Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria

Context: Diagnostic reference level (DRL) is the first step in the optimization process to manage patient dose corresponding with the medical purpose. Aim: The objective of this study was to develop local DRL for computed tomography (CT) of the head and abdomen in adult patients in four CT centers i...

Full description

Bibliographic Details
Main Authors: Anwuli Christiana Tobi, Chukwuka Emmanuel Mokobia, Joyce Ekeme Ikubor, Akintayo Daniel Omojola, Maryann Etim Ekpo, Anita Franklin Akpolile
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2021-01-01
Series:Journal of Radiation and Cancer Research
Subjects:
Online Access:http://www.journalrcr.org/article.asp?issn=2588-9273;year=2021;volume=12;issue=2;spage=46;epage=52;aulast=Tobi
_version_ 1819143104936017920
author Anwuli Christiana Tobi
Chukwuka Emmanuel Mokobia
Joyce Ekeme Ikubor
Akintayo Daniel Omojola
Maryann Etim Ekpo
Anita Franklin Akpolile
author_facet Anwuli Christiana Tobi
Chukwuka Emmanuel Mokobia
Joyce Ekeme Ikubor
Akintayo Daniel Omojola
Maryann Etim Ekpo
Anita Franklin Akpolile
author_sort Anwuli Christiana Tobi
collection DOAJ
description Context: Diagnostic reference level (DRL) is the first step in the optimization process to manage patient dose corresponding with the medical purpose. Aim: The objective of this study was to develop local DRL for computed tomography (CT) of the head and abdomen in adult patients in four CT centers in South-South Nigeria. Materials and Methods: A prospective, cross-sectional study of 546 adult patients that underwent CT examination of the head and abdomen from 2018 to 2020 using four different CT scanners. Volume CT dose index (CTDIvol) and dose length product (DLP) of contrast and non-contrast CT examinations of the head and abdomen were collated and the 50th percentile DRL was determined and compared to other published DRLs. Results: The 50th percentile CTDIvol/DLP for non-contrast head CT examination for centers A, B, C, and D was 75.3 mGy/1776.6 mGy.cm, 21.8 mGy/457 mGy.cm, 17.4 mGy/373.6 mGy.cm, and 29.6 mGy/628.5 mGy.cm, respectively. The 50th percentile CTDIvol/DLP for contrast head CT examination for centers A, B, C, and D was 150.6 mGy/3326.2 mGy.cm, 41.4 mGy/832.4 mGy.cm, 35.6 mGy/653.6 mGy.cm, and 77.9 mGy/1458.4 mGy.cm, respectively. The 50th percentile CTDIvol/DLP for non-contrast abdomen CT examination for centers A and B was 22.8 mGy/1488.5 mGy.cm and 7.9 mGy/302.3 mGy.cm, respectively. The 50th percentile CTDIvol/DLP for contrast abdomen CT examination for centers B and C was 19.6 mGy/825.7 mGy.cm and 31.5 mGy/1555.5 mGy.cm, respectively. There was correlation between contrast and non-contrast CTDI (P = 0.003) and DLP (P = 0.025) for the head. Conclusion: Wide variations CTDIvol and DLP values were observed among the centers for similar body part CT examinations.
first_indexed 2024-12-22T12:20:57Z
format Article
id doaj.art-5eb96f164dc74e9f83d5076943203a67
institution Directory Open Access Journal
issn 2588-9273
2468-9203
language English
last_indexed 2024-12-22T12:20:57Z
publishDate 2021-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Radiation and Cancer Research
