Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator
The evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-09-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/19/6069 |
_version_ | 1797516644799479808 |
---|---|
author | Yu Sun Rijing Zhao Siyuan Wu Dong Huang |
author_facet | Yu Sun Rijing Zhao Siyuan Wu Dong Huang |
author_sort | Yu Sun |
collection | DOAJ |
description | The evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved to recover evaporator capacity loss. However, quantitative design principles of non-uniform fin distribution are lacking. A quasi-static frosting evaporator model is established and experimentally verified considering a three-dimensional (3D) evaporator, 1D frost growth and 1D non-uniform fin distribution. An optimization method for row-by-row fin distribution of a multi-row frosting evaporator is proposed based on the air pressure drop’s increase rate. When the increase rate in the air pressure drop of each row is almost equal, the smallest overall evaporator pressure drop is obtained, leading to the highest air flowrate and the greatest evaporator capacity. By applying the method, the air flowrate and the evaporator capacity increase by 5.5% and 4.6%, respectively, compared to the original fin distribution scheme. Moreover, the robustness of the optimization method is validated under wide temperature and humidity operating conditions. An equivalent implementation under an initial no-frost condition is also proposed to facilitate the optimization method without calculating the whole frosting process. |
first_indexed | 2024-03-10T07:03:46Z |
format | Article |
id | doaj.art-62947d2ab28847e198ba85390ee48a18 |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-03-10T07:03:46Z |
publishDate | 2021-09-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-62947d2ab28847e198ba85390ee48a182023-11-22T15:58:49ZengMDPI AGEnergies1996-10732021-09-011419606910.3390/en14196069Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting EvaporatorYu Sun0Rijing Zhao1Siyuan Wu2Dong Huang3Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaDepartment of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaDepartment of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaDepartment of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaThe evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved to recover evaporator capacity loss. However, quantitative design principles of non-uniform fin distribution are lacking. A quasi-static frosting evaporator model is established and experimentally verified considering a three-dimensional (3D) evaporator, 1D frost growth and 1D non-uniform fin distribution. An optimization method for row-by-row fin distribution of a multi-row frosting evaporator is proposed based on the air pressure drop’s increase rate. When the increase rate in the air pressure drop of each row is almost equal, the smallest overall evaporator pressure drop is obtained, leading to the highest air flowrate and the greatest evaporator capacity. By applying the method, the air flowrate and the evaporator capacity increase by 5.5% and 4.6%, respectively, compared to the original fin distribution scheme. Moreover, the robustness of the optimization method is validated under wide temperature and humidity operating conditions. An equivalent implementation under an initial no-frost condition is also proposed to facilitate the optimization method without calculating the whole frosting process.https://www.mdpi.com/1996-1073/14/19/6069finned tube evaporatorfrostfin distributionoptimization method |
spellingShingle | Yu Sun Rijing Zhao Siyuan Wu Dong Huang Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator Energies finned tube evaporator frost fin distribution optimization method |
title | Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator |
title_full | Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator |
title_fullStr | Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator |
title_full_unstemmed | Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator |
title_short | Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator |
title_sort | proposal robustness analysis and equivalent implementation of optimization method for row by row fin distribution in multi row frosting evaporator |
topic | finned tube evaporator frost fin distribution optimization method |
url | https://www.mdpi.com/1996-1073/14/19/6069 |
work_keys_str_mv | AT yusun proposalrobustnessanalysisandequivalentimplementationofoptimizationmethodforrowbyrowfindistributioninmultirowfrostingevaporator AT rijingzhao proposalrobustnessanalysisandequivalentimplementationofoptimizationmethodforrowbyrowfindistributioninmultirowfrostingevaporator AT siyuanwu proposalrobustnessanalysisandequivalentimplementationofoptimizationmethodforrowbyrowfindistributioninmultirowfrostingevaporator AT donghuang proposalrobustnessanalysisandequivalentimplementationofoptimizationmethodforrowbyrowfindistributioninmultirowfrostingevaporator |