Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks

At least 24 liquefied natural gas (LNG) rollover incidents have been reported since 1960. During rollover, because of the heat ingress through the tank walls, a stratified LNG may be suddenly homogenized while releasing massive amounts of vapor. It can result in an overpressure in the tank and signi...

Full description

Bibliographic Details
Main Authors: Tomasz Włodek, Mariusz Łaciak
Format: Article
Language:English
Published: MDPI AG 2023-11-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/22/7666
_version_ 1827639922890113024
author Tomasz Włodek
Mariusz Łaciak
author_facet Tomasz Włodek
Mariusz Łaciak
author_sort Tomasz Włodek
collection DOAJ
description At least 24 liquefied natural gas (LNG) rollover incidents have been reported since 1960. During rollover, because of the heat ingress through the tank walls, a stratified LNG may be suddenly homogenized while releasing massive amounts of vapor. It can result in an overpressure in the tank and significant amounts of potentially explosive LNG vapor being vented out. Both of these factors represent considerable hazards. Rollover is a physical mixing process in a single tank with two or more different cells of LNG of different compositions, temperatures, and densities that can manifest in large boil-off rates. It can exceed venting equipment capacities, and vapor pressure in tank increases rapidly and in extreme cases can lead to tank damage. This paper presents numerical approach for determination of time of rollover occurrence in storage tank. The presented model is based on the energy balance of the stratified cryogenic liquid and the gas phase as separate three thermodynamic systems in the storage tank. As a result of proposed model, for the adopted assumptions and cylindrical tank volume of 78,500 m<sup>3</sup>, the approximate time of the rollover occurrence was determined for two cases. In the first case, for heavier LNG, the rollover phenomenon will occur 193.25 h after the start of the calculations from the assumed initial conditions. In the second case, for light LNG with a higher initial liquid level in the tank, the rollover will occur after 150.25 h.
first_indexed 2024-03-09T16:51:41Z
format Article
id doaj.art-625c748d54794a888ef303398d7709cc
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T16:51:41Z
publishDate 2023-11-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-625c748d54794a888ef303398d7709cc2023-11-24T14:40:45ZengMDPI AGEnergies1996-10732023-11-011622766610.3390/en16227666Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage TanksTomasz Włodek0Mariusz Łaciak1Natural Gas Engineering Department, Drilling, Oil and Gas Faculty, AGH University of Krakow, 30 Mickiewicza Av., 30-059 Krakow, PolandNatural Gas Engineering Department, Drilling, Oil and Gas Faculty, AGH University of Krakow, 30 Mickiewicza Av., 30-059 Krakow, PolandAt least 24 liquefied natural gas (LNG) rollover incidents have been reported since 1960. During rollover, because of the heat ingress through the tank walls, a stratified LNG may be suddenly homogenized while releasing massive amounts of vapor. It can result in an overpressure in the tank and significant amounts of potentially explosive LNG vapor being vented out. Both of these factors represent considerable hazards. Rollover is a physical mixing process in a single tank with two or more different cells of LNG of different compositions, temperatures, and densities that can manifest in large boil-off rates. It can exceed venting equipment capacities, and vapor pressure in tank increases rapidly and in extreme cases can lead to tank damage. This paper presents numerical approach for determination of time of rollover occurrence in storage tank. The presented model is based on the energy balance of the stratified cryogenic liquid and the gas phase as separate three thermodynamic systems in the storage tank. As a result of proposed model, for the adopted assumptions and cylindrical tank volume of 78,500 m<sup>3</sup>, the approximate time of the rollover occurrence was determined for two cases. In the first case, for heavier LNG, the rollover phenomenon will occur 193.25 h after the start of the calculations from the assumed initial conditions. In the second case, for light LNG with a higher initial liquid level in the tank, the rollover will occur after 150.25 h.https://www.mdpi.com/1996-1073/16/22/7666LNGrolloverevaporationboil-off gasrollover model
spellingShingle Tomasz Włodek
Mariusz Łaciak
Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks
Energies
LNG
rollover
evaporation
boil-off gas
rollover model
title Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks
title_full Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks
title_fullStr Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks
title_full_unstemmed Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks
title_short Rollover Prevention Model for Stratified Liquefied Natural Gas in Storage Tanks
title_sort rollover prevention model for stratified liquefied natural gas in storage tanks
topic LNG
rollover
evaporation
boil-off gas
rollover model
url https://www.mdpi.com/1996-1073/16/22/7666
work_keys_str_mv AT tomaszwłodek rolloverpreventionmodelforstratifiedliquefiednaturalgasinstoragetanks
AT mariuszłaciak rolloverpreventionmodelforstratifiedliquefiednaturalgasinstoragetanks