Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients?
Cássia da Luz Goulart,1 Ramona Cabiddu,2 Paloma de Borba Schneiders,1 Elisabete Antunes San Martin,1 Renata Trimer,3 Audrey Borghi-Silva,2 Andréa Lúcia Gonçalves da Silva4,5 1Course of Physiotherapy, University of Santa Cruz do Sul, Rio Grande do...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2017-03-01
|
Series: | International Journal of COPD |
Subjects: | |
Online Access: | https://www.dovepress.com/is-cardiac-autonomic-modulation-during-upper-limb-isometric-contractio-peer-reviewed-article-COPD |
_version_ | 1818558499957768192 |
---|---|
author | Goulart CL Cabiddu R Schneiders PB Antunes San Martin E Trimer R Borghi-Silva A da Silva ALG |
author_facet | Goulart CL Cabiddu R Schneiders PB Antunes San Martin E Trimer R Borghi-Silva A da Silva ALG |
author_sort | Goulart CL |
collection | DOAJ |
description | Cássia da Luz Goulart,1 Ramona Cabiddu,2 Paloma de Borba Schneiders,1 Elisabete Antunes San Martin,1 Renata Trimer,3 Audrey Borghi-Silva,2 Andréa Lúcia Gonçalves da Silva4,5 1Course of Physiotherapy, University of Santa Cruz do Sul, Rio Grande do Sul, Brazil; 2Cardiopulmonary Physiotherapy Laboratory, Nucleus of Research in Physical Exercise, Federal University of São Carlos, São Carlos, Brazil; 3Department of Physiotherapy, Federal University of Amazonas, Manaus, AM, Brazil; 4Course of Physiotherapy, Department of Health and Physical Education, University of Santa Cruz do Sul, Rio Grande do Sul, Brazil; 5Pulmonary Rehabilitation Program, Santa Cruz Hospital, Santa Cruz do Sul, Rio Grande do Sul, Brazil Purpose: To evaluate the heart rate variability (HRV) indices and heart rate (HR) responses during isometric contraction (IC) and Valsalva maneuver (VM) in COPD patients. Methods: Twenty-two stable moderate to severe COPD patients were evaluated. R-R intervals were recorded (monitor Polar® S810i) during dominant upper limb IC (2 minutes). Stable signals were analyzed by Kubios HRV® software. Indices of HRV were computed in the time domain (mean HR; square root of the mean squared differences of successive RR intervals [RMSSD] and HRV triangular index [RR tri index]) and in the frequency domain (high frequency [HF]; low frequency [LF] and LF/HF ratio). The HR responses were evaluated at rest, at the peak and at the nadir of the VM (15 seconds). The Valsalva index was also calculated. Results: During IC: time domain indices (mean HR increased [P=0.001], RMSSD, and RR tri index decreased [P=0.005 and P=0.005, respectively]); frequency domain indices (LF increased [P=0.033] and HF decreased [P=0.002]); associations were found between forced expiratory volume in 1 second (FEV1) vs RMSSD (P=0.04; r=–0.55), FEV1 vs HR (P=0.04; r=–0.48), forced vital capacity (FVC) vs RMSSD (P=0.05; r=–0.62), maximum inspiratory pressure (MIP) vs HF (P=0.02; r=0.68). FEV1 and FVC justified 30% of mean HR. During VM: HR increased (P=0.01); the nadir showed normal bradycardic response; the Valsalva index was =0.7. Conclusion: COPD patients responded properly to the upper limb IC and to the VM; however, HR recovery during VM was impaired in these patients. The severity of the disease and MIP were associated with increased parasympathetic modulation and higher chronotropic response. Keywords: heart rate, autonomic nervous system, COPD, isometric contraction, Valsalva maneuver |
first_indexed | 2024-12-14T00:13:18Z |
format | Article |
id | doaj.art-61215e94b331403e807ca0b530943d3e |
institution | Directory Open Access Journal |
issn | 1178-2005 |
language | English |
last_indexed | 2024-12-14T00:13:18Z |
publishDate | 2017-03-01 |
publisher | Dove Medical Press |
record_format | Article |
series | International Journal of COPD |
