Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type

The effect of tumbling time (1-9 h), injection rate (20, 30, 40, and 50 %) and k-carrageenan addition (0, 0.25, and 0.5 %) on the rheological characteristics of pork Biceps femoris muscle were assessed. The results of the creep-recovery tests were analyzed using Burger’s equation. Increasing tumblin...

Full description

Bibliographic Details
Main Authors: Livia PĂTRAŞCU, Ina VASILEAN, Petru ALEXE
Format: Article
Language:English
Published: Galati University Press 2014-12-01
Series:Annals of the University Dunarea de Jos of Galati. Fascicle VI: Food Technology
Subjects:
Online Access:http://www.ann.ugal.ro/tpa/Anale%202014/3_Patrascu.pdf
_version_ 1818248590944894976
author Livia PĂTRAŞCU
Ina VASILEAN
Petru ALEXE
author_facet Livia PĂTRAŞCU
Ina VASILEAN
Petru ALEXE
author_sort Livia PĂTRAŞCU
collection DOAJ
description The effect of tumbling time (1-9 h), injection rate (20, 30, 40, and 50 %) and k-carrageenan addition (0, 0.25, and 0.5 %) on the rheological characteristics of pork Biceps femoris muscle were assessed. The results of the creep-recovery tests were analyzed using Burger’s equation. Increasing tumbling time up to 9 h along with injection rate also increased compliance values and decreased viscosity. K-carrageenan addition showed the occurrence of a more gel-like structure of the brine-meat system, causing further increase of the compliance and strain values. Samples injected with brine were more elastic compared to those containing k-carrageenan. A longer mechanical treatment provided a softer like matrix. Mathematical modeling of creep-compliance data showed a decreasing tendency for viscosity values with k-carrageenan addition. Discrete retarded elastic compliance values increased when adding k-carrageenan to meat-brine system. Addition of k-carrageenan did not affect the equilibrium compliance values.
first_indexed 2024-12-12T15:23:02Z
format Article
id doaj.art-61bb4369fe3540a5ae0a1c6b5fb5c15e
institution Directory Open Access Journal
issn 1843-5157
2068-259X
language English
last_indexed 2024-12-12T15:23:02Z
publishDate 2014-12-01
publisher Galati University Press
record_format Article
series Annals of the University Dunarea de Jos of Galati. Fascicle VI: Food Technology
spelling doaj.art-61bb4369fe3540a5ae0a1c6b5fb5c15e2022-12-22T00:20:20ZengGalati University PressAnnals of the University Dunarea de Jos of Galati. Fascicle VI: Food Technology1843-51572068-259X2014-12-013823242Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine typeLivia PĂTRAŞCU0Ina VASILEAN1Petru ALEXE2Dunarea de Jos University of Galati, RomaniaDunarea de Jos University of Galati, RomaniaDunarea de Jos University of Galati, RomaniaThe effect of tumbling time (1-9 h), injection rate (20, 30, 40, and 50 %) and k-carrageenan addition (0, 0.25, and 0.5 %) on the rheological characteristics of pork Biceps femoris muscle were assessed. The results of the creep-recovery tests were analyzed using Burger’s equation. Increasing tumbling time up to 9 h along with injection rate also increased compliance values and decreased viscosity. K-carrageenan addition showed the occurrence of a more gel-like structure of the brine-meat system, causing further increase of the compliance and strain values. Samples injected with brine were more elastic compared to those containing k-carrageenan. A longer mechanical treatment provided a softer like matrix. Mathematical modeling of creep-compliance data showed a decreasing tendency for viscosity values with k-carrageenan addition. Discrete retarded elastic compliance values increased when adding k-carrageenan to meat-brine system. Addition of k-carrageenan did not affect the equilibrium compliance values.http://www.ann.ugal.ro/tpa/Anale%202014/3_Patrascu.pdfcreepcomplianceviscosityBurger’s modelk-carrageenantumbling time
spellingShingle Livia PĂTRAŞCU
Ina VASILEAN
Petru ALEXE
Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type
Annals of the University Dunarea de Jos of Galati. Fascicle VI: Food Technology
creep
compliance
viscosity
Burger’s model
k-carrageenan
tumbling time
title Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type
title_full Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type
title_fullStr Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type
title_full_unstemmed Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type
title_short Rheological behavior of pork Biceps femoris muscle influenced by injection-tumbling process and brine type
title_sort rheological behavior of pork biceps femoris muscle influenced by injection tumbling process and brine type
topic creep
compliance
viscosity
Burger’s model
k-carrageenan
tumbling time
url http://www.ann.ugal.ro/tpa/Anale%202014/3_Patrascu.pdf
work_keys_str_mv AT liviapatrascu rheologicalbehaviorofporkbicepsfemorismuscleinfluencedbyinjectiontumblingprocessandbrinetype
AT inavasilean rheologicalbehaviorofporkbicepsfemorismuscleinfluencedbyinjectiontumblingprocessandbrinetype
AT petrualexe rheologicalbehaviorofporkbicepsfemorismuscleinfluencedbyinjectiontumblingprocessandbrinetype