Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch

Background: Accurate assessment of intra- as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA). The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dua...

Full description

Bibliographic Details
Main Authors: Hai-Ou Li, Xi-Ming Wang, Pei Nie, Xiao-Peng Ji, Zhao-Ping Cheng, Jiu-Hong Chen, Zhuo-Dong Xu
Format: Article
Language:English
Published: Wolters Kluwer 2015-01-01
Series:Chinese Medical Journal
Subjects:
Online Access:http://www.cmj.org/article.asp?issn=0366-6999;year=2015;volume=128;issue=9;spage=1184;epage=1189;aulast=Li
_version_ 1819264116695498752
author Hai-Ou Li
Xi-Ming Wang
Pei Nie
Xiao-Peng Ji
Zhao-Ping Cheng
Jiu-Hong Chen
Zhuo-Dong Xu
author_facet Hai-Ou Li
Xi-Ming Wang
Pei Nie
Xiao-Peng Ji
Zhao-Ping Cheng
Jiu-Hong Chen
Zhuo-Dong Xu
author_sort Hai-Ou Li
collection DOAJ
description Background: Accurate assessment of intra- as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA). The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA. Methods: Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE). Surgery was performed on all the patients. A five-point scale was used to assess image quality. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. A nonparametric Chi-square test was used for comparative analysis. P <0.05 was considered as a significant difference. The mean effective radiation dose (ED) was calculated. Results: Diagnostic DSCT images were obtained for all the patients. Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings. The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P > 0.05), and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05), respectively. The mean score of image quality was 3.77 ± 0.83. The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv). Conclusions: In infants and children with IAA, prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.
first_indexed 2024-12-23T20:24:22Z
format Article
id doaj.art-5f8cf412d3e248b59da1528ab448ae5c
institution Directory Open Access Journal
issn 0366-6999
language English
last_indexed 2024-12-23T20:24:22Z
publishDate 2015-01-01
publisher Wolters Kluwer
record_format Article
series Chinese Medical Journal
spelling doaj.art-5f8cf412d3e248b59da1528ab448ae5c2022-12-21T17:32:26ZengWolters KluwerChinese Medical Journal0366-69992015-01-0112891184118910.4103/0366-6999.156109Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic ArchHai-Ou LiXi-Ming WangPei NieXiao-Peng JiZhao-Ping ChengJiu-Hong ChenZhuo-Dong XuBackground: Accurate assessment of intra- as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA). The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA. Methods: Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE). Surgery was performed on all the patients. A five-point scale was used to assess image quality. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. A nonparametric Chi-square test was used for comparative analysis. P <0.05 was considered as a significant difference. The mean effective radiation dose (ED) was calculated. Results: Diagnostic DSCT images were obtained for all the patients. Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings. The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P > 0.05), and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05), respectively. The mean score of image quality was 3.77 ± 0.83. The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv). Conclusions: In infants and children with IAA, prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.http://www.cmj.org/article.asp?issn=0366-6999;year=2015;volume=128;issue=9;spage=1184;epage=1189;aulast=LiDual-source Computed Tomography; Image Quality; Interrupted Aortic Arch; Prospective ECG-triggered; Radiation Dose
spellingShingle Hai-Ou Li
Xi-Ming Wang
Pei Nie
Xiao-Peng Ji
Zhao-Ping Cheng
Jiu-Hong Chen
Zhuo-Dong Xu
Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
Chinese Medical Journal
Dual-source Computed Tomography; Image Quality; Interrupted Aortic Arch; Prospective ECG-triggered; Radiation Dose
title Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
title_full Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
title_fullStr Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
title_full_unstemmed Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
title_short Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
title_sort diagnostic value of prospective electrocardiogram triggered dual source computed tomography angiography for infants and children with interrupted aortic arch
topic Dual-source Computed Tomography; Image Quality; Interrupted Aortic Arch; Prospective ECG-triggered; Radiation Dose
url http://www.cmj.org/article.asp?issn=0366-6999;year=2015;volume=128;issue=9;spage=1184;epage=1189;aulast=Li
work_keys_str_mv AT haiouli diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch
AT ximingwang diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch
AT peinie diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch
AT xiaopengji diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch
AT zhaopingcheng diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch
AT jiuhongchen diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch
AT zhuodongxu diagnosticvalueofprospectiveelectrocardiogramtriggereddualsourcecomputedtomographyangiographyforinfantsandchildrenwithinterruptedaorticarch