Data on wastewater treatment plant by using wetland method, Babol, Iran
Date in this paper highlights the applications of constructed horizontal surface flow (HF-CW) wetland with two different local plants (Louis latifoila and Phragmites -australis (Cav.) Trin) at the wastewater treatment plant in Babol city. This system was designed as an advanced treatment unit in fie...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2018-02-01
|
Series: | Data in Brief |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352340917307291 |
_version_ | 1818109492681768960 |
---|---|
author | Yousef Dadban Shahamat Hosseinali Asgharnia Laleh R. Kalankesh Mehdi hosanpour |
author_facet | Yousef Dadban Shahamat Hosseinali Asgharnia Laleh R. Kalankesh Mehdi hosanpour |
author_sort | Yousef Dadban Shahamat |
collection | DOAJ |
description | Date in this paper highlights the applications of constructed horizontal surface flow (HF-CW) wetland with two different local plants (Louis latifoila and Phragmites -australis (Cav.) Trin) at the wastewater treatment plant in Babol city. This system was designed as an advanced treatment unit in field scale after the treatment plant. Parameters such as Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Turbidity, Biological Oxygen Demand (BOD) and Chemical Oxygen Demand (COD), were investigated. The result shows that treatment efficiency increases with the passage of time. The efficiency of Phragmites planted setups in open environment was fairly good for all studied parameters (28.6% of TDS, 94.4% for TSS, 79.8% for turbidity, 93.7% for BOD and 82.6% for COD). The efficiency of the latifoila set up was also good, but lower than that of Phragmites (26.5% of TDS, 76.9% for TSS, 71.5% for turbidity, 79.1 for BOD and 68.8% for COD). In brief, the obtained dates show that using local plants in (HF-CW) wetland not only effectively reduces various contaminants from the effluent of the wastewater according to Effluent Guideline regulations (WHO & EPA), but it is also a cost- effective and environmentally friendly method. Also, it was calculated that in full scale operation [time (1 day) and a depth (0.3 m)], 8 ha of wetland was needed. Keywords: BOD, Babol, COD, Horizontal subsurface flow wetland, TSS, TSD |
first_indexed | 2024-12-11T02:32:07Z |
format | Article |
id | doaj.art-5ccc40cf5ff74230a06338617247b984 |
institution | Directory Open Access Journal |
issn | 2352-3409 |
language | English |
last_indexed | 2024-12-11T02:32:07Z |
publishDate | 2018-02-01 |
publisher | Elsevier |
record_format | Article |
series | Data in Brief |
spelling | doaj.art-5ccc40cf5ff74230a06338617247b9842022-12-22T01:23:48ZengElsevierData in Brief2352-34092018-02-011610561061Data on wastewater treatment plant by using wetland method, Babol, IranYousef Dadban Shahamat0Hosseinali Asgharnia1Laleh R. Kalankesh2Mehdi hosanpour3Environmental Health Research Center, Golestan University of Medical Sciences, Gorgan, IranDepartment of Environmental Health Engineering, Babol University of Medical Sciences, Babol, Iran; Corresponding author.Department of Environmental Health Science, Student Research Committe, Health Sciences Research Center, School of Public Health, Mazandaran University of Medical Sciences, Sari, IranDepartment of Environment and Energy, West Tehran Branch, Islamic Azad University, Tehran, IranDate in this paper highlights the applications of constructed horizontal surface flow (HF-CW) wetland with two different local plants (Louis latifoila and Phragmites -australis (Cav.) Trin) at the wastewater treatment plant in Babol city. This system was designed as an advanced treatment unit in field scale after the treatment plant. Parameters such as Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Turbidity, Biological Oxygen Demand (BOD) and Chemical Oxygen Demand (COD), were investigated. The result shows that treatment efficiency increases with the passage of time. The efficiency of Phragmites planted setups in open environment was fairly good for all studied parameters (28.6% of TDS, 94.4% for TSS, 79.8% for turbidity, 93.7% for BOD and 82.6% for COD). The efficiency of the latifoila set up was also good, but lower than that of Phragmites (26.5% of TDS, 76.9% for TSS, 71.5% for turbidity, 79.1 for BOD and 68.8% for COD). In brief, the obtained dates show that using local plants in (HF-CW) wetland not only effectively reduces various contaminants from the effluent of the wastewater according to Effluent Guideline regulations (WHO & EPA), but it is also a cost- effective and environmentally friendly method. Also, it was calculated that in full scale operation [time (1 day) and a depth (0.3 m)], 8 ha of wetland was needed. Keywords: BOD, Babol, COD, Horizontal subsurface flow wetland, TSS, TSDhttp://www.sciencedirect.com/science/article/pii/S2352340917307291 |
spellingShingle | Yousef Dadban Shahamat Hosseinali Asgharnia Laleh R. Kalankesh Mehdi hosanpour Data on wastewater treatment plant by using wetland method, Babol, Iran Data in Brief |
title | Data on wastewater treatment plant by using wetland method, Babol, Iran |
title_full | Data on wastewater treatment plant by using wetland method, Babol, Iran |
title_fullStr | Data on wastewater treatment plant by using wetland method, Babol, Iran |
title_full_unstemmed | Data on wastewater treatment plant by using wetland method, Babol, Iran |
title_short | Data on wastewater treatment plant by using wetland method, Babol, Iran |
title_sort | data on wastewater treatment plant by using wetland method babol iran |
url | http://www.sciencedirect.com/science/article/pii/S2352340917307291 |
work_keys_str_mv | AT yousefdadbanshahamat dataonwastewatertreatmentplantbyusingwetlandmethodbaboliran AT hosseinaliasgharnia dataonwastewatertreatmentplantbyusingwetlandmethodbaboliran AT lalehrkalankesh dataonwastewatertreatmentplantbyusingwetlandmethodbaboliran AT mehdihosanpour dataonwastewatertreatmentplantbyusingwetlandmethodbaboliran |