Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact.
Electroencephalography (EEG) can capture the cortical response evoked by transcranial magnetic stimulation (TMS). The TMS pulse provokes a large artefact, which obscures the cortical response in the first milliseconds after TMS. Removing this artefact remains a challenge.We delivered monophasic and...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2017-01-01
|
Series: | PLoS ONE |
Online Access: | http://europepmc.org/articles/PMC5608361?pdf=render |
_version_ | 1818450537474949120 |
---|---|
author | Leo Tomasevic Mitsuaki Takemi Hartwig Roman Siebner |
author_facet | Leo Tomasevic Mitsuaki Takemi Hartwig Roman Siebner |
author_sort | Leo Tomasevic |
collection | DOAJ |
description | Electroencephalography (EEG) can capture the cortical response evoked by transcranial magnetic stimulation (TMS). The TMS pulse provokes a large artefact, which obscures the cortical response in the first milliseconds after TMS. Removing this artefact remains a challenge.We delivered monophasic and biphasic TMS to a melon as head phantom and to four healthy participants and recorded the pulse artefact at 5 kHz with a TMS-compatible EEG system. Pulse delivery was either synchronized or non-synchronized to the clock of the EEG recording system. The effects of synchronization were tested at 10 and 20 kHz using the head phantom. We also tested the effect of a soft sheet placed between the stimulation coil and recording electrodes in both human and melon.Synchronizing TMS and data acquisition markedly reduced trial-to-trial variability of the pulse artefact in recordings from the phantom or from the scalp. Reduced trial-to-trial variability was also observed at high sampling frequencies. The use of a soft sheet reduced the variability in recordings on the head phantom, but not in human participants. Effective reduction of the trial-to-trial variability renders it possible to create an artefact template for off-line filtering. Template-based subtraction of the artefact from the EEG signals is a prerequisite to effectively recover the immediate physiological response in the stimulated cortex and inter-connected areas. |
first_indexed | 2024-12-14T20:52:53Z |
format | Article |
id | doaj.art-5ca24dc765e64c52925c608bad6785bb |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-12-14T20:52:53Z |
publishDate | 2017-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-5ca24dc765e64c52925c608bad6785bb2022-12-21T22:47:45ZengPublic Library of Science (PLoS)PLoS ONE1932-62032017-01-01129e018515410.1371/journal.pone.0185154Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact.Leo TomasevicMitsuaki TakemiHartwig Roman SiebnerElectroencephalography (EEG) can capture the cortical response evoked by transcranial magnetic stimulation (TMS). The TMS pulse provokes a large artefact, which obscures the cortical response in the first milliseconds after TMS. Removing this artefact remains a challenge.We delivered monophasic and biphasic TMS to a melon as head phantom and to four healthy participants and recorded the pulse artefact at 5 kHz with a TMS-compatible EEG system. Pulse delivery was either synchronized or non-synchronized to the clock of the EEG recording system. The effects of synchronization were tested at 10 and 20 kHz using the head phantom. We also tested the effect of a soft sheet placed between the stimulation coil and recording electrodes in both human and melon.Synchronizing TMS and data acquisition markedly reduced trial-to-trial variability of the pulse artefact in recordings from the phantom or from the scalp. Reduced trial-to-trial variability was also observed at high sampling frequencies. The use of a soft sheet reduced the variability in recordings on the head phantom, but not in human participants. Effective reduction of the trial-to-trial variability renders it possible to create an artefact template for off-line filtering. Template-based subtraction of the artefact from the EEG signals is a prerequisite to effectively recover the immediate physiological response in the stimulated cortex and inter-connected areas.http://europepmc.org/articles/PMC5608361?pdf=render |
spellingShingle | Leo Tomasevic Mitsuaki Takemi Hartwig Roman Siebner Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact. PLoS ONE |
title | Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact. |
title_full | Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact. |
title_fullStr | Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact. |
title_full_unstemmed | Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact. |
title_short | Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact. |
title_sort | synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter trial variability of the pulse artefact |
url | http://europepmc.org/articles/PMC5608361?pdf=render |
work_keys_str_mv | AT leotomasevic synchronizingthetranscranialmagneticpulsewithelectroencephalographicrecordingseffectivelyreducesintertrialvariabilityofthepulseartefact AT mitsuakitakemi synchronizingthetranscranialmagneticpulsewithelectroencephalographicrecordingseffectivelyreducesintertrialvariabilityofthepulseartefact AT hartwigromansiebner synchronizingthetranscranialmagneticpulsewithelectroencephalographicrecordingseffectivelyreducesintertrialvariabilityofthepulseartefact |