High-temperature service life tests of full-size thermosyphons
During past two decades, at temperature 240-265°C, resource tests were carried out on 19 thermosyphons of full-scale sizes: 45х4 mm in diameter, 4.92 m in length. The thermosyphons were prepared with varying preliminary surface treatment methods, composition of the aqueous solution to be poured into...
Main Authors: | Balunov Boris, Egorov Mikle |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_05009.pdf |
Similar Items
-
Fluid mechanics tests of separator-reheater turbines
by: Egorov Mikle, et al.
Published: (2018-01-01) -
<b>Modeling and experimental tests of a copper thermosyphon
by: Paulo Henrique Dias dos Santos, et al.
Published: (2017-02-01) -
Evaluation on cooling performance and reliability of low-height aluminum thermosyphon in high-temperature environment
by: Takayuki FUJIMOTO, et al.
Published: (2019-06-01) -
Two phase thermosyphon for high heat flux cooling application
by: Lee, Kai An.
Published: (2009) -
Thermosyphon cooling system for high heat flux electronic components
by: Koh, Zheng Jie.
Published: (2010)