spelling | doaj.art-61215e94b331403e807ca0b530943d3e2022-12-21T23:25:40ZengDove Medical PressInternational Journal of COPD1178-20052017-03-01Volume 1284985731839Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients?Goulart CLCabiddu RSchneiders PBAntunes San Martin ETrimer RBorghi-Silva Ada Silva ALGCássia da Luz Goulart,1 Ramona Cabiddu,2 Paloma de Borba Schneiders,1 Elisabete Antunes San Martin,1 Renata Trimer,3 Audrey Borghi-Silva,2 Andréa Lúcia Gonçalves da Silva4,5 1Course of Physiotherapy, University of Santa Cruz do Sul, Rio Grande do Sul, Brazil; 2Cardiopulmonary Physiotherapy Laboratory, Nucleus of Research in Physical Exercise, Federal University of São Carlos, São Carlos, Brazil; 3Department of Physiotherapy, Federal University of Amazonas, Manaus, AM, Brazil; 4Course of Physiotherapy, Department of Health and Physical Education, University of Santa Cruz do Sul, Rio Grande do Sul, Brazil; 5Pulmonary Rehabilitation Program, Santa Cruz Hospital, Santa Cruz do Sul, Rio Grande do Sul, Brazil Purpose: To evaluate the heart rate variability (HRV) indices and heart rate (HR) responses during isometric contraction (IC) and Valsalva maneuver (VM) in COPD patients. Methods: Twenty-two stable moderate to severe COPD patients were evaluated. R-R intervals were recorded (monitor Polar® S810i) during dominant upper limb IC (2 minutes). Stable signals were analyzed by Kubios HRV® software. Indices of HRV were computed in the time domain (mean HR; square root of the mean squared differences of successive RR intervals [RMSSD] and HRV triangular index [RR tri index]) and in the frequency domain (high frequency [HF]; low frequency [LF] and LF/HF ratio). The HR responses were evaluated at rest, at the peak and at the nadir of the VM (15 seconds). The Valsalva index was also calculated. Results: During IC: time domain indices (mean HR increased [P=0.001], RMSSD, and RR tri index decreased [P=0.005 and P=0.005, respectively]); frequency domain indices (LF increased [P=0.033] and HF decreased [P=0.002]); associations were found between forced expiratory volume in 1 second (FEV1) vs RMSSD (P=0.04; r=–0.55), FEV1 vs HR (P=0.04; r=–0.48), forced vital capacity (FVC) vs RMSSD (P=0.05; r=–0.62), maximum inspiratory pressure (MIP) vs HF (P=0.02; r=0.68). FEV1 and FVC justified 30% of mean HR. During VM: HR increased (P=0.01); the nadir showed normal bradycardic response; the Valsalva index was =0.7. Conclusion: COPD patients responded properly to the upper limb IC and to the VM; however, HR recovery during VM was impaired in these patients. The severity of the disease and MIP were associated with increased parasympathetic modulation and higher chronotropic response. Keywords: heart rate, autonomic nervous system, COPD, isometric contraction, Valsalva maneuverhttps://www.dovepress.com/is-cardiac-autonomic-modulation-during-upper-limb-isometric-contractio-peer-reviewed-article-COPDheart rateautonomic nervous systemCOPDisometric contractionValsalva maneuver. |
spellingShingle | Goulart CL Cabiddu R Schneiders PB Antunes San Martin E Trimer R Borghi-Silva A da Silva ALG Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients? International Journal of COPD heart rate autonomic nervous system COPD isometric contraction Valsalva maneuver. |
title | Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients? |
title_full | Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients? |
title_fullStr | Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients? |
title_full_unstemmed | Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients? |
title_short | Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients? |
title_sort | is cardiac autonomic modulation during upper limb isometric contraction and valsalva maneuver impaired in copd patients |
topic | heart rate autonomic nervous system COPD isometric contraction Valsalva maneuver. |
url | https://www.dovepress.com/is-cardiac-autonomic-modulation-during-upper-limb-isometric-contractio-peer-reviewed-article-COPD |
work_keys_str_mv | AT goulartcl iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients AT cabiddur iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients AT schneiderspb iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients AT antunessanmartine iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients AT trimerr iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients AT borghisilvaa iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients AT dasilvaalg iscardiacautonomicmodulationduringupperlimbisometriccontractionandvalsalvamaneuverimpairedincopdpatients |