Measurement of total scatter factor for stereotactic cones with plastic scintillation detector

Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this st...

Full description

Bibliographic Details
Main Authors: Suresh H Chaudhari, Rishabh Dobhal, Rajesh A Kinhikar, Sudarshan S Kadam, Deepak D Deshpande
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2017;volume=42;issue=1;spage=9;epage=13;aulast=Chaudhari
_version_ 1828520923120009216
author Suresh H Chaudhari
Rishabh Dobhal
Rajesh A Kinhikar
Sudarshan S Kadam
Deepak D Deshpande
author_facet Suresh H Chaudhari
Rishabh Dobhal
Rajesh A Kinhikar
Sudarshan S Kadam
Deepak D Deshpande
author_sort Suresh H Chaudhari
collection DOAJ
description Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be −1.3%, 1.9%, −0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data.
first_indexed 2024-12-11T19:39:34Z
format Article
id doaj.art-628a74cdd2e14136ab1572421daf78a7
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-12-11T19:39:34Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-628a74cdd2e14136ab1572421daf78a72022-12-22T00:53:03ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132017-01-0142191310.4103/jmp.JMP_114_16Measurement of total scatter factor for stereotactic cones with plastic scintillation detectorSuresh H ChaudhariRishabh DobhalRajesh A KinhikarSudarshan S KadamDeepak D DeshpandeAdvanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be −1.3%, 1.9%, −0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2017;volume=42;issue=1;spage=9;epage=13;aulast=ChaudhariPlastic scintillatorsmall field dosimetrytotal scatter factor
spellingShingle Suresh H Chaudhari
Rishabh Dobhal
Rajesh A Kinhikar
Sudarshan S Kadam
Deepak D Deshpande
Measurement of total scatter factor for stereotactic cones with plastic scintillation detector
Journal of Medical Physics
Plastic scintillator
small field dosimetry
total scatter factor
title Measurement of total scatter factor for stereotactic cones with plastic scintillation detector
title_full Measurement of total scatter factor for stereotactic cones with plastic scintillation detector
title_fullStr Measurement of total scatter factor for stereotactic cones with plastic scintillation detector
title_full_unstemmed Measurement of total scatter factor for stereotactic cones with plastic scintillation detector
title_short Measurement of total scatter factor for stereotactic cones with plastic scintillation detector
title_sort measurement of total scatter factor for stereotactic cones with plastic scintillation detector
topic Plastic scintillator
small field dosimetry
total scatter factor
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2017;volume=42;issue=1;spage=9;epage=13;aulast=Chaudhari
work_keys_str_mv AT sureshhchaudhari measurementoftotalscatterfactorforstereotacticconeswithplasticscintillationdetector
AT rishabhdobhal measurementoftotalscatterfactorforstereotacticconeswithplasticscintillationdetector
AT rajeshakinhikar measurementoftotalscatterfactorforstereotacticconeswithplasticscintillationdetector
AT sudarshanskadam measurementoftotalscatterfactorforstereotacticconeswithplasticscintillationdetector
AT deepakddeshpande measurementoftotalscatterfactorforstereotacticconeswithplasticscintillationdetector