Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse

The transmitted beam of frequency diversity array (FDA) has the range–angle–time coupling property, which has essential applicative potential in angle deception and active anti-jamming. In this paper, the concept of time index within pulse is introduced. Firstly, the phase characteristics of FDA-tra...

Full description

Bibliographic Details
Main Authors: Changlin Zhou, Chunyang Wang, Jian Gong, Ming Tan, Lei Bao, Mingjie Liu
Format: Article
Language:English
Published: MDPI AG 2023-10-01
Series:Remote Sensing
Subjects:
Online Access:https://www.mdpi.com/2072-4292/15/21/5171
_version_ 1797631331939647488
author Changlin Zhou
Chunyang Wang
Jian Gong
Ming Tan
Lei Bao
Mingjie Liu
author_facet Changlin Zhou
Chunyang Wang
Jian Gong
Ming Tan
Lei Bao
Mingjie Liu
author_sort Changlin Zhou
collection DOAJ
description The transmitted beam of frequency diversity array (FDA) has the range–angle–time coupling property, which has essential applicative potential in angle deception and active anti-jamming. In this paper, the concept of time index within pulse is introduced. Firstly, the phase characteristics of FDA-transmitted signals based on the time index within pulse concept are studied. Then, the deceptive angle performance of FDA-transmitted signals is discussed. The theoretical analysis and simulation results show that the phase characteristics of the FDA signal are not related to the range, but to the time index within pulse. With the phase center as the reference point, the phase is equal as long as the time index within the pulse is the same. Angle deception and active anti-jamming can be achieved using the optimized frequency increment of each FDA.
first_indexed 2024-03-11T11:22:14Z
format Article
id doaj.art-5caa93298df74b5a8f60183dfd59d0ae
institution Directory Open Access Journal
issn 2072-4292
language English
last_indexed 2024-03-11T11:22:14Z
publishDate 2023-10-01
publisher MDPI AG
record_format Article
series Remote Sensing
spelling doaj.art-5caa93298df74b5a8f60183dfd59d0ae2023-11-10T15:11:16ZengMDPI AGRemote Sensing2072-42922023-10-011521517110.3390/rs15215171Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within PulseChanglin Zhou0Chunyang Wang1Jian Gong2Ming Tan3Lei Bao4Mingjie Liu5Air and Missile Defense College, Air Force Engineering University, Xi’an 710051, ChinaAir and Missile Defense College, Air Force Engineering University, Xi’an 710051, ChinaAir and Missile Defense College, Air Force Engineering University, Xi’an 710051, ChinaCollege of Information and Communication, National University of Defense Technology, Wuhan 430010, ChinaTest and Training Base, National University of Defense Technology, Xi’an 710106, ChinaAir and Missile Defense College, Air Force Engineering University, Xi’an 710051, ChinaThe transmitted beam of frequency diversity array (FDA) has the range–angle–time coupling property, which has essential applicative potential in angle deception and active anti-jamming. In this paper, the concept of time index within pulse is introduced. Firstly, the phase characteristics of FDA-transmitted signals based on the time index within pulse concept are studied. Then, the deceptive angle performance of FDA-transmitted signals is discussed. The theoretical analysis and simulation results show that the phase characteristics of the FDA signal are not related to the range, but to the time index within pulse. With the phase center as the reference point, the phase is equal as long as the time index within the pulse is the same. Angle deception and active anti-jamming can be achieved using the optimized frequency increment of each FDA.https://www.mdpi.com/2072-4292/15/21/5171frequency diversity array (FDA)time index within pulsephase centerangle deceptionactive anti-jamming
spellingShingle Changlin Zhou
Chunyang Wang
Jian Gong
Ming Tan
Lei Bao
Mingjie Liu
Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse
Remote Sensing
frequency diversity array (FDA)
time index within pulse
phase center
angle deception
active anti-jamming
title Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse
title_full Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse
title_fullStr Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse
title_full_unstemmed Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse
title_short Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse
title_sort phase characteristics and angle deception of frequency diversity array transmitted signals based on time index within pulse
topic frequency diversity array (FDA)
time index within pulse
phase center
angle deception
active anti-jamming
url https://www.mdpi.com/2072-4292/15/21/5171
work_keys_str_mv AT changlinzhou phasecharacteristicsandangledeceptionoffrequencydiversityarraytransmittedsignalsbasedontimeindexwithinpulse
AT chunyangwang phasecharacteristicsandangledeceptionoffrequencydiversityarraytransmittedsignalsbasedontimeindexwithinpulse
AT jiangong phasecharacteristicsandangledeceptionoffrequencydiversityarraytransmittedsignalsbasedontimeindexwithinpulse
AT mingtan phasecharacteristicsandangledeceptionoffrequencydiversityarraytransmittedsignalsbasedontimeindexwithinpulse
AT leibao phasecharacteristicsandangledeceptionoffrequencydiversityarraytransmittedsignalsbasedontimeindexwithinpulse
AT mingjieliu phasecharacteristicsandangledeceptionoffrequencydiversityarraytransmittedsignalsbasedontimeindexwithinpulse