A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION

Topology optimisation is a prominent method to improve the performance of any systems by optimising geometrical factors to save materials without compromising the system functionality. Currently, there is limited published data discussing the topologically optimised dental implants that makes the m...

Full description

Bibliographic Details
Main Authors: Muhammad Ikman Ishak, Ruslizam Daud, Bakri Bakar, Siti Noor Fazliah Mohd Noor
Format: Article
Language:English
Published: IIUM Press, International Islamic University Malaysia 2023-07-01
Series:International Islamic University Malaysia Engineering Journal
Subjects:
Online Access:https://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/2695
_version_ 1797786914971975680
author Muhammad Ikman Ishak
Ruslizam Daud
Bakri Bakar
Siti Noor Fazliah Mohd Noor
author_facet Muhammad Ikman Ishak
Ruslizam Daud
Bakri Bakar
Siti Noor Fazliah Mohd Noor
author_sort Muhammad Ikman Ishak
collection DOAJ
description Topology optimisation is a prominent method to improve the performance of any systems by optimising geometrical factors to save materials without compromising the system functionality. Currently, there is limited published data discussing the topologically optimised dental implants that makes the matter still unclear. This study aimed to evaluate the mechanical and fatigue behaviours of regular and topologically optimised dental implant designs using 3-D FEA. Geometrical models were developed in accordance with ISO 14801 using SolidWorks 2020 before being analysed in ANSYS 18.1. The new implant design was created by topology optimisation analysis. The material properties of all parts were assumed to be isotropic, linearly elastic, and homogenous. Nine different compressive load values ranging from 100 to 500 N were applied on the loading structure as separated cases. The vertical and bottom surfaces of the holder were fully constrained. The results showed that the topologically optimised implant recorded about 12.3% lower implant stress than the regular implant. Both implant designs revealed a comparable displacement result with a percentage difference of only 2.3%. The optimised design was also found to produce longer fatigue life and approximately 12.3% higher safety factor compared to the regular design. The increase in the compressive load value has increased the stress and deformation, whilst decreased the fatigue life and safety factor in both designs. Although it was estimated that the volume of the new implant could be reduced to about 24% of the traditional one, the implant functionality may still be retained or even be improved. ABSTRAK: Pengoptimuman topologi adalah kaedah utama bagi meningkatkan prestasi mana-mana sistem dengan mengoptimumkan faktor geometri bagi menjimatkan bahan tanpa menjejaskan fungsi utama sistem. Dewasa ini, terdapat kurang data diterbitkan berbincang mengenai implan gigi yang dioptimumkan secara topologi yang menjadikan perkara ini masih tidak jelas. Kajian ini bertujuan bagi menilai perlakuan mekanikal dan kelesuan bagi reka bentuk implant gigi biasa dan yang dioptimumkan secara topologi menggunakan 3-D FEA. Model geometri telah dibangunkan mengikut ISO 14801 menggunakan SolidWorks 2020 sebelum dianalisis dalam ANSYS 18.1.  Reka bentuk implan baharu telah dibuat melalui analisis pengoptimuman topologi. Sifat pada semua bahagian bahan diandaikan sebagai isotropik, keanjalan linear, dan homogen. Sembilan nilai beban mampatan berbeza antara 100 hingga 500 N telah dikenakan pada struktur pembebanan sebagai kes berasingan. Permukaan menegak dan bawah pemegang dikekang sepenuhnya. Keputusan menunjukkan bahawa implan yang dioptimumkan secara topologi merekodkan tegasan implan 12.3% lebih rendah daripada implan biasa. Kedua-dua reka bentuk implan menunjukkan hasil anjakan yang setanding dengan perbezaan peratusan hanyalah 2.3%. Reka bentuk yang dioptimumkan juga didapati menghasilkan hayat kelesuan yang lebih lama dan kira-kira 12.3% faktor keselamatan yang lebih tinggi berbanding reka bentuk biasa. Peningkatan dalam nilai beban mampatan telah meningkatkan tegasan dan perubahan bentuk, sementara mengurangkan hayat kelesuan dan faktor keselamatan dalam kedua-dua reka bentuk. Walaupun dianggarkan bahawa isipadu implan baru boleh dikurangkan kira-kira 24% daripada implan tradisional, fungsi implan masih boleh dikekalkan atau dipertingkatkan.
first_indexed 2024-03-13T01:15:31Z
format Article
id doaj.art-6017495616ad41fca14b12d169977812
institution Directory Open Access Journal
issn 1511-788X
2289-7860
language English
last_indexed 2024-03-13T01:15:31Z
publishDate 2023-07-01
publisher IIUM Press, International Islamic University Malaysia
record_format Article
series International Islamic University Malaysia Engineering Journal