spelling doaj.art-5eb96f164dc74e9f83d5076943203a672022-12-21T18:25:59ZengWolters Kluwer Medknow PublicationsJournal of Radiation and Cancer Research2588-92732468-92032021-01-01122465210.4103/jrcr.jrcr_67_20Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South NigeriaAnwuli Christiana TobiChukwuka Emmanuel MokobiaJoyce Ekeme IkuborAkintayo Daniel OmojolaMaryann Etim EkpoAnita Franklin AkpolileContext: Diagnostic reference level (DRL) is the first step in the optimization process to manage patient dose corresponding with the medical purpose. Aim: The objective of this study was to develop local DRL for computed tomography (CT) of the head and abdomen in adult patients in four CT centers in South-South Nigeria. Materials and Methods: A prospective, cross-sectional study of 546 adult patients that underwent CT examination of the head and abdomen from 2018 to 2020 using four different CT scanners. Volume CT dose index (CTDIvol) and dose length product (DLP) of contrast and non-contrast CT examinations of the head and abdomen were collated and the 50th percentile DRL was determined and compared to other published DRLs. Results: The 50th percentile CTDIvol/DLP for non-contrast head CT examination for centers A, B, C, and D was 75.3 mGy/1776.6 mGy.cm, 21.8 mGy/457 mGy.cm, 17.4 mGy/373.6 mGy.cm, and 29.6 mGy/628.5 mGy.cm, respectively. The 50th percentile CTDIvol/DLP for contrast head CT examination for centers A, B, C, and D was 150.6 mGy/3326.2 mGy.cm, 41.4 mGy/832.4 mGy.cm, 35.6 mGy/653.6 mGy.cm, and 77.9 mGy/1458.4 mGy.cm, respectively. The 50th percentile CTDIvol/DLP for non-contrast abdomen CT examination for centers A and B was 22.8 mGy/1488.5 mGy.cm and 7.9 mGy/302.3 mGy.cm, respectively. The 50th percentile CTDIvol/DLP for contrast abdomen CT examination for centers B and C was 19.6 mGy/825.7 mGy.cm and 31.5 mGy/1555.5 mGy.cm, respectively. There was correlation between contrast and non-contrast CTDI (P = 0.003) and DLP (P = 0.025) for the head. Conclusion: Wide variations CTDIvol and DLP values were observed among the centers for similar body part CT examinations.http://www.journalrcr.org/article.asp?issn=2588-9273;year=2021;volume=12;issue=2;spage=46;epage=52;aulast=Tobicomputed tomographydose-length productdiagnostic reference levelvolume computed tomography dose index
spellingShingle Anwuli Christiana Tobi
Chukwuka Emmanuel Mokobia
Joyce Ekeme Ikubor
Akintayo Daniel Omojola
Maryann Etim Ekpo
Anita Franklin Akpolile
Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria
Journal of Radiation and Cancer Research
computed tomography
dose-length product
diagnostic reference level
volume computed tomography dose index
title Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria
title_full Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria
title_fullStr Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria
title_full_unstemmed Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria
title_short Diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in South-South Nigeria
title_sort diagnostic reference levels for head and abdominal computed tomography of adult patients in selected states in south south nigeria
topic computed tomography
dose-length product
diagnostic reference level
volume computed tomography dose index
url http://www.journalrcr.org/article.asp?issn=2588-9273;year=2021;volume=12;issue=2;spage=46;epage=52;aulast=Tobi
work_keys_str_mv AT anwulichristianatobi diagnosticreferencelevelsforheadandabdominalcomputedtomographyofadultpatientsinselectedstatesinsouthsouthnigeria
AT chukwukaemmanuelmokobia diagnosticreferencelevelsforheadandabdominalcomputedtomographyofadultpatientsinselectedstatesinsouthsouthnigeria
AT joyceekemeikubor diagnosticreferencelevelsforheadandabdominalcomputedtomographyofadultpatientsinselectedstatesinsouthsouthnigeria
AT akintayodanielomojola diagnosticreferencelevelsforheadandabdominalcomputedtomographyofadultpatientsinselectedstatesinsouthsouthnigeria
AT maryannetimekpo diagnosticreferencelevelsforheadandabdominalcomputedtomographyofadultpatientsinselectedstatesinsouthsouthnigeria
AT anitafranklinakpolile diagnosticreferencelevelsforheadandabdominalcomputedtomographyofadultpatientsinselectedstatesinsouthsouthnigeria