Finite element study of a lumbar intervertebral disc nucleus replacement device

Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with...

Full description

Bibliographic Details
Main Authors: Jessica S Coogan, W. Loren Francis, Travis D Eliason, Todd L Bredbenner, Brian D. Stemper, Narayan Yoganandan, Frank A Pintar, Daniel P. Nicolella
Format: Article
Language:English
Published: Frontiers Media S.A. 2016-12-01
Series:Frontiers in Bioengineering and Biotechnology
Subjects:
Online Access:http://journal.frontiersin.org/Journal/10.3389/fbioe.2016.00093/full
_version_ 1828416235211063296
author Jessica S Coogan
W. Loren Francis
Travis D Eliason
Todd L Bredbenner
Brian D. Stemper
Brian D. Stemper
Narayan Yoganandan
Narayan Yoganandan
Frank A Pintar
Frank A Pintar
Daniel P. Nicolella
author_facet Jessica S Coogan
W. Loren Francis
Travis D Eliason
Todd L Bredbenner
Brian D. Stemper
Brian D. Stemper
Narayan Yoganandan
Narayan Yoganandan
Frank A Pintar
Frank A Pintar
Daniel P. Nicolella
author_sort Jessica S Coogan
collection DOAJ
description Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.
first_indexed 2024-12-10T14:00:29Z
format Article
id doaj.art-5bec67cd10e54513b39ebb5a6c88c01d
institution Directory Open Access Journal
issn 2296-4185
language English
last_indexed 2024-12-10T14:00:29Z
publishDate 2016-12-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Bioengineering and Biotechnology
spelling doaj.art-5bec67cd10e54513b39ebb5a6c88c01d2022-12-22T01:45:48ZengFrontiers Media S.A.Frontiers in Bioengineering and Biotechnology2296-41852016-12-01410.3389/fbioe.2016.00093233020Finite element study of a lumbar intervertebral disc nucleus replacement deviceJessica S Coogan0W. Loren Francis1Travis D Eliason2Todd L Bredbenner3Brian D. Stemper4Brian D. Stemper5Narayan Yoganandan6Narayan Yoganandan7Frank A Pintar8Frank A Pintar9Daniel P. Nicolella10Southwest Research InstituteSpinal Stabilization TechnologiesSouthwest Research InstituteSouthwest Research InstituteMedical College of WisconsinClement J. Zablocki Veterans Affairs Medical CenterMedical College of WisconsinClement J. Zablocki Veterans Affairs Medical CenterMedical College of WisconsinClement J. Zablocki Veterans Affairs Medical CenterSouthwest Research InstituteNucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.http://journal.frontiersin.org/Journal/10.3389/fbioe.2016.00093/fullIntervertebral Discspine biomechanicsFinite Element ModelingDegenerative discNucleus replacementFinite Element Analysis
spellingShingle Jessica S Coogan
W. Loren Francis
Travis D Eliason
Todd L Bredbenner
Brian D. Stemper
Brian D. Stemper
Narayan Yoganandan
Narayan Yoganandan
Frank A Pintar
Frank A Pintar
Daniel P. Nicolella
Finite element study of a lumbar intervertebral disc nucleus replacement device
Frontiers in Bioengineering and Biotechnology
Intervertebral Disc
spine biomechanics
Finite Element Modeling
Degenerative disc
Nucleus replacement
Finite Element Analysis
title Finite element study of a lumbar intervertebral disc nucleus replacement device
title_full Finite element study of a lumbar intervertebral disc nucleus replacement device
title_fullStr Finite element study of a lumbar intervertebral disc nucleus replacement device
title_full_unstemmed Finite element study of a lumbar intervertebral disc nucleus replacement device
title_short Finite element study of a lumbar intervertebral disc nucleus replacement device
title_sort finite element study of a lumbar intervertebral disc nucleus replacement device
topic Intervertebral Disc
spine biomechanics
Finite Element Modeling
Degenerative disc
Nucleus replacement
Finite Element Analysis
url http://journal.frontiersin.org/Journal/10.3389/fbioe.2016.00093/full
work_keys_str_mv AT jessicascoogan finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT wlorenfrancis finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT travisdeliason finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT toddlbredbenner finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT briandstemper finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT briandstemper finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT narayanyoganandan finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT narayanyoganandan finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT frankapintar finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT frankapintar finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice
AT danielpnicolella finiteelementstudyofalumbarintervertebraldiscnucleusreplacementdevice