spelling doaj.art-6017495616ad41fca14b12d1699778122023-07-05T10:59:51ZengIIUM Press, International Islamic University MalaysiaInternational Islamic University Malaysia Engineering Journal1511-788X2289-78602023-07-0124210.31436/iiumej.v24i2.2695A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATIONMuhammad Ikman Ishak0Ruslizam Daud1Bakri Bakar2Siti Noor Fazliah Mohd Noor3Universiti Malaysia Perlis Universiti Malaysia Perlis Universiti Malaysia PerlisUniversiti Sains Malaysia Topology optimisation is a prominent method to improve the performance of any systems by optimising geometrical factors to save materials without compromising the system functionality. Currently, there is limited published data discussing the topologically optimised dental implants that makes the matter still unclear. This study aimed to evaluate the mechanical and fatigue behaviours of regular and topologically optimised dental implant designs using 3-D FEA. Geometrical models were developed in accordance with ISO 14801 using SolidWorks 2020 before being analysed in ANSYS 18.1. The new implant design was created by topology optimisation analysis. The material properties of all parts were assumed to be isotropic, linearly elastic, and homogenous. Nine different compressive load values ranging from 100 to 500 N were applied on the loading structure as separated cases. The vertical and bottom surfaces of the holder were fully constrained. The results showed that the topologically optimised implant recorded about 12.3% lower implant stress than the regular implant. Both implant designs revealed a comparable displacement result with a percentage difference of only 2.3%. The optimised design was also found to produce longer fatigue life and approximately 12.3% higher safety factor compared to the regular design. The increase in the compressive load value has increased the stress and deformation, whilst decreased the fatigue life and safety factor in both designs. Although it was estimated that the volume of the new implant could be reduced to about 24% of the traditional one, the implant functionality may still be retained or even be improved. ABSTRAK: Pengoptimuman topologi adalah kaedah utama bagi meningkatkan prestasi mana-mana sistem dengan mengoptimumkan faktor geometri bagi menjimatkan bahan tanpa menjejaskan fungsi utama sistem. Dewasa ini, terdapat kurang data diterbitkan berbincang mengenai implan gigi yang dioptimumkan secara topologi yang menjadikan perkara ini masih tidak jelas. Kajian ini bertujuan bagi menilai perlakuan mekanikal dan kelesuan bagi reka bentuk implant gigi biasa dan yang dioptimumkan secara topologi menggunakan 3-D FEA. Model geometri telah dibangunkan mengikut ISO 14801 menggunakan SolidWorks 2020 sebelum dianalisis dalam ANSYS 18.1.  Reka bentuk implan baharu telah dibuat melalui analisis pengoptimuman topologi. Sifat pada semua bahagian bahan diandaikan sebagai isotropik, keanjalan linear, dan homogen. Sembilan nilai beban mampatan berbeza antara 100 hingga 500 N telah dikenakan pada struktur pembebanan sebagai kes berasingan. Permukaan menegak dan bawah pemegang dikekang sepenuhnya. Keputusan menunjukkan bahawa implan yang dioptimumkan secara topologi merekodkan tegasan implan 12.3% lebih rendah daripada implan biasa. Kedua-dua reka bentuk implan menunjukkan hasil anjakan yang setanding dengan perbezaan peratusan hanyalah 2.3%. Reka bentuk yang dioptimumkan juga didapati menghasilkan hayat kelesuan yang lebih lama dan kira-kira 12.3% faktor keselamatan yang lebih tinggi berbanding reka bentuk biasa. Peningkatan dalam nilai beban mampatan telah meningkatkan tegasan dan perubahan bentuk, sementara mengurangkan hayat kelesuan dan faktor keselamatan dalam kedua-dua reka bentuk. Walaupun dianggarkan bahawa isipadu implan baru boleh dikurangkan kira-kira 24% daripada implan tradisional, fungsi implan masih boleh dikekalkan atau dipertingkatkan. https://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/2695DeformationDental implantFatigueFinite element analysisTopology optimisation
spellingShingle Muhammad Ikman Ishak
Ruslizam Daud
Bakri Bakar
Siti Noor Fazliah Mohd Noor
A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
International Islamic University Malaysia Engineering Journal
Deformation
Dental implant
Fatigue
Finite element analysis
Topology optimisation
title A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
title_full A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
title_fullStr A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
title_full_unstemmed A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
title_short A COMPARATIVE FINITE ELEMENT ANALYSIS OF REGULAR AND TOPOLOGICALLY OPTIMISED DENTAL IMPLANTS FOR MECHANICAL AND FATIGUE RESPONSES EVALUATION
title_sort comparative finite element analysis of regular and topologically optimised dental implants for mechanical and fatigue responses evaluation
topic Deformation
Dental implant
Fatigue
Finite element analysis
Topology optimisation
url https://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/2695
work_keys_str_mv AT muhammadikmanishak acomparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT ruslizamdaud acomparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT bakribakar acomparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT sitinoorfazliahmohdnoor acomparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT muhammadikmanishak comparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT ruslizamdaud comparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT bakribakar comparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation
AT sitinoorfazliahmohdnoor comparativefiniteelementanalysisofregularandtopologicallyoptimiseddentalimplantsformechanicalandfatigueresponsesevaluation