang
Tang-Fu Xiao
An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
Scientific Reports
Groundwater flow velocities and directions
Fissure water
Hydrogeology
Monitoring and calculation methods
Limit equation method
title An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
title_full An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
title_fullStr An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
title_full_unstemmed An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
title_short An improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
title_sort improved technology for monitoring groundwater flow velocity and direction in fractured rock system based on colloidal particles motion
topic Groundwater flow velocities and directions
Fissure water
Hydrogeology
Monitoring and calculation methods
Limit equation method
url https://doi.org/10.1038/s41598-024-58235-z
work_keys_str_mv AT feihu animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT changshenghuang animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT jihonghan animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT weihuang animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT xuanli animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT baoquanhou animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT waseemakram animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT longli animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT xuehaoliu animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT weichen animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT ziliangzhao animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT jiazhan animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT lianshanxu animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT huashan animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT xiaozheli animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT wenjinghan animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT zhibinyin animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT zhongzhongwang animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT tangfuxiao animprovedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT feihu improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT changshenghuang improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT jihonghan improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT weihuang improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT xuanli improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT baoquanhou improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT waseemakram improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT longli improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT xuehaoliu improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT weichen improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT ziliangzhao improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT jiazhan improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT lianshanxu improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT huashan improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT xiaozheli improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT wenjinghan improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT zhibinyin improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT zhongzhongwang improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion
AT tangfuxiao improvedtechnologyformonitoringgroundwaterflowvelocityanddirectioninfracturedrocksystembasedoncolloidalparticlesmotion