High-temperature service life tests of full-size thermosyphons
During past two decades, at temperature 240-265°C, resource tests were carried out on 19 thermosyphons of full-scale sizes: 45х4 mm in diameter, 4.92 m in length. The thermosyphons were prepared with varying preliminary surface treatment methods, composition of the aqueous solution to be poured into...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_05009.pdf |
_version_ | 1831808897826947072 |
---|---|
author | Balunov Boris Egorov Mikle |
author_facet | Balunov Boris Egorov Mikle |
author_sort | Balunov Boris |
collection | DOAJ |
description | During past two decades, at temperature 240-265°C, resource tests were carried out on 19 thermosyphons of full-scale sizes: 45х4 mm in diameter, 4.92 m in length. The thermosyphons were prepared with varying preliminary surface treatment methods, composition of the aqueous solution to be poured into the thermosyphons, location of titanium chips in the perforated capsules under the lid of the thermosyphons. With a period of 1 to 3 years, thermosyphons were removed from testing system for 30 hours to control the vacuum by thermal method that does not require depressurization. At the last control experiment, four thermosyphons are depressurized for the following purposes: to check the condition of their internal surface in different zones along the length; for the chemical analysis of the aqueous solution poured from them; to determine the structure and characteristics of the mechanical properties of the thermosyphon metal. The main aim of the tests is to justify maintaining the structure and mechanical properties of the metal for a long time, keeping a vacuum of 90-95% inside the thermosyphon, ensuring high heat transfer characteristics of the boiling operating mode of thermosyphons. |
first_indexed | 2024-12-22T20:31:09Z |
format | Article |
id | doaj.art-5f0ffd1b838e40a3a169dc1c0894f29c |
institution | Directory Open Access Journal |
issn | 2267-1242 |
language | English |
last_indexed | 2024-12-22T20:31:09Z |
publishDate | 2019-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | E3S Web of Conferences |
spelling | doaj.art-5f0ffd1b838e40a3a169dc1c0894f29c2022-12-21T18:13:35ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011400500910.1051/e3sconf/201914005009e3sconf_eece18_05009High-temperature service life tests of full-size thermosyphonsBalunov Boris0Egorov MikleJoint-Stock Company “I.I. Polzunov Scientific and Development Association on Research and Design of Power Equipment”During past two decades, at temperature 240-265°C, resource tests were carried out on 19 thermosyphons of full-scale sizes: 45х4 mm in diameter, 4.92 m in length. The thermosyphons were prepared with varying preliminary surface treatment methods, composition of the aqueous solution to be poured into the thermosyphons, location of titanium chips in the perforated capsules under the lid of the thermosyphons. With a period of 1 to 3 years, thermosyphons were removed from testing system for 30 hours to control the vacuum by thermal method that does not require depressurization. At the last control experiment, four thermosyphons are depressurized for the following purposes: to check the condition of their internal surface in different zones along the length; for the chemical analysis of the aqueous solution poured from them; to determine the structure and characteristics of the mechanical properties of the thermosyphon metal. The main aim of the tests is to justify maintaining the structure and mechanical properties of the metal for a long time, keeping a vacuum of 90-95% inside the thermosyphon, ensuring high heat transfer characteristics of the boiling operating mode of thermosyphons.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_05009.pdf |
spellingShingle | Balunov Boris Egorov Mikle High-temperature service life tests of full-size thermosyphons E3S Web of Conferences |
title | High-temperature service life tests of full-size thermosyphons |
title_full | High-temperature service life tests of full-size thermosyphons |
title_fullStr | High-temperature service life tests of full-size thermosyphons |
title_full_unstemmed | High-temperature service life tests of full-size thermosyphons |
title_short | High-temperature service life tests of full-size thermosyphons |
title_sort | high temperature service life tests of full size thermosyphons |
url | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_05009.pdf |
work_keys_str_mv | AT balunovboris hightemperatureservicelifetestsoffullsizethermosyphons AT egorovmikle hightemperatureservicelifetestsoffullsizethermosyphons |