Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration

Modern cities are densely populated spaces and number of people living in cities is increasing rapidly by years. The air monitoring stations exist in most of the cities to monitor air pollution. However, their number is insufficient having in mind the high cost of stations, as well as annual calibra...

Full description

Bibliographic Details
Main Authors: Dejan D. Drajic, Nenad R. Gligoric
Format: Article
Language:English
Published: Kaunas University of Technology 2020-04-01
Series:Elektronika ir Elektrotechnika
Subjects:
Online Access:http://eejournal.ktu.lt/index.php/elt/article/view/25734
_version_ 1819183176306655232
author Dejan D. Drajic
Nenad R. Gligoric
author_facet Dejan D. Drajic
Nenad R. Gligoric
author_sort Dejan D. Drajic
collection DOAJ
description Modern cities are densely populated spaces and number of people living in cities is increasing rapidly by years. The air monitoring stations exist in most of the cities to monitor air pollution. However, their number is insufficient having in mind the high cost of stations, as well as annual calibration cost. The potential solution is to use low-cost off-the-shelf sensors to monitor related air quality parameters, but they are not reliable due to the low accuracy, calibration issues, and short life cycle. In this paper, the methodology is proposed for calibration off-the-shelf air quality sensors using statistical algorithms and offset values from the official public measurement stations. The possibilities are analysed to improve the reliability of low-cost sensors by processing the obtained raw data. Special attention is devoted to the detection and elimination of short intervals when the raw results have the extraordinary high value-peaks and to the corresponding interpolation of these data. New algorithm for “peaks” detection and elimination is proposed and evaluated. Common Air Quality Index (CAQI) is calculated and evaluated in comparison with public monitoring station. It is shown that low-cost sensors could be used with high reliability as a complementary network to public monitoring stations.
first_indexed 2024-12-22T22:57:52Z
format Article
id doaj.art-6010751737b645938541522fcd29b0d8
institution Directory Open Access Journal
issn 1392-1215
2029-5731
language English
last_indexed 2024-12-22T22:57:52Z
publishDate 2020-04-01
publisher Kaunas University of Technology
record_format Article
series Elektronika ir Elektrotechnika
spelling doaj.art-6010751737b645938541522fcd29b0d82022-12-21T18:09:46ZengKaunas University of TechnologyElektronika ir Elektrotechnika1392-12152029-57312020-04-01262324110.5755/j01.eie.26.2.2573425734Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical CalibrationDejan D. Drajic0Nenad R. GligoricSenior researcherModern cities are densely populated spaces and number of people living in cities is increasing rapidly by years. The air monitoring stations exist in most of the cities to monitor air pollution. However, their number is insufficient having in mind the high cost of stations, as well as annual calibration cost. The potential solution is to use low-cost off-the-shelf sensors to monitor related air quality parameters, but they are not reliable due to the low accuracy, calibration issues, and short life cycle. In this paper, the methodology is proposed for calibration off-the-shelf air quality sensors using statistical algorithms and offset values from the official public measurement stations. The possibilities are analysed to improve the reliability of low-cost sensors by processing the obtained raw data. Special attention is devoted to the detection and elimination of short intervals when the raw results have the extraordinary high value-peaks and to the corresponding interpolation of these data. New algorithm for “peaks” detection and elimination is proposed and evaluated. Common Air Quality Index (CAQI) is calculated and evaluated in comparison with public monitoring station. It is shown that low-cost sensors could be used with high reliability as a complementary network to public monitoring stations.http://eejournal.ktu.lt/index.php/elt/article/view/25734air pollutioncaqi calculationlow-cost sensorspeaks elimination
spellingShingle Dejan D. Drajic
Nenad R. Gligoric
Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
Elektronika ir Elektrotechnika
air pollution
caqi calculation
low-cost sensors
peaks elimination
title Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
title_full Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
title_fullStr Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
title_full_unstemmed Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
title_short Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
title_sort reliable low cost air quality monitoring using off the shelf sensors and statistical calibration
topic air pollution
caqi calculation
low-cost sensors
peaks elimination
url http://eejournal.ktu.lt/index.php/elt/article/view/25734
work_keys_str_mv AT dejanddrajic reliablelowcostairqualitymonitoringusingofftheshelfsensorsandstatisticalcalibration
AT nenadrgligoric reliablelowcostairqualitymonitoringusingofftheshelfsensorsandstatisticalcalibration