Percutaneous Suspensory Stabilization of Chronic Distal Radioulnar Joint (DRUJ) Dislocation Using an Adjustable Loop Endobutton Construct: Case Report

Abstract Chronic distal radioulnar joint (DRUJ) dislocation has been treated historically with complex osteotomies and reconstructive procedures, often resulting in intractable stiffness and loss of function. It is desirable to use a technique of fixation that will not only restore the wrist biomech...

Full description

Bibliographic Details
Main Authors: Mohammed Schezan Iqbal, Anil Kumar Mishra, Rajiv Kaul
Format: Article
Language:English
Published: Thieme Revinter Publicações Ltda. 2023-08-01
Series:Revista Brasileira de Ortopedia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162023000200351&tlng=en
Description
Summary:Abstract Chronic distal radioulnar joint (DRUJ) dislocation has been treated historically with complex osteotomies and reconstructive procedures, often resulting in intractable stiffness and loss of function. It is desirable to use a technique of fixation that will not only restore the wrist biomechanics but also be cosmetically appealing to the individual. We present a novel technique of reduction and fixation of a chronically dislocated DRUJ in a 26-year-old male using a minimally invasive approach, with successful restoration of DRUJ function and no postoperative complications.