Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290
An original R410A wall room air conditioner was retrofitted with R290 for performance experiments. The R410A wall room air conditioner has a COP and a refrigerating capacity 6.0597and 1929.3 W respectively. In this study, the compressor R410A wall room air conditioner compressor was replaced with an...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201815901051 |
_version_ | 1818443717113020416 |
---|---|
author | Fajar TK Berkah Nicolas Dipto I Geraldus |
author_facet | Fajar TK Berkah Nicolas Dipto I Geraldus |
author_sort | Fajar TK Berkah |
collection | DOAJ |
description | An original R410A wall room air conditioner was retrofitted with R290 for performance experiments. The R410A wall room air conditioner has a COP and a refrigerating capacity 6.0597and 1929.3 W respectively. In this study, the compressor R410A wall room air conditioner compressor was replaced with an R22 which is compatible. Mass R290 charged into the wall room air conditioner was 33.88%, 38.12% and 42.35%. Refrigerating capacity obtained was 1837 W, 1848.2 W and 2008.4W, while the COP was 5.2014, 5.0294, and 5.3275. The results obtained the R410A wall room air conditioner performance better than if the air conditioning machine retrofitted with R290. |
first_indexed | 2024-12-14T19:04:28Z |
format | Article |
id | doaj.art-6141106b8ff342b19bc023d96224bfec |
institution | Directory Open Access Journal |
issn | 2261-236X |
language | English |
last_indexed | 2024-12-14T19:04:28Z |
publishDate | 2018-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | MATEC Web of Conferences |
spelling | doaj.art-6141106b8ff342b19bc023d96224bfec2022-12-21T22:50:53ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011590105110.1051/matecconf/201815901051matecconf_ijcaet-isampe2018_01051Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290Fajar TK BerkahNicolas Dipto I GeraldusAn original R410A wall room air conditioner was retrofitted with R290 for performance experiments. The R410A wall room air conditioner has a COP and a refrigerating capacity 6.0597and 1929.3 W respectively. In this study, the compressor R410A wall room air conditioner compressor was replaced with an R22 which is compatible. Mass R290 charged into the wall room air conditioner was 33.88%, 38.12% and 42.35%. Refrigerating capacity obtained was 1837 W, 1848.2 W and 2008.4W, while the COP was 5.2014, 5.0294, and 5.3275. The results obtained the R410A wall room air conditioner performance better than if the air conditioning machine retrofitted with R290.https://doi.org/10.1051/matecconf/201815901051 |
spellingShingle | Fajar TK Berkah Nicolas Dipto I Geraldus Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 MATEC Web of Conferences |
title | Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 |
title_full | Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 |
title_fullStr | Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 |
title_full_unstemmed | Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 |
title_short | Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 |
title_sort | experimental performance studies of small wall room air conditioner for r410a retrofitted with r290 |
url | https://doi.org/10.1051/matecconf/201815901051 |
work_keys_str_mv | AT fajartkberkah experimentalperformancestudiesofsmallwallroomairconditionerforr410aretrofittedwithr290 AT nicolasdiptoigeraldus experimentalperformancestudiesofsmallwallroomairconditionerforr410aretrofittedwithr290 |