Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method

The main goal of the research is a diagnostic assessment of polluted water leaks from the chemical waste landfill site using the self-potential method integrated with other methods. The following tasks were to be solved: locating zones of contaminated water leakage from the drainage canals; detectin...

Full description

Bibliographic Details
Main Authors: A. P. Gusev, V. L. Molyarenko, A. I. Pavlovsky, I. O. Prilutsky, S. V. Andrushko
Format: Article
Language:English
Published: Perm Sate National Research University 2022-04-01
Series:Vestnik Permskogo Universiteta: Seriâ Geologiâ
Subjects:
Online Access:http://geology-vestnik.psu.ru/index.php/geology/article/view/432
_version_ 1811165480974548992
author A. P. Gusev
V. L. Molyarenko
A. I. Pavlovsky
I. O. Prilutsky
S. V. Andrushko
author_facet A. P. Gusev
V. L. Molyarenko
A. I. Pavlovsky
I. O. Prilutsky
S. V. Andrushko
author_sort A. P. Gusev
collection DOAJ
description The main goal of the research is a diagnostic assessment of polluted water leaks from the chemical waste landfill site using the self-potential method integrated with other methods. The following tasks were to be solved: locating zones of contaminated water leakage from the drainage canals; detecting polluted water leaks from the sludge reservoir; identifying the discharge zones of contaminated groundwater into the swamps adjacent to the landfill. Electrical prospecting equipment ERA-MAX with non-polarizable electrodes of the VIRG system was used for field measurements. Two measuring techniques of the self-potential method were used: the fixed-base method (the measurement interval was 5 m) and the potential gradient method (measuring line MN = 5 m). The additional methods were as follows: geomagnetic microsurvey and phytoindication. The following diagnostic indicators were estab-lished for the zones of infiltration of contaminated waters from canals and sludge reservoirs: negative fixed-base potential anomalies or negative potential gradient anomalies of the natural electric field, which are characterized by the amplitude of 10-40 mV. The area of discharge of polluted groundwater into the surficial unit is indicated by a positive anomaly of the natural electric field (+ 20-47 mV), spatially associated with the zone of degradation of swamp vegetation.
first_indexed 2024-04-10T15:37:45Z
format Article
id doaj.art-62c5a3a7b6284f98a6aa3e4915016f00
institution Directory Open Access Journal
issn 1994-3601
2313-4798
language English
last_indexed 2024-04-10T15:37:45Z
publishDate 2022-04-01
publisher Perm Sate National Research University
record_format Article
series Vestnik Permskogo Universiteta: Seriâ Geologiâ
spelling doaj.art-62c5a3a7b6284f98a6aa3e4915016f002023-02-12T22:16:29ZengPerm Sate National Research UniversityVestnik Permskogo Universiteta: Seriâ Geologiâ1994-36012313-47982022-04-01211909710.17072/psu.geol.21.1.90354Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential MethodA. P. Gusev0V. L. Molyarenko1A. I. Pavlovsky2I. O. Prilutsky3S. V. Andrushko4Гомельский государственный университет имени Франциска Скорины, 246019, Гомель, ул. Советская, 104.Гомельский государственный университет имени Франциска Скорины, 246019, Гомель, ул. Советская, 104.Гомельский государственный университет имени Франциска Скорины, 246019, Гомель, ул. Советская, 104.Гомельский государственный университет имени Франциска Скорины, 246019, Гомель, ул. Советская, 104.Гомельский государственный университет имени Франциска Скорины, 246019, Гомель, ул. Советская, 104.The main goal of the research is a diagnostic assessment of polluted water leaks from the chemical waste landfill site using the self-potential method integrated with other methods. The following tasks were to be solved: locating zones of contaminated water leakage from the drainage canals; detecting polluted water leaks from the sludge reservoir; identifying the discharge zones of contaminated groundwater into the swamps adjacent to the landfill. Electrical prospecting equipment ERA-MAX with non-polarizable electrodes of the VIRG system was used for field measurements. Two measuring techniques of the self-potential method were used: the fixed-base method (the measurement interval was 5 m) and the potential gradient method (measuring line MN = 5 m). The additional methods were as follows: geomagnetic microsurvey and phytoindication. The following diagnostic indicators were estab-lished for the zones of infiltration of contaminated waters from canals and sludge reservoirs: negative fixed-base potential anomalies or negative potential gradient anomalies of the natural electric field, which are characterized by the amplitude of 10-40 mV. The area of discharge of polluted groundwater into the surficial unit is indicated by a positive anomaly of the natural electric field (+ 20-47 mV), spatially associated with the zone of degradation of swamp vegetation.http://geology-vestnik.psu.ru/index.php/geology/article/view/432естественное электрическое полеэлектрофильтрационное полеотвалы химических отходовзона инфильтрациизона разгрузкизагрязненные воды
spellingShingle A. P. Gusev
V. L. Molyarenko
A. I. Pavlovsky
I. O. Prilutsky
S. V. Andrushko
Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method
Vestnik Permskogo Universiteta: Seriâ Geologiâ
естественное электрическое поле
электрофильтрационное поле
отвалы химических отходов
зона инфильтрации
зона разгрузки
загрязненные воды
title Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method
title_full Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method
title_fullStr Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method
title_full_unstemmed Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method
title_short Diagnostic Assessment of Polluted Water Leaks from the Site of a Chemical Production Waste Landfill Using the Self-Potential Method
title_sort diagnostic assessment of polluted water leaks from the site of a chemical production waste landfill using the self potential method
topic естественное электрическое поле
электрофильтрационное поле
отвалы химических отходов
зона инфильтрации
зона разгрузки
загрязненные воды
url http://geology-vestnik.psu.ru/index.php/geology/article/view/432
work_keys_str_mv AT apgusev diagnosticassessmentofpollutedwaterleaksfromthesiteofachemicalproductionwastelandfillusingtheselfpotentialmethod
AT vlmolyarenko diagnosticassessmentofpollutedwaterleaksfromthesiteofachemicalproductionwastelandfillusingtheselfpotentialmethod
AT aipavlovsky diagnosticassessmentofpollutedwaterleaksfromthesiteofachemicalproductionwastelandfillusingtheselfpotentialmethod
AT ioprilutsky diagnosticassessmentofpollutedwaterleaksfromthesiteofachemicalproductionwastelandfillusingtheselfpotentialmethod
AT svandrushko diagnosticassessmentofpollutedwaterleaksfromthesiteofachemicalproductionwastelandfillusingtheselfpotentialmethod