Design Implication of a Distribution Transformer in Solar Power Plants Based on Its Harmonic Profile
This article presents a comparative analysis for the design considerations for a solar power generation transformer. One of the main existing problems in transformer manufacturing is in the renewable energy field, specifically the solar power generation, where the transformer connected to the invert...
Main Authors: | Iván Rafael Macías Ruiz, Luis Alonso Trujillo Guajardo, Luis Humberto Rodríguez Alfaro, Fernando Salinas Salinas, Johnny Rodríguez Maldonado, Mario Alberto González Vázquez |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-03-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/5/1362 |
Similar Items
-
Prony Method Estimation as a New Approach for Surge Comparison Testing in Turn Insulation Diagnostics for Three Phase Stator Windings
by: Luis Alonso Trujillo Guajardo, et al.
Published: (2023-02-01) -
Prony Method Estimation for Motor Current Signal Analysis Diagnostics in Rotor Cage Induction Motors
by: Luis Alonso Trujillo Guajardo, et al.
Published: (2022-05-01) -
Defining and Specifying Design Considerations for Distribution Transformers in Large-Scale Solar Photovoltaic Plants
by: Bonginkosi A. Thango, et al.
Published: (2022-04-01) -
Harmonic Analysis and Mitigation of Mass Adoption for Electric Vehicle Charging Station (100kW) in Distribution System
by: Mohamad Faizal Ishak, et al.
Published: (2021-06-01) -
An artificial neural network based harmonic distortions estimator for grid- connected power converter-based applications
by: Thamer A.H. Alghamdi, et al.
Published: (2023-04-01)