Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study
Aim: This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. Methods: Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implant...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-09-01
|
Series: | Materials |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1944/13/19/4349 |
_version_ | 1797552214852501504 |
---|---|
author | Ahmad Ibrahim Marius Heitzer Anna Bock Florian Peters Stephan Christian Möhlhenrich Frank Hölzle Ali Modabber Kristian Kniha |
author_facet | Ahmad Ibrahim Marius Heitzer Anna Bock Florian Peters Stephan Christian Möhlhenrich Frank Hölzle Ali Modabber Kristian Kniha |
author_sort | Ahmad Ibrahim |
collection | DOAJ |
description | Aim: This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. Methods: Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implants were inserted into four different artificial bone blocks representing varying bone-density groups: D1, D2, D3, and D4. Aside from the control group, three different types of defects were prepared. Using resonance frequency analysis and torque-in and -out values, the primary stability of each implant was evaluated. Results: With an increased defect size, all implant types presented reduced implant stability values measured by the implant stability quotient (ISQ) values. Loss of stability was the most pronounced around circular defects. Zirconia and bone-level implants showed the highest ISQ values, whereas tissue level titanium implants presented the lowest stability parameters. The implant insertion without any thread cut led to a small improvement in primary implant stability in all bone densities. Conclusions: Compared with implants with no peri-implant defects, the three-wall and one-wall defect usually did not provide significant loss of primary stability. A significant loss of stability should be expected when inserting implants into circular defects. Implants with a more aggressive thread distance could increase primary stability. |
first_indexed | 2024-03-10T15:56:47Z |
format | Article |
id | doaj.art-5c8406ebeb674b6ebf50610eb6061af3 |
institution | Directory Open Access Journal |
issn | 1996-1944 |
language | English |
last_indexed | 2024-03-10T15:56:47Z |
publishDate | 2020-09-01 |
publisher | MDPI AG |
record_format | Article |
series | Materials |
spelling | doaj.art-5c8406ebeb674b6ebf50610eb6061af32023-11-20T15:36:30ZengMDPI AGMaterials1996-19442020-09-011319434910.3390/ma13194349Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro StudyAhmad Ibrahim0Marius Heitzer1Anna Bock2Florian Peters3Stephan Christian Möhlhenrich4Frank Hölzle5Ali Modabber6Kristian Kniha7Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyDepartment of Orthodontics, University of Witten/Herdecke, Alfred-Herrhausen Str. 45, 58455 Witten, GermanyDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, GermanyAim: This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. Methods: Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implants were inserted into four different artificial bone blocks representing varying bone-density groups: D1, D2, D3, and D4. Aside from the control group, three different types of defects were prepared. Using resonance frequency analysis and torque-in and -out values, the primary stability of each implant was evaluated. Results: With an increased defect size, all implant types presented reduced implant stability values measured by the implant stability quotient (ISQ) values. Loss of stability was the most pronounced around circular defects. Zirconia and bone-level implants showed the highest ISQ values, whereas tissue level titanium implants presented the lowest stability parameters. The implant insertion without any thread cut led to a small improvement in primary implant stability in all bone densities. Conclusions: Compared with implants with no peri-implant defects, the three-wall and one-wall defect usually did not provide significant loss of primary stability. A significant loss of stability should be expected when inserting implants into circular defects. Implants with a more aggressive thread distance could increase primary stability.https://www.mdpi.com/1996-1944/13/19/4349dental implantdesigntitaniumzirconiaISQstability |
spellingShingle | Ahmad Ibrahim Marius Heitzer Anna Bock Florian Peters Stephan Christian Möhlhenrich Frank Hölzle Ali Modabber Kristian Kniha Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study Materials dental implant design titanium zirconia ISQ stability |
title | Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study |
title_full | Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study |
title_fullStr | Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study |
title_full_unstemmed | Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study |
title_short | Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study |
title_sort | relationship between implant geometry and primary stability in different bony defects and variant bone densities an in vitro study |
topic | dental implant design titanium zirconia ISQ stability |
url | https://www.mdpi.com/1996-1944/13/19/4349 |
work_keys_str_mv | AT ahmadibrahim relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT mariusheitzer relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT annabock relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT florianpeters relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT stephanchristianmohlhenrich relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT frankholzle relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT alimodabber relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy AT kristiankniha relationshipbetweenimplantgeometryandprimarystabilityindifferentbonydefectsandvariantbonedensitiesaninvitrostudy |