Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave
This paper presents a novel and analytical approach to identifying a lightning strike after it has struck an overhead transmission line. The identification method is mainly based on the traveling waves' time-domain parameters, such as polarity, amplitude, and half-wavelength. The main differenc...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2016-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/7574285/ |
_version_ | 1818927803909799936 |
---|---|
author | Yadong Liu Gehao Sheng Yue Hu Yong Qian Xiuchen Jiang Robert C. Qiu Yilu Liu |
author_facet | Yadong Liu Gehao Sheng Yue Hu Yong Qian Xiuchen Jiang Robert C. Qiu Yilu Liu |
author_sort | Yadong Liu |
collection | DOAJ |
description | This paper presents a novel and analytical approach to identifying a lightning strike after it has struck an overhead transmission line. The identification method is mainly based on the traveling waves' time-domain parameters, such as polarity, amplitude, and half-wavelength. The main differences in these parameters across different strike types are analyzed. Subsequently, a robust identification algorithm is proposed. An instrumentation system is implemented to verify the algorithm. The overall performances of the instrumentation system and the methodology are demonstrated using an on-site application with excellent results. |
first_indexed | 2024-12-20T03:18:49Z |
format | Article |
id | doaj.art-5d7f8008fd0f4b75bff6480633479a94 |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-12-20T03:18:49Z |
publishDate | 2016-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-5d7f8008fd0f4b75bff6480633479a942022-12-21T19:55:16ZengIEEEIEEE Access2169-35362016-01-0147241725010.1109/ACCESS.2016.26127027574285Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling WaveYadong Liu0https://orcid.org/0000-0002-7921-6757Gehao Sheng1Yue Hu2Yong Qian3Xiuchen Jiang4Robert C. Qiu5Yilu Liu6School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaSchool of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaSchool of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaSchool of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaSchool of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaDepartment of Electrical and Computer Engineering, Tennessee Technological University, Cookeville, TN, USADepartment of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN, USAThis paper presents a novel and analytical approach to identifying a lightning strike after it has struck an overhead transmission line. The identification method is mainly based on the traveling waves' time-domain parameters, such as polarity, amplitude, and half-wavelength. The main differences in these parameters across different strike types are analyzed. Subsequently, a robust identification algorithm is proposed. An instrumentation system is implemented to verify the algorithm. The overall performances of the instrumentation system and the methodology are demonstrated using an on-site application with excellent results.https://ieeexplore.ieee.org/document/7574285/Back flashovershielding failurecurrent traveling waveinstrumentation systemamplitudepolarity |
spellingShingle | Yadong Liu Gehao Sheng Yue Hu Yong Qian Xiuchen Jiang Robert C. Qiu Yilu Liu Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave IEEE Access Back flashover shielding failure current traveling wave instrumentation system amplitude polarity |
title | Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave |
title_full | Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave |
title_fullStr | Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave |
title_full_unstemmed | Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave |
title_short | Identification of Lightning Strike on 500-kV Transmission Line Based on the Time-Domain Parameters of a Traveling Wave |
title_sort | identification of lightning strike on 500 kv transmission line based on the time domain parameters of a traveling wave |
topic | Back flashover shielding failure current traveling wave instrumentation system amplitude polarity |
url | https://ieeexplore.ieee.org/document/7574285/ |
work_keys_str_mv | AT yadongliu identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave AT gehaosheng identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave AT yuehu identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave AT yongqian identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave AT xiuchenjiang identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave AT robertcqiu identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave AT yiluliu identificationoflightningstrikeon500kvtransmissionlinebasedonthetimedomainparametersofatravelingwave |