Individualised flow-controlled ventilation reduces applied mechanical power and improves ventilation efficiency in a porcine intra-abdominal hypertension model
Abstract Background Aim of this study was to evaluate feasibility and effects of individualised flow-controlled ventilation (FCV), based on compliance guided pressure settings, compared to standard of pressure-controlled ventilation (PCV) in a porcine intra-abdominal hypertension (IAH) model. The pr...
Main Authors: | Julia Abram, Patrick Spraider, Julian Wagner, Gabriel Putzer, Manuela Ranalter, Sarah Rinner, Andrea Katharina Lindner, Bernhard Glodny, Tobias Hell, Tom Barnes, Dietmar Enk, Judith Martini |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2024-03-01
|
Series: | Intensive Care Medicine Experimental |
Subjects: | |
Online Access: | https://doi.org/10.1186/s40635-024-00608-9 |
Similar Items
-
Comparison of two ventilation modes in post-cardiac surgical patients
by: Aloka Samantaray, et al.
Published: (2011-01-01) -
Evaluation of the Effect of Pressure-Controlled Ventilation-Volume Guaranteed Mode vs. Volume-Controlled Ventilation Mode on Atelectasis in Patients Undergoing Laparoscopic Surgery: A Randomized Controlled Clinical Trial
by: Ayse Zeynep Turan Civraz, et al.
Published: (2023-10-01) -
Commentary: Flow-controlled ventilation maintains gas exchange and lung aeration in a pediatric model of healthy and injured lungs: a randomized cross-over experimental study
by: Dietmar Enk, et al.
Published: (2023-06-01) -
Comparison between volume-controlled ventilation and pressure-controlled volume-guaranteed ventilation in postoperative lung atelectasis using lung ultrasound following upper abdominal laparotomies: a prospective randomized study
by: Bahaa El-din Ewees Hassan, et al.
Published: (2020-07-01) -
Ventilators and Ventilatory Modalities
by: Martino Pavone, et al.
Published: (2020-09-01)