Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains

Owing to the outbreak of COVID-19, researchers are exploring methods to prevent contact and non-contact infections that occur via multiple transmission routes. However, studies on preventing infections caused by droplet transmission in public transportation are insufficient. To prevent the spread of...

Full description

Bibliographic Details
Main Authors: Sungho Yun, Jae-Chul Kim
Format: Article
Language:English
Published: MDPI AG 2022-05-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/13/5/829
_version_ 1797501574949371904
author Sungho Yun
Jae-Chul Kim
author_facet Sungho Yun
Jae-Chul Kim
author_sort Sungho Yun
collection DOAJ
description Owing to the outbreak of COVID-19, researchers are exploring methods to prevent contact and non-contact infections that occur via multiple transmission routes. However, studies on preventing infections caused by droplet transmission in public transportation are insufficient. To prevent the spread of infectious diseases, a new ventilation system in railway vehicles must be developed. In this study, a novel vertical drop airflow (VDA) system is proposed to mitigate the effect of droplet transmission in a high-speed train cabin. The droplet transmission route and droplet fate are investigated using three-dimensional fluid dynamics simulations, performed employing the Eulerian–Lagrangian model. Additionally, a porous model is adopted to simulate the effect of close-fitting masks. The results indicate that 120 s after coughing, the decrease in the droplet number in the VDA system is 72.1% of that observed in the conventional system. Moreover, the VDA system effectively suppresses droplet transmission because the maximum droplet travel distances of the VDA systems are 49.9% to 67.0% of those of the conventional systems. Furthermore, the effect of reducing droplet transmission by wearing a close-fitting mask is confirmed in all systems. Thus, the decrease in both droplet number and droplet transmission area in train cabins validate that the proposed VDA system has an effective airflow design to prevent droplet infection.
first_indexed 2024-03-10T03:20:25Z
format Article
id doaj.art-62d2d9d1ce7a4898b4fa31b6688d6e19
institution Directory Open Access Journal
issn 2073-4433
language English
last_indexed 2024-03-10T03:20:25Z
publishDate 2022-05-01
publisher MDPI AG
record_format Article
series Atmosphere
spelling doaj.art-62d2d9d1ce7a4898b4fa31b6688d6e192023-11-23T10:03:27ZengMDPI AGAtmosphere2073-44332022-05-0113582910.3390/atmos13050829Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in TrainsSungho Yun0Jae-Chul Kim1Technical Regulations and Standards Research Department, Korea Railroad Research Institute, Uiwang-si 16105, Gyeonggi-do, KoreaTechnical Regulations and Standards Research Department, Korea Railroad Research Institute, Uiwang-si 16105, Gyeonggi-do, KoreaOwing to the outbreak of COVID-19, researchers are exploring methods to prevent contact and non-contact infections that occur via multiple transmission routes. However, studies on preventing infections caused by droplet transmission in public transportation are insufficient. To prevent the spread of infectious diseases, a new ventilation system in railway vehicles must be developed. In this study, a novel vertical drop airflow (VDA) system is proposed to mitigate the effect of droplet transmission in a high-speed train cabin. The droplet transmission route and droplet fate are investigated using three-dimensional fluid dynamics simulations, performed employing the Eulerian–Lagrangian model. Additionally, a porous model is adopted to simulate the effect of close-fitting masks. The results indicate that 120 s after coughing, the decrease in the droplet number in the VDA system is 72.1% of that observed in the conventional system. Moreover, the VDA system effectively suppresses droplet transmission because the maximum droplet travel distances of the VDA systems are 49.9% to 67.0% of those of the conventional systems. Furthermore, the effect of reducing droplet transmission by wearing a close-fitting mask is confirmed in all systems. Thus, the decrease in both droplet number and droplet transmission area in train cabins validate that the proposed VDA system has an effective airflow design to prevent droplet infection.https://www.mdpi.com/2073-4433/13/5/829droplet transmissionairflow systemmask effectventilation systemhigh-speed trainCOVID-19
spellingShingle Sungho Yun
Jae-Chul Kim
Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains
Atmosphere
droplet transmission
airflow system
mask effect
ventilation system
high-speed train
COVID-19
title Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains
title_full Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains
title_fullStr Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains
title_full_unstemmed Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains
title_short Numerical Evaluation of a Novel Vertical Drop Airflow System to Mitigate Droplet Transmission in Trains
title_sort numerical evaluation of a novel vertical drop airflow system to mitigate droplet transmission in trains
topic droplet transmission
airflow system
mask effect
ventilation system
high-speed train
COVID-19
url https://www.mdpi.com/2073-4433/13/5/829
work_keys_str_mv AT sunghoyun numericalevaluationofanovelverticaldropairflowsystemtomitigatedroplettransmissionintrains
AT jaechulkim numericalevaluationofanovelverticaldropairflowsystemtomitigatedroplettransmissionintrains