Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays

Atraumatic insertions of electrode arrays (EA) into the cochlea aim to preserve natural structures and residual hearing. However, there is a limit as to how smooth and slow a surgeon can insert an EA. As a potential solution, we recently presented a tool (cochlea hydro drive, CHD) that makes use of...

Full description

Bibliographic Details
Main Authors: Zuniga M. Geraldine, Schell Viktor, Cramer Jakob, Lenarz Thomas, Rau Thomas S.
Format: Article
Language:English
Published: De Gruyter 2021-10-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2021-2028
_version_ 1811194215078559744
author Zuniga M. Geraldine
Schell Viktor
Cramer Jakob
Lenarz Thomas
Rau Thomas S.
author_facet Zuniga M. Geraldine
Schell Viktor
Cramer Jakob
Lenarz Thomas
Rau Thomas S.
author_sort Zuniga M. Geraldine
collection DOAJ
description Atraumatic insertions of electrode arrays (EA) into the cochlea aim to preserve natural structures and residual hearing. However, there is a limit as to how smooth and slow a surgeon can insert an EA. As a potential solution, we recently presented a tool (cochlea hydro drive, CHD) that makes use of an infusion pump to prompt and control the desired, continuous and very slow (< 1 mm/s) forward movement for such insertions. The present work further describes the onset, delay and cessation of the hydraulic actuation in response to different start and stop mechanisms, to better understand the safety of its application for cochlear implant surgery. Methods: Our previously designed tool was used to perform insertions of an EA into an artificial scala tympani model. The prototype is designed to hold an EA, which is then actuated by a standard infusion pump programmed to operate at 0.4 mm/ and 0.1 mm/s. A tubing system between the CHD and the pump includes a three-way valve. Ten insertions were operated using the functions of the pump and ten using the valve. Results: From the programmed start to the actual movement, we observed a larger average delay using the pump’s start function (5 s at 0.4 mm/s; 17 s at 0.1 mm/s) vs. opening the valve (< 0.7 s for both velocities). Moreover, the average cessation of movement with the valve closure was almost immediate (0.7 s for both velocities; this corresponds to < 0.1 mm with the slower tested velocity), as opposed to 60- 80 s delay when using the pump’s stop function. Conclusion: The use of a 3-way valve facilitates motion cessation to the high accuracy level required for cochlear implant surgery. These promising findings support future clinical translation of our tool.
first_indexed 2024-04-12T00:22:12Z
format Article
id doaj.art-6037b63518a34d5ca6eb829b34342dc1
institution Directory Open Access Journal
issn 2364-5504
language English
last_indexed 2024-04-12T00:22:12Z
publishDate 2021-10-01
publisher De Gruyter
record_format Article
series Current Directions in Biomedical Engineering
spelling doaj.art-6037b63518a34d5ca6eb829b34342dc12022-12-22T03:55:41ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042021-10-017210911210.1515/cdbme-2021-2028Reliability of start and stop control of hydraulic actuation for the insertion of electrode arraysZuniga M. Geraldine0Schell Viktor1Cramer Jakob2Lenarz Thomas3Rau Thomas S.4Department of Otolaryngology and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, Carl-Neuberg-Strasse 1, 30625Hannover, GermanyDepartment of Otolaryngology and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School,Hannover, GermanyDepartment of Otolaryngology and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School,Hannover, GermanyDepartment of Otolaryngology and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School,Hannover, GermanyDepartment of Otolaryngology and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School,Hannover, GermanyAtraumatic insertions of electrode arrays (EA) into the cochlea aim to preserve natural structures and residual hearing. However, there is a limit as to how smooth and slow a surgeon can insert an EA. As a potential solution, we recently presented a tool (cochlea hydro drive, CHD) that makes use of an infusion pump to prompt and control the desired, continuous and very slow (< 1 mm/s) forward movement for such insertions. The present work further describes the onset, delay and cessation of the hydraulic actuation in response to different start and stop mechanisms, to better understand the safety of its application for cochlear implant surgery. Methods: Our previously designed tool was used to perform insertions of an EA into an artificial scala tympani model. The prototype is designed to hold an EA, which is then actuated by a standard infusion pump programmed to operate at 0.4 mm/ and 0.1 mm/s. A tubing system between the CHD and the pump includes a three-way valve. Ten insertions were operated using the functions of the pump and ten using the valve. Results: From the programmed start to the actual movement, we observed a larger average delay using the pump’s start function (5 s at 0.4 mm/s; 17 s at 0.1 mm/s) vs. opening the valve (< 0.7 s for both velocities). Moreover, the average cessation of movement with the valve closure was almost immediate (0.7 s for both velocities; this corresponds to < 0.1 mm with the slower tested velocity), as opposed to 60- 80 s delay when using the pump’s stop function. Conclusion: The use of a 3-way valve facilitates motion cessation to the high accuracy level required for cochlear implant surgery. These promising findings support future clinical translation of our tool.https://doi.org/10.1515/cdbme-2021-2028cochlear implantautomatedsoft surgery
spellingShingle Zuniga M. Geraldine
Schell Viktor
Cramer Jakob
Lenarz Thomas
Rau Thomas S.
Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
Current Directions in Biomedical Engineering
cochlear implant
automated
soft surgery
title Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
title_full Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
title_fullStr Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
title_full_unstemmed Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
title_short Reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
title_sort reliability of start and stop control of hydraulic actuation for the insertion of electrode arrays
topic cochlear implant
automated
soft surgery
url https://doi.org/10.1515/cdbme-2021-2028
work_keys_str_mv AT zunigamgeraldine reliabilityofstartandstopcontrolofhydraulicactuationfortheinsertionofelectrodearrays
AT schellviktor reliabilityofstartandstopcontrolofhydraulicactuationfortheinsertionofelectrodearrays
AT cramerjakob reliabilityofstartandstopcontrolofhydraulicactuationfortheinsertionofelectrodearrays
AT lenarzthomas reliabilityofstartandstopcontrolofhydraulicactuationfortheinsertionofelectrodearrays
AT rauthomass reliabilityofstartandstopcontrolofhydraulicactuationfortheinsertionofelectrodearrays