Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol

Aerosol source apportionment remains a critical challenge for understanding the transport and aging of aerosols, as well as for developing successful air pollution mitigation strategies. The contributions of fossil and non-fossil sources to organic carbon (OC) and elemental carbon (EC) in carbonaceo...

Full description

Bibliographic Details
Main Authors: G. O. Mouteva, S. M. Fahrni, G. M. Santos, J. T. Randerson, Y.-L. Zhang, S. Szidat, C. I. Czimczik
Format: Article
Language:English
Published: Copernicus Publications 2015-09-01
Series:Atmospheric Measurement Techniques
Online Access:http://www.atmos-meas-tech.net/8/3729/2015/amt-8-3729-2015.pdf
_version_ 1819211753138946048
author G. O. Mouteva
S. M. Fahrni
G. M. Santos
J. T. Randerson
Y.-L. Zhang
S. Szidat
C. I. Czimczik
author_facet G. O. Mouteva
S. M. Fahrni
G. M. Santos
J. T. Randerson
Y.-L. Zhang
S. Szidat
C. I. Czimczik
author_sort G. O. Mouteva
collection DOAJ
description Aerosol source apportionment remains a critical challenge for understanding the transport and aging of aerosols, as well as for developing successful air pollution mitigation strategies. The contributions of fossil and non-fossil sources to organic carbon (OC) and elemental carbon (EC) in carbonaceous aerosols can be quantified by measuring the radiocarbon (<sup>14</sup>C) content of each carbon fraction. However, the use of <sup>14</sup>C in studying OC and EC has been limited by technical challenges related to the physical separation of the two fractions and small sample sizes. There is no common procedure for OC/EC <sup>14</sup>C analysis, and uncertainty studies have largely focused on the precision of yields. Here, we quantified the uncertainty in <sup>14</sup>C measurement of aerosols associated with the isolation and analysis of each carbon fraction with the Swiss_4S thermal–optical analysis (TOA) protocol. We used an OC/EC analyzer (Sunset Laboratory Inc., OR, USA) coupled to a vacuum line to separate the two components. Each fraction was thermally desorbed and converted to carbon dioxide (CO<sub>2</sub>) in pure oxygen (O<sub>2</sub>). On average, 91 % of the evolving CO<sub>2</sub> was then cryogenically trapped on the vacuum line, reduced to filamentous graphite, and measured for its <sup>14</sup>C content via accelerator mass spectrometry (AMS). To test the accuracy of our setup, we quantified the total amount of extraneous carbon introduced during the TOA sample processing and graphitization as the sum of modern and fossil (<sup>14</sup>C-depleted) carbon introduced during the analysis of fossil reference materials (adipic acid for OC and coal for EC) and contemporary standards (oxalic acid for OC and rice char for EC) as a function of sample size. We further tested our methodology by analyzing five ambient airborne particulate matter (PM<sub>2.5</sub>) samples with a range of OC and EC concentrations and <sup>14</sup>C contents in an interlaboratory comparison. The total modern and fossil carbon blanks of our setup were 0.8 ± 0.4 and 0.67 ± 0.34 μg C, respectively, based on multiple measurements of ultra-small samples. The extraction procedure (Swiss_4S protocol and cryo-trapping only) contributed 0.37 ± 0.18 μg of modern carbon and 0.13 ± 0.07 μg of fossil carbon to the total blank of our system, with consistent estimates obtained for the two laboratories. There was no difference in the background correction between the OC and EC fractions. Our setup allowed us to efficiently isolate and trap each carbon fraction with the Swiss_4S protocol and to perform <sup>14</sup>C analysis of ultra-small OC and EC samples with high accuracy and low <sup>14</sup>C blanks.
first_indexed 2024-12-23T06:32:05Z
format Article
id doaj.art-5f108808cf1e4a258ed54b3c67cdd428
institution Directory Open Access Journal
issn 1867-1381
1867-8548
language English
last_indexed 2024-12-23T06:32:05Z
publishDate 2015-09-01
publisher Copernicus Publications
record_format Article
series Atmospheric Measurement Techniques
