Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode

The uneven distribution of the baby incubator temperature can cause the temperature in the baby incubator to be different at each point. The purpose of this study was to analyze the effect of the door closed and opened to the temperature at each point of sensor placement that has been determined. Th...

Full description

Bibliographic Details
Main Authors: Vanda Catur Kirana, Dwi Herry Andayani, Andjar Pudji
Format: Article
Language:English
Published: Jurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes Surabaya 2021-08-01
Series:Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
Subjects:
Online Access:http://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/127
_version_ 1797786635833704448
author Vanda Catur Kirana
Dwi Herry Andayani
Andjar Pudji
author_facet Vanda Catur Kirana
Dwi Herry Andayani
Andjar Pudji
author_sort Vanda Catur Kirana
collection DOAJ
description The uneven distribution of the baby incubator temperature can cause the temperature in the baby incubator to be different at each point. The purpose of this study was to analyze the effect of the door closed and opened to the temperature at each point of sensor placement that has been determined. The study was conducted as an experimental research design. In this experiment, an Incu Analyzer comparison was used as a calibrator unit, a baby skin temperature thermistor sensor, and four LM35 sensors for baby incubator room temperature with one LM35 sensor as a PID control system carried out by trial-and-error method. Based on the results of measurements was made with the design, when the chamber is open, it produces an average error value of T1 4.083%, T2 6.06%, T3 3.78%, T4 4.88%, and T5 1.48%, while when the chamber is closed, it produces an average error value T1 0.75. %, T2 0.88%, T3 1.15%, T4 0.74%, and T5 0.87%. Measurement of skin temperature using a thermometer has an average error value of 1.1%. The results showed that uneven heat transfer, lack of air distribution, different sensor placements at each point, and non-standard chamber sizes were factors that were uneven at each point. Based on the results of the study, it was found that the use of a working system on this device can be implemented to control the temperature of the baby incubator by knowing the temperature distribution at each point
first_indexed 2024-03-13T01:11:42Z
format Article
id doaj.art-6118ee325edc4a7692ed8696b7112e6b
institution Directory Open Access Journal
issn 2656-8624
language English
last_indexed 2024-03-13T01:11:42Z
publishDate 2021-08-01
publisher Jurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes Surabaya
record_format Article
series Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
spelling doaj.art-6118ee325edc4a7692ed8696b7112e6b2023-07-05T22:14:31ZengJurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes SurabayaIndonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics2656-86242021-08-013312112710.35882/ijeeemi.v3i3.6127Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo ModeVanda Catur Kirana0Dwi Herry Andayani1Andjar Pudji2College StudentDepartment of Electromedical Engineering, Poltekkes Kemenkes SurabayaDepartment of Electromedical Engineering, Poltekkes Kemenkes SurabayaThe uneven distribution of the baby incubator temperature can cause the temperature in the baby incubator to be different at each point. The purpose of this study was to analyze the effect of the door closed and opened to the temperature at each point of sensor placement that has been determined. The study was conducted as an experimental research design. In this experiment, an Incu Analyzer comparison was used as a calibrator unit, a baby skin temperature thermistor sensor, and four LM35 sensors for baby incubator room temperature with one LM35 sensor as a PID control system carried out by trial-and-error method. Based on the results of measurements was made with the design, when the chamber is open, it produces an average error value of T1 4.083%, T2 6.06%, T3 3.78%, T4 4.88%, and T5 1.48%, while when the chamber is closed, it produces an average error value T1 0.75. %, T2 0.88%, T3 1.15%, T4 0.74%, and T5 0.87%. Measurement of skin temperature using a thermometer has an average error value of 1.1%. The results showed that uneven heat transfer, lack of air distribution, different sensor placements at each point, and non-standard chamber sizes were factors that were uneven at each point. Based on the results of the study, it was found that the use of a working system on this device can be implemented to control the temperature of the baby incubator by knowing the temperature distribution at each pointhttp://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/127lm35infant incubatr babykangorootemperaturedistribution
spellingShingle Vanda Catur Kirana
Dwi Herry Andayani
Andjar Pudji
Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
lm35
infant incubatr baby
kangoroo
temperature
distribution
title Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode
title_full Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode
title_fullStr Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode
title_full_unstemmed Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode
title_short Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode
title_sort effect of closed and opened the door to temperature on pid based baby incubator with kangaroo mode
topic lm35
infant incubatr baby
kangoroo
temperature
distribution
url http://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/127
work_keys_str_mv AT vandacaturkirana effectofclosedandopenedthedoortotemperatureonpidbasedbabyincubatorwithkangaroomode
AT dwiherryandayani effectofclosedandopenedthedoortotemperatureonpidbasedbabyincubatorwithkangaroomode
AT andjarpudji effectofclosedandopenedthedoortotemperatureonpidbasedbabyincubatorwithkangaroomode