Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging

Omar Alshehri,1 Ahmed M Abdelaal,2 Ghufran Abudawood,1 Muhammad A Khan,3 Saud Alsharif,4 Hassan Hijazi,1 AlBaraa AlQassimi1 1Ophthalmology Department, King Fahad Armed Forces Hospital, Jeddah, Saudi Arabia; 2Ophthalmology Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia; 3Epidem...

Full description

Bibliographic Details
Main Authors: Alshehri O, Abdelaal AM, Abudawood G, Khan MA, Alsharif S, Hijazi H, AlQassimi A
Format: Article
Language:English
Published: Dove Medical Press 2022-08-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/normative-values-for-corneal-tomography-and-comparison-of-both-eyes-in-peer-reviewed-fulltext-article-OPTH
_version_ 1818497214729682944
author Alshehri O
Abdelaal AM
Abudawood G
Khan MA
Alsharif S
Hijazi H
AlQassimi A
author_facet Alshehri O
Abdelaal AM
Abudawood G
Khan MA
Alsharif S
Hijazi H
AlQassimi A
author_sort Alshehri O
collection DOAJ
description Omar Alshehri,1 Ahmed M Abdelaal,2 Ghufran Abudawood,1 Muhammad A Khan,3 Saud Alsharif,4 Hassan Hijazi,1 AlBaraa AlQassimi1 1Ophthalmology Department, King Fahad Armed Forces Hospital, Jeddah, Saudi Arabia; 2Ophthalmology Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia; 3Epidemiology and Public Health Department, King Saud Bin Abdulaziz University, Jeddah, Saudi Arabia; 4Faculty of Medicine, Imam Mohammad Ibn Saud Islamic University, Riyadh, Saudi ArabiaCorrespondence: Ahmed M Abdelaal, Ophthalmology Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia, Tel +966 56 371 8789, Email ahmed3bdelaal@gmail.comPurpose: Anterior segment evaluation using Scheimpflug imaging with the Pentacam scanner allows the acquisition of a plethora of information. It aids in screening and diagnosing corneal pathologies and determining suitability for keratorefractive procedures. This research has significant benefits in terms of establishing normative tomographic values, which is crucial in countries where Keratoconus (KC) is more prevalent, especially among young age group, along with aiding future research in the field of refractive surgery by providing relevant normative data.Methods: A retrospective review of digital corneal tomography images for a group of medically and ophthalmologically free males aged between 18 and 21 years with 20/20 unaided distant visual acuity was performed.Results: A total of 1272 subjects (2544 eyes) were included. Findings revealed a mean maximal corneal curvature (Kmax) of 42.91 ± 1.40D (range 36.90– 47.80D). The mean flat keratometry (K1) was 41.87 ± 1.31D (range 36.00– 46.40D). The mean steep keratometry (K2) was 42.66 ± 1.35D (range 36.70– 47.60D). The mean corneal astigmatism (CA) was 0.79 ± 0.37D (range 0.00D-2.30D). The mean central corneal thickness (CCT) was 558.53 ± 33.84 μm (range 421– 677 μm). The mean thinnest corneal location thickness (TCLT) was 551.64 ± 34.08 μm (range 417– 669μm). The mean corneal diameter (CD) and anterior chamber depth (ACD) were 12.13 ± 0.39 mm (range 10.50– 13.60 mm) and 3.12 ± 0.29 mm (range 2.08– 4.08 mm), respectively. The median differences between both eyes of the same subject were as follows: kmax difference of 0.20D (IQR 0.1– 0.4); K1, K2 and CA difference of 0.20D (IQR 0.1– 0.3) for all 3 parameters; CCT and TCLT difference of 5.00 μm (IQR 3.0– 9.0) and 6.00 μm (IQR 3.0– 10.0), respectively; CD difference of 0.10 mm (IQR 0.0– 0.1); and ACD difference of 0.04 (IQR 0.02– 0.06).Conclusion: We believe our data can aid in establishing normative tomographic values and acceptable differences between both eyes. Our data may also help detect subtle corneal pathology and be useful for researchers and innovators in the field of ophthalmology.Keywords: corneal tomography, corneal topography, pentacam, normative values, Saudi Arabia
first_indexed 2024-12-10T18:42:55Z
format Article
id doaj.art-612a6f2f97c6426498779abe4c3fc9f9
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-12-10T18:42:55Z
