Comparison of Fluorescence Flow Cytometry and Culture Method for Identification of Urine Specimens with No Growth
Introduction: In clinical microbiology laboratories, urine specimens are the most frequently analysed specimens. Rapid and reliable methods are needed especially for no growth culture. In this study, the performance of the Sysmex UF-1000i instrument was compared with the culture results for the purp...
Main Authors: | Şölen DALDABAN DİNÇER, Özgür YANILMAZ, Ülkü ORAL ZEYTİNLİ, Ertan ÖZYURT, Ramazan AYAŞ, Sebahat AKSARAY |
---|---|
Format: | Article |
Language: | English |
Published: |
Bilimsel Tip Yayinevi
2019-12-01
|
Series: | Flora Infeksiyon Hastalıkları ve Klinik Mikrobiyoloji Dergisi |
Subjects: | |
Online Access: | http://www.floradergisi.org/getFileContent.aspx?op=REDPDF&file_name=2019-24-04-321-328.pdf |
Similar Items
-
Characteristics of Secondary Bloodstream Infections at the Region of İstanbul Northern Anatolian Association of Public Hospitals
by: Şölen Daldaban Dinçer, et al.
Published: (2022-03-01) -
Urine Flow Cytometry and Dipstick Analysis in Diagnosing Bacteriuria and Urinary Tract Infections among Adults in the Emergency Department—A Diagnostic Accuracy Trial
by: Mathias Amdi Hertz, et al.
Published: (2024-02-01) -
Urine Flow Cytometry Parameter Cannot Safely Predict Contamination of Urine—A Cohort Study of a Swiss Emergency Department Using Machine Learning Techniques
by: Martin Müller, et al.
Published: (2022-04-01) -
Urinary creatinine concentration and urine color as indicators of specimen validity test
by: Jaehyeong Park, et al.
Published: (2023-09-01) -
Flow cytometry : first principles /
by: 416619 Givan, Alice Longobardi
Published: (2001)