Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.

The levels of indoor air microbial load in hospitals are very crucial to the health of patients and health care workers and are to be regularly monitored and maintained at an acceptable level. However, this problem remains overlooked, particularly in developing countries including Ethiopia. A hospit...

Full description

Bibliographic Details
Main Authors: Gebre Kayta, Aseer Manilal, Dagimawie Tadesse, Munira Siraj
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0271022
_version_ 1811223238881050624
author Gebre Kayta
Aseer Manilal
Dagimawie Tadesse
Munira Siraj
author_facet Gebre Kayta
Aseer Manilal
Dagimawie Tadesse
Munira Siraj
author_sort Gebre Kayta
collection DOAJ
description The levels of indoor air microbial load in hospitals are very crucial to the health of patients and health care workers and are to be regularly monitored and maintained at an acceptable level. However, this problem remains overlooked, particularly in developing countries including Ethiopia. A hospital-based cross-sectional study is designed to determine the indoor air microbial load (settle plate technique), microbial isolates (standard microbiological techniques), bacterial susceptibility profiles (Kirby-Bauer disk diffusion technique), and associated factors, in different wards of the title Hospital, southern Ethiopia. An observational checklist was used to collect relevant information related to the associated factors; descriptive and inferential statistics were applied using Statistical Package for Social Sciences (SPSS); p-values ≤ 0.05 in the multivariable analysis were considered statistically significant. The total average bacterial and fungal load of the selected wards was 1914±1081.4 Colony Forming Units (CFU)/m3 (95% CI: 1718.5-2109.48 CFU/m3) and 1533.7±858.8 CFU/m3 (95% CI: 1378.5-1688CFU/m3) respectively. The highest mean bacterial (1914±1081.4 CFU/m3) and fungal (1533.7±858.8 CFU/m3) loads were found in the male surgical and female medical wards respectively. A total of 229 bacterial and 139 fungal isolates were obtained; Gram-positive bacteria were the predominant type, 130 (56.7%), particularly the isolates of Staphylococcus aureus, 46 (20.1%). The predominant fungal isolates were Aspergillus sp., 53(38%). Percentages of multidrug-resistant (MDR), extended-spectrum beta-lactamase (ESBL), and carbapenemase producers respectively were 48.5, 26.5, and 25%. High room crowd index [p = 0.003; Adjusted Odds Ratio (AOR) 12.5 (Confidence Interval (CI) 95%: 2.42-65)], presence of damp/wet materials [p = 0.025; AOR 7 (CI 95%: 1.3-37.4)], intense room traffic [p = 0.004; AOR 9.6 (CI 95%: 1.2-79.3)], inappropriate storage of food and drugs [p = 0.008; AOR 7.5 (CI 95%: 1.7-32)], and unclean environment [p = 0.03; AOR 5.8 (CI 95%: 1.2-28)] showed statistical significance concerning the indoor air microbial loads; most of the wards in Arba Minch General Hospital (AMGH) stand high and not in an acceptable level as per the WHO and the European Commission standards on indoor air microbial load. Periodic air surveillance and infection prevention control programs are required to reduce the transmission of these microbes to inpatients, visitors, and health care workers.
first_indexed 2024-04-12T08:28:39Z
format Article
id doaj.art-5f501773481f466bb04973bf5481bb50
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-12T08:28:39Z
publishDate 2022-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-5f501773481f466bb04973bf5481bb502022-12-22T03:40:16ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01177e027102210.1371/journal.pone.0271022Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.Gebre KaytaAseer ManilalDagimawie TadesseMunira SirajThe levels of indoor air microbial load in hospitals are very crucial to the health of patients and health care workers and are to be regularly monitored and maintained at an acceptable level. However, this problem remains overlooked, particularly in developing countries including Ethiopia. A hospital-based cross-sectional study is designed to determine the indoor air microbial load (settle plate technique), microbial isolates (standard microbiological techniques), bacterial susceptibility profiles (Kirby-Bauer disk diffusion technique), and associated factors, in different wards of the title Hospital, southern Ethiopia. An observational checklist was used to collect relevant information related to the associated factors; descriptive and inferential statistics were applied using Statistical Package for Social Sciences (SPSS); p-values ≤ 0.05 in the multivariable analysis were considered statistically significant. The total average bacterial and fungal load of the selected wards was 1914±1081.4 Colony Forming Units (CFU)/m3 (95% CI: 1718.5-2109.48 CFU/m3) and 1533.7±858.8 CFU/m3 (95% CI: 1378.5-1688CFU/m3) respectively. The highest mean bacterial (1914±1081.4 CFU/m3) and fungal (1533.7±858.8 CFU/m3) loads were found in the male surgical and female medical wards respectively. A total of 229 bacterial and 139 fungal isolates were obtained; Gram-positive bacteria were the predominant type, 130 (56.7%), particularly the isolates of Staphylococcus aureus, 46 (20.1%). The predominant fungal isolates were Aspergillus sp., 53(38%). Percentages of multidrug-resistant (MDR), extended-spectrum beta-lactamase (ESBL), and carbapenemase producers respectively were 48.5, 26.5, and 25%. High room crowd index [p = 0.003; Adjusted Odds Ratio (AOR) 12.5 (Confidence Interval (CI) 95%: 2.42-65)], presence of damp/wet materials [p = 0.025; AOR 7 (CI 95%: 1.3-37.4)], intense room traffic [p = 0.004; AOR 9.6 (CI 95%: 1.2-79.3)], inappropriate storage of food and drugs [p = 0.008; AOR 7.5 (CI 95%: 1.7-32)], and unclean environment [p = 0.03; AOR 5.8 (CI 95%: 1.2-28)] showed statistical significance concerning the indoor air microbial loads; most of the wards in Arba Minch General Hospital (AMGH) stand high and not in an acceptable level as per the WHO and the European Commission standards on indoor air microbial load. Periodic air surveillance and infection prevention control programs are required to reduce the transmission of these microbes to inpatients, visitors, and health care workers.https://doi.org/10.1371/journal.pone.0271022
spellingShingle Gebre Kayta
Aseer Manilal
Dagimawie Tadesse
Munira Siraj
Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.
PLoS ONE
title Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.
title_full Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.
title_fullStr Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.
title_full_unstemmed Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.
title_short Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia.
title_sort indoor air microbial load antibiotic susceptibility profiles of bacteria and associated factors in different wards of arba minch general hospital southern ethiopia
url https://doi.org/10.1371/journal.pone.0271022
work_keys_str_mv AT gebrekayta indoorairmicrobialloadantibioticsusceptibilityprofilesofbacteriaandassociatedfactorsindifferentwardsofarbaminchgeneralhospitalsouthernethiopia
AT aseermanilal indoorairmicrobialloadantibioticsusceptibilityprofilesofbacteriaandassociatedfactorsindifferentwardsofarbaminchgeneralhospitalsouthernethiopia
AT dagimawietadesse indoorairmicrobialloadantibioticsusceptibilityprofilesofbacteriaandassociatedfactorsindifferentwardsofarbaminchgeneralhospitalsouthernethiopia
AT munirasiraj indoorairmicrobialloadantibioticsusceptibilityprofilesofbacteriaandassociatedfactorsindifferentwardsofarbaminchgeneralhospitalsouthernethiopia