publishDate 2022-08-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-612a6f2f97c6426498779abe4c3fc9f92022-12-22T01:37:36ZengDove Medical PressClinical Ophthalmology1177-54832022-08-01Volume 162631263777374Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug ImagingAlshehri OAbdelaal AMAbudawood GKhan MAAlsharif SHijazi HAlQassimi AOmar Alshehri,1 Ahmed M Abdelaal,2 Ghufran Abudawood,1 Muhammad A Khan,3 Saud Alsharif,4 Hassan Hijazi,1 AlBaraa AlQassimi1 1Ophthalmology Department, King Fahad Armed Forces Hospital, Jeddah, Saudi Arabia; 2Ophthalmology Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia; 3Epidemiology and Public Health Department, King Saud Bin Abdulaziz University, Jeddah, Saudi Arabia; 4Faculty of Medicine, Imam Mohammad Ibn Saud Islamic University, Riyadh, Saudi ArabiaCorrespondence: Ahmed M Abdelaal, Ophthalmology Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia, Tel +966 56 371 8789, Email ahmed3bdelaal@gmail.comPurpose: Anterior segment evaluation using Scheimpflug imaging with the Pentacam scanner allows the acquisition of a plethora of information. It aids in screening and diagnosing corneal pathologies and determining suitability for keratorefractive procedures. This research has significant benefits in terms of establishing normative tomographic values, which is crucial in countries where Keratoconus (KC) is more prevalent, especially among young age group, along with aiding future research in the field of refractive surgery by providing relevant normative data.Methods: A retrospective review of digital corneal tomography images for a group of medically and ophthalmologically free males aged between 18 and 21 years with 20/20 unaided distant visual acuity was performed.Results: A total of 1272 subjects (2544 eyes) were included. Findings revealed a mean maximal corneal curvature (Kmax) of 42.91 ± 1.40D (range 36.90– 47.80D). The mean flat keratometry (K1) was 41.87 ± 1.31D (range 36.00– 46.40D). The mean steep keratometry (K2) was 42.66 ± 1.35D (range 36.70– 47.60D). The mean corneal astigmatism (CA) was 0.79 ± 0.37D (range 0.00D-2.30D). The mean central corneal thickness (CCT) was 558.53 ± 33.84 μm (range 421– 677 μm). The mean thinnest corneal location thickness (TCLT) was 551.64 ± 34.08 μm (range 417– 669μm). The mean corneal diameter (CD) and anterior chamber depth (ACD) were 12.13 ± 0.39 mm (range 10.50– 13.60 mm) and 3.12 ± 0.29 mm (range 2.08– 4.08 mm), respectively. The median differences between both eyes of the same subject were as follows: kmax difference of 0.20D (IQR 0.1– 0.4); K1, K2 and CA difference of 0.20D (IQR 0.1– 0.3) for all 3 parameters; CCT and TCLT difference of 5.00 μm (IQR 3.0– 9.0) and 6.00 μm (IQR 3.0– 10.0), respectively; CD difference of 0.10 mm (IQR 0.0– 0.1); and ACD difference of 0.04 (IQR 0.02– 0.06).Conclusion: We believe our data can aid in establishing normative tomographic values and acceptable differences between both eyes. Our data may also help detect subtle corneal pathology and be useful for researchers and innovators in the field of ophthalmology.Keywords: corneal tomography, corneal topography, pentacam, normative values, Saudi Arabiahttps://www.dovepress.com/normative-values-for-corneal-tomography-and-comparison-of-both-eyes-in-peer-reviewed-fulltext-article-OPTHcorneal tomographycorneal topographypentacamnormative valuessaudi arabia.
spellingShingle Alshehri O
Abdelaal AM
Abudawood G
Khan MA
Alsharif S
Hijazi H
AlQassimi A
Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging
Clinical Ophthalmology
corneal tomography
corneal topography
pentacam
normative values
saudi arabia.
title Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging
title_full Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging
title_fullStr Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging
title_full_unstemmed Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging
title_short Normative Values for Corneal Tomography and Comparison of Both Eyes in Young Saudi Males with 20/20 Vision Using Pentacam-HR Scheimpflug Imaging
title_sort normative values for corneal tomography and comparison of both eyes in young saudi males with 20 20 vision using pentacam hr scheimpflug imaging
topic corneal tomography
corneal topography
pentacam
normative values
saudi arabia.
url https://www.dovepress.com/normative-values-for-corneal-tomography-and-comparison-of-both-eyes-in-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT alshehrio normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging
AT abdelaalam normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging
AT abudawoodg normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging
AT khanma normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging
AT alsharifs normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging
AT hijazih normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging
AT alqassimia normativevaluesforcornealtomographyandcomparisonofbotheyesinyoungsaudimaleswith2020visionusingpentacamhrscheimpflugimaging