ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS

This paper describes an estimation method of decreasing losses of active power in power transformers with voltage 10(6)/0,4 kV after installation of devices of reactive power compensation on output side depending on voltage level, connected to capacity devices, taking into account dielectric loss in...

Full description

Bibliographic Details
Main Authors: V. N. Radkevich, M. N. Tarasova
Format: Article
Language:Russian
Published: Belarusian National Technical University 2014-10-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/816
_version_ 1797879808530579456
author V. N. Radkevich
M. N. Tarasova
author_facet V. N. Radkevich
M. N. Tarasova
author_sort V. N. Radkevich
collection DOAJ
description This paper describes an estimation method of decreasing losses of active power in power transformers with voltage 10(6)/0,4 kV after installation of devices of reactive power compensation on output side depending on voltage level, connected to capacity devices, taking into account dielectric loss in capacitors. Analysis of functional dependences was carried out. Investigation of function with a help of derivations was carried out. Points of function extremum and also its intervals of rise and fall rates were founded. This paper describes graphic investigation of obtained functional dependence, which is introduced by quartic polynominal. It is established that decreasing of losses of active power depends on technical parameters and load factor of transformer, coefficient of loading power of electricity consumers, voltage value connected to capacitor unit.Using obtained functional dependences, calculations for the main size-types of power transformers with voltage 10(6)/0,4 kV serie ТМГ 11 and ТМГ12 were done. It is established that depending on technical characteristics of certain transformer, coefficient of its loading and power, there is a definite value of deviation of real voltage value from working voltage of capacitor installation when it will be observed positive technical and economical effect from installed capacitor battery unit. For taken value of loading coefficient and transformer’s power the maximum decrease of losses of active power takes place under voltage directed to capacitor unit, which is lower then nominal value. For all taken size-types of power transformers the argument of investigating function for its maximal value is out of standard permissible of voltage deviations from nominal value.These functional dependents can be used for preliminary calculations, which are needed for making decision on compensation of reactive power in electric power supply systems of industrial objects. Their consideration allows more accurately evaluate technical and economical effect from installation of capacitor’s batteries in electrical networks with voltage up to 1 kV.
first_indexed 2024-04-10T02:53:09Z
format Article
id doaj.art-5d8d31ec06694378b2e31d71a20b2749
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:53:09Z
publishDate 2014-10-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-5d8d31ec06694378b2e31d71a20b27492023-03-13T07:41:49ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412014-10-01052737808ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORSV. N. Radkevich0M. N. Tarasova1Белорусский национальный технический университетБелорусский национальный технический университетThis paper describes an estimation method of decreasing losses of active power in power transformers with voltage 10(6)/0,4 kV after installation of devices of reactive power compensation on output side depending on voltage level, connected to capacity devices, taking into account dielectric loss in capacitors. Analysis of functional dependences was carried out. Investigation of function with a help of derivations was carried out. Points of function extremum and also its intervals of rise and fall rates were founded. This paper describes graphic investigation of obtained functional dependence, which is introduced by quartic polynominal. It is established that decreasing of losses of active power depends on technical parameters and load factor of transformer, coefficient of loading power of electricity consumers, voltage value connected to capacitor unit.Using obtained functional dependences, calculations for the main size-types of power transformers with voltage 10(6)/0,4 kV serie ТМГ 11 and ТМГ12 were done. It is established that depending on technical characteristics of certain transformer, coefficient of its loading and power, there is a definite value of deviation of real voltage value from working voltage of capacitor installation when it will be observed positive technical and economical effect from installed capacitor battery unit. For taken value of loading coefficient and transformer’s power the maximum decrease of losses of active power takes place under voltage directed to capacitor unit, which is lower then nominal value. For all taken size-types of power transformers the argument of investigating function for its maximal value is out of standard permissible of voltage deviations from nominal value.These functional dependents can be used for preliminary calculations, which are needed for making decision on compensation of reactive power in electric power supply systems of industrial objects. Their consideration allows more accurately evaluate technical and economical effect from installation of capacitor’s batteries in electrical networks with voltage up to 1 kV.https://energy.bntu.by/jour/article/view/816трансформаторактивная мощностьбатарея конденсаторовконденсаторная установка
spellingShingle V. N. Radkevich
M. N. Tarasova
ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
трансформатор
активная мощность
батарея конденсаторов
конденсаторная установка
title ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS
title_full ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS
title_fullStr ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS
title_full_unstemmed ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS
title_short ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS
title_sort estimation of decreasing losses of active power in transformers in setting battery of low voltage capacitors
topic трансформатор
активная мощность
батарея конденсаторов
конденсаторная установка
url https://energy.bntu.by/jour/article/view/816
work_keys_str_mv AT vnradkevich estimationofdecreasinglossesofactivepowerintransformersinsettingbatteryoflowvoltagecapacitors
AT mntarasova estimationofdecreasinglossesofactivepowerintransformersinsettingbatteryoflowvoltagecapacitors