Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements

When knee bony tumors appear, arthrodesis is one terapeutic option after tumor block resection. The implant is composed of an intramedular nail with four interlocking pins. The whole implant is manufactured using a titanium alloy (Ti-6Al-4V). The spacer has the capability of be extended from 20 cm...

Full description

Bibliographic Details
Main Authors: Víctor Araujo, Víctor Domínguez, José Martínez, Genaro Rico, Ernesto Delgado, Daniela Alcántara, Azucena Noriega, Paulina Carbajal
Format: Article
Language:English
Published: Universidad de Antioquia 2013-03-01
Series:Revista Facultad de Ingeniería Universidad de Antioquia
Subjects:
Online Access:https://revistas.udea.edu.co/index.php/ingenieria/article/view/14779
_version_ 1797861616937598976
author Víctor Araujo
Víctor Domínguez
José Martínez
Genaro Rico
Ernesto Delgado
Daniela Alcántara
Azucena Noriega
Paulina Carbajal
author_facet Víctor Araujo
Víctor Domínguez
José Martínez
Genaro Rico
Ernesto Delgado
Daniela Alcántara
Azucena Noriega
Paulina Carbajal
author_sort Víctor Araujo
collection DOAJ
description When knee bony tumors appear, arthrodesis is one terapeutic option after tumor block resection. The implant is composed of an intramedular nail with four interlocking pins. The whole implant is manufactured using a titanium alloy (Ti-6Al-4V). The spacer has the capability of be extended from 20 cm up to 30 cm, and it is used as a definitively treatment. The use of this item reports good result despite the fact that affected limb is arthrodesed. However, it has a great interest to study the influence of bone tumor resection size on the implant integrity. To perform this research work, we developed a finite element model of the complex femur-implant-tibia, by means of Ansys software version 11 (Ansys, Inc). The loading conditions used during modeling process correspond to those occurring during midstance phase of gait. We analyzed six cases, varying spacer length: 20 cm, 22 cm, 24 cm, 26 cm, 28 cm and 30 cm. Our results indicate that there is no fracture failure risk within the implant when varying spacer length over the range previously stated, since we did not find significative difference on stress levels within the implant. However, stress levels of inter locking tibial pins are increased considerably for a resection of 24 cm or higher, this fact could lead us to implant loosening.
first_indexed 2024-04-09T22:07:08Z
format Article
id doaj.art-5dda86ab588c44c5b8ac5a53fddd4f8d
institution Directory Open Access Journal
issn 0120-6230
2422-2844
language English
last_indexed 2024-04-09T22:07:08Z
publishDate 2013-03-01
publisher Universidad de Antioquia
record_format Article
series Revista Facultad de Ingeniería Universidad de Antioquia
spelling doaj.art-5dda86ab588c44c5b8ac5a53fddd4f8d2023-03-23T12:35:37ZengUniversidad de AntioquiaRevista Facultad de Ingeniería Universidad de Antioquia0120-62302422-28442013-03-0153Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elementsVíctor Araujo0Víctor Domínguez1José Martínez2Genaro Rico3Ernesto Delgado4Daniela Alcántara5Azucena Noriega6Paulina Carbajal7National Institute of RehabilitationNational Institute of RehabilitationNational Polytechnic InstituteNational Institute of RehabilitationNational Institute of RehabilitationTechnological Institute of Higher Studies of MonterreyTechnological Institute of Higher Studies of MonterreyTechnological Institute of Higher Studies of Monterrey When knee bony tumors appear, arthrodesis is one terapeutic option after tumor block resection. The implant is composed of an intramedular nail with four interlocking pins. The whole implant is manufactured using a titanium alloy (Ti-6Al-4V). The spacer has the capability of be extended from 20 cm up to 30 cm, and it is used as a definitively treatment. The use of this item reports good result despite the fact that affected limb is arthrodesed. However, it has a great interest to study the influence of bone tumor resection size on the implant integrity. To perform this research work, we developed a finite element model of the complex femur-implant-tibia, by means of Ansys software version 11 (Ansys, Inc). The loading conditions used during modeling process correspond to those occurring during midstance phase of gait. We analyzed six cases, varying spacer length: 20 cm, 22 cm, 24 cm, 26 cm, 28 cm and 30 cm. Our results indicate that there is no fracture failure risk within the implant when varying spacer length over the range previously stated, since we did not find significative difference on stress levels within the implant. However, stress levels of inter locking tibial pins are increased considerably for a resection of 24 cm or higher, this fact could lead us to implant loosening. https://revistas.udea.edu.co/index.php/ingenieria/article/view/14779spacer arthrodesisfinite Element
spellingShingle Víctor Araujo
Víctor Domínguez
José Martínez
Genaro Rico
Ernesto Delgado
Daniela Alcántara
Azucena Noriega
Paulina Carbajal
Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
Revista Facultad de Ingeniería Universidad de Antioquia
spacer
arthrodesis
finite Element
title Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
title_full Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
title_fullStr Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
title_full_unstemmed Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
title_short Biomechanical Analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
title_sort biomechanical analysis of a spacer for knee neoplasms in terms of resection extension by means of finite elements
topic spacer
arthrodesis
finite Element
url https://revistas.udea.edu.co/index.php/ingenieria/article/view/14779
work_keys_str_mv AT victoraraujo biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT victordominguez biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT josemartinez biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT genarorico biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT ernestodelgado biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT danielaalcantara biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT azucenanoriega biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements
AT paulinacarbajal biomechanicalanalysisofaspacerforkneeneoplasmsintermsofresectionextensionbymeansoffiniteelements