spelling doaj.art-5f108808cf1e4a258ed54b3c67cdd4282022-12-21T17:56:53ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482015-09-01893729374310.5194/amt-8-3729-2015Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocolG. O. Mouteva0S. M. Fahrni1G. M. Santos2J. T. Randerson3Y.-L. Zhang4S. Szidat5C. I. Czimczik6Earth System Science, University of California, Irvine, CA, USAEarth System Science, University of California, Irvine, CA, USAEarth System Science, University of California, Irvine, CA, USAEarth System Science, University of California, Irvine, CA, USADepartment of Chemistry and Biochemistry & Oeschger Centre for Climate Change Research, University of Bern, Bern, SwitzerlandDepartment of Chemistry and Biochemistry & Oeschger Centre for Climate Change Research, University of Bern, Bern, SwitzerlandEarth System Science, University of California, Irvine, CA, USAAerosol source apportionment remains a critical challenge for understanding the transport and aging of aerosols, as well as for developing successful air pollution mitigation strategies. The contributions of fossil and non-fossil sources to organic carbon (OC) and elemental carbon (EC) in carbonaceous aerosols can be quantified by measuring the radiocarbon (<sup>14</sup>C) content of each carbon fraction. However, the use of <sup>14</sup>C in studying OC and EC has been limited by technical challenges related to the physical separation of the two fractions and small sample sizes. There is no common procedure for OC/EC <sup>14</sup>C analysis, and uncertainty studies have largely focused on the precision of yields. Here, we quantified the uncertainty in <sup>14</sup>C measurement of aerosols associated with the isolation and analysis of each carbon fraction with the Swiss_4S thermal–optical analysis (TOA) protocol. We used an OC/EC analyzer (Sunset Laboratory Inc., OR, USA) coupled to a vacuum line to separate the two components. Each fraction was thermally desorbed and converted to carbon dioxide (CO<sub>2</sub>) in pure oxygen (O<sub>2</sub>). On average, 91 % of the evolving CO<sub>2</sub> was then cryogenically trapped on the vacuum line, reduced to filamentous graphite, and measured for its <sup>14</sup>C content via accelerator mass spectrometry (AMS). To test the accuracy of our setup, we quantified the total amount of extraneous carbon introduced during the TOA sample processing and graphitization as the sum of modern and fossil (<sup>14</sup>C-depleted) carbon introduced during the analysis of fossil reference materials (adipic acid for OC and coal for EC) and contemporary standards (oxalic acid for OC and rice char for EC) as a function of sample size. We further tested our methodology by analyzing five ambient airborne particulate matter (PM<sub>2.5</sub>) samples with a range of OC and EC concentrations and <sup>14</sup>C contents in an interlaboratory comparison. The total modern and fossil carbon blanks of our setup were 0.8 ± 0.4 and 0.67 ± 0.34 μg C, respectively, based on multiple measurements of ultra-small samples. The extraction procedure (Swiss_4S protocol and cryo-trapping only) contributed 0.37 ± 0.18 μg of modern carbon and 0.13 ± 0.07 μg of fossil carbon to the total blank of our system, with consistent estimates obtained for the two laboratories. There was no difference in the background correction between the OC and EC fractions. Our setup allowed us to efficiently isolate and trap each carbon fraction with the Swiss_4S protocol and to perform <sup>14</sup>C analysis of ultra-small OC and EC samples with high accuracy and low <sup>14</sup>C blanks.http://www.atmos-meas-tech.net/8/3729/2015/amt-8-3729-2015.pdf
spellingShingle G. O. Mouteva
S. M. Fahrni
G. M. Santos
J. T. Randerson
Y.-L. Zhang
S. Szidat
C. I. Czimczik
Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol
Atmospheric Measurement Techniques
title Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol
title_full Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol
title_fullStr Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol
title_full_unstemmed Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol
title_short Accuracy and precision of <sup>14</sup>C-based source apportionment of organic and elemental carbon in aerosols using the Swiss_4S protocol
title_sort accuracy and precision of sup 14 sup c based source apportionment of organic and elemental carbon in aerosols using the swiss 4s protocol
url http://www.atmos-meas-tech.net/8/3729/2015/amt-8-3729-2015.pdf
work_keys_str_mv AT gomouteva accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol
AT smfahrni accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol
AT gmsantos accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol
AT jtranderson accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol
AT ylzhang accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol
AT sszidat accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol
AT ciczimczik accuracyandprecisionofsup14supcbasedsourceapportionmentoforganicandelementalcarboninaerosolsusingtheswiss4sprotocol