Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model

Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the fol...

Full description

Bibliographic Details
Main Authors: Álvaro Zubizarreta-Macho, Alberto Albaladejo Martínez, Carlos Falcão Costa, Norberto Quispe-López, Ruben Agustín-Panadero, Jesús Mena-Álvarez
Format: Article
Language:English
Published: BMC 2021-04-01
Series:BMC Oral Health
Subjects:
Online Access:https://doi.org/10.1186/s12903-021-01538-8
Description
Summary:Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodontic files was registered. The results were analyzed by ANOVA and Weibull statistics. Results Statistically significant differences were found when the number of cycles of in-and-out movement and the time to failure of ReFlex Dynamic and Reciproc reciprocating movement (p < 0.001) and between ReFlex Smart and Reciproc reciprocating movement (p < 0.001) were compared in pairs. However, no statistically significant differences were observed between time to failure and number of cycles of in-and-out movement of ReFlex Dynamic and ReFlex Smart reciprocating movement (p = 0.253). Conclusions The ReFlex Smart reciprocating movement increased the cyclic fatigue resistance of endodontic reciprocating files compared with traditional reciprocating movement.
ISSN:1